Cargando…

Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable

OBJECTIVE: Standard short adrenocorticotropic hormone (ACTH) stimulation test (SST) has traditionally been used for assessing adrenal gland fuction by intravenous (iv) application. However the iv form is not readily available in all countries, including Turkey. The aim of this study was to evaluate...

Descripción completa

Detalles Bibliográficos
Autores principales: Özsu, Elif, Şıklar, Zeynep, Bilici, Esra, Ceran, Ayşegül, Uyanık, Rukiye, Çetin, Tuğba, Aycan, Zehra, Berberoğlu, Merih
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499132/
https://www.ncbi.nlm.nih.gov/pubmed/31842523
http://dx.doi.org/10.4274/jcrpe.galenos.2019.2019.0099
_version_ 1783583653618515968
author Özsu, Elif
Şıklar, Zeynep
Bilici, Esra
Ceran, Ayşegül
Uyanık, Rukiye
Çetin, Tuğba
Aycan, Zehra
Berberoğlu, Merih
author_facet Özsu, Elif
Şıklar, Zeynep
Bilici, Esra
Ceran, Ayşegül
Uyanık, Rukiye
Çetin, Tuğba
Aycan, Zehra
Berberoğlu, Merih
author_sort Özsu, Elif
collection PubMed
description OBJECTIVE: Standard short adrenocorticotropic hormone (ACTH) stimulation test (SST) has traditionally been used for assessing adrenal gland fuction by intravenous (iv) application. However the iv form is not readily available in all countries, including Turkey. The aim of this study was to evaluate the effectiveness of the intramuscular (im) SST. METHODS: Patients underwent im SST with suspected adrenal insufficiency (AI) and hyperandrogenism. The SSTs were done with 250 mcg ACTH (Synacthen Depot ampul, concentration 1 mg/mL). The cases were divided into two groups: suspected AI (group 1 n=87); and hyperandrogenism group (group 2 n=124). Definite AI was defined as peak cortisol <18 μg/dL, suspected AI as a peak cortisol of 18-21 μg/dL and normal result was defined as a peak cortisol ≥22 μg/dL. RESULTS: The mean age of the patients was 11.7±5.2 years. In 164 patients (78%) all of the peak cortisol tests were normal (≥22 mcg/dL). The rates were 64% and 88% in group 1 and 2, respectively. Only 8.5% (n=18) of all cases had an inadequate peak cortisol response of <18 mcg/dL. On follow up, 15 patients whose peak cortisol was <18 mcg/dL needed cortisol therapy. Of all cases 3.3% (n=8) had 17-OHP ≥10 ng/dL. Clinical findings suggestive of non-classical congenital adrenal hyperplasia and/or mutation were found in six of these cases (75%). No local and systemic side effects or allergic reactions were observed in any patient. CONCLUSION: IM ACTH SST is a safe, effective and reliable test in children with suspected AI. There were no local or systemic side effects, supporting the reliability of the im ACTH test.
format Online
Article
Text
id pubmed-7499132
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-74991322020-09-23 Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable Özsu, Elif Şıklar, Zeynep Bilici, Esra Ceran, Ayşegül Uyanık, Rukiye Çetin, Tuğba Aycan, Zehra Berberoğlu, Merih J Clin Res Pediatr Endocrinol Original Article OBJECTIVE: Standard short adrenocorticotropic hormone (ACTH) stimulation test (SST) has traditionally been used for assessing adrenal gland fuction by intravenous (iv) application. However the iv form is not readily available in all countries, including Turkey. The aim of this study was to evaluate the effectiveness of the intramuscular (im) SST. METHODS: Patients underwent im SST with suspected adrenal insufficiency (AI) and hyperandrogenism. The SSTs were done with 250 mcg ACTH (Synacthen Depot ampul, concentration 1 mg/mL). The cases were divided into two groups: suspected AI (group 1 n=87); and hyperandrogenism group (group 2 n=124). Definite AI was defined as peak cortisol <18 μg/dL, suspected AI as a peak cortisol of 18-21 μg/dL and normal result was defined as a peak cortisol ≥22 μg/dL. RESULTS: The mean age of the patients was 11.7±5.2 years. In 164 patients (78%) all of the peak cortisol tests were normal (≥22 mcg/dL). The rates were 64% and 88% in group 1 and 2, respectively. Only 8.5% (n=18) of all cases had an inadequate peak cortisol response of <18 mcg/dL. On follow up, 15 patients whose peak cortisol was <18 mcg/dL needed cortisol therapy. Of all cases 3.3% (n=8) had 17-OHP ≥10 ng/dL. Clinical findings suggestive of non-classical congenital adrenal hyperplasia and/or mutation were found in six of these cases (75%). No local and systemic side effects or allergic reactions were observed in any patient. CONCLUSION: IM ACTH SST is a safe, effective and reliable test in children with suspected AI. There were no local or systemic side effects, supporting the reliability of the im ACTH test. Galenos Publishing 2020-09 2020-09-02 /pmc/articles/PMC7499132/ /pubmed/31842523 http://dx.doi.org/10.4274/jcrpe.galenos.2019.2019.0099 Text en ©Copyright 2020 by Turkish Pediatric Endocrinology and Diabetes Society | The Journal of Clinical Research in Pediatric Endocrinology published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Özsu, Elif
Şıklar, Zeynep
Bilici, Esra
Ceran, Ayşegül
Uyanık, Rukiye
Çetin, Tuğba
Aycan, Zehra
Berberoğlu, Merih
Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title_full Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title_fullStr Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title_full_unstemmed Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title_short Intramuscular Short-term ACTH Test for the Determination of Adrenal Function in Children: Safe, Effective and Reliable
title_sort intramuscular short-term acth test for the determination of adrenal function in children: safe, effective and reliable
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499132/
https://www.ncbi.nlm.nih.gov/pubmed/31842523
http://dx.doi.org/10.4274/jcrpe.galenos.2019.2019.0099
work_keys_str_mv AT ozsuelif intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT sıklarzeynep intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT biliciesra intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT ceranaysegul intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT uyanıkrukiye intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT cetintugba intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT aycanzehra intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable
AT berberoglumerih intramuscularshorttermacthtestforthedeterminationofadrenalfunctioninchildrensafeeffectiveandreliable