Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation
We describe the case of an 81-year-old man with symptomatic severe bicuspid aortic valve stenosis. Transfemoral transcatheter aortic valve implantation was performed with a cerebral embolic protection device. During valve deployment, the 29-mm Evolut PRO prosthesis (Medtronic) popped out 3 times and...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499362/ https://www.ncbi.nlm.nih.gov/pubmed/32995732 http://dx.doi.org/10.1016/j.cjco.2020.05.004 |
_version_ | 1783583699515736064 |
---|---|
author | Cimci, Murat Roffi, Marco Noble, Stephane |
author_facet | Cimci, Murat Roffi, Marco Noble, Stephane |
author_sort | Cimci, Murat |
collection | PubMed |
description | We describe the case of an 81-year-old man with symptomatic severe bicuspid aortic valve stenosis. Transfemoral transcatheter aortic valve implantation was performed with a cerebral embolic protection device. During valve deployment, the 29-mm Evolut PRO prosthesis (Medtronic) popped out 3 times and exchanged for a 34-mm Evolut R. Large valvular debris were captured in the embolic protection device. Subsequently, the patient developed chest pain and electrocardiogram modification. An emergency coronary angiography showed an occlusion of the middle circumflex artery. This case demonstrates technical challenges and possible complications in patients with bicuspid aortic valve stenosis undergoing transcatheter aortic valve implantation. |
format | Online Article Text |
id | pubmed-7499362 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-74993622020-09-28 Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation Cimci, Murat Roffi, Marco Noble, Stephane CJC Open Case Report We describe the case of an 81-year-old man with symptomatic severe bicuspid aortic valve stenosis. Transfemoral transcatheter aortic valve implantation was performed with a cerebral embolic protection device. During valve deployment, the 29-mm Evolut PRO prosthesis (Medtronic) popped out 3 times and exchanged for a 34-mm Evolut R. Large valvular debris were captured in the embolic protection device. Subsequently, the patient developed chest pain and electrocardiogram modification. An emergency coronary angiography showed an occlusion of the middle circumflex artery. This case demonstrates technical challenges and possible complications in patients with bicuspid aortic valve stenosis undergoing transcatheter aortic valve implantation. Elsevier 2020-05-23 /pmc/articles/PMC7499362/ /pubmed/32995732 http://dx.doi.org/10.1016/j.cjco.2020.05.004 Text en © 2020 Canadian Cardiovascular Society. Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Cimci, Murat Roffi, Marco Noble, Stephane Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title | Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title_full | Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title_fullStr | Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title_short | Embolization to Two Different Vascular Territories in a Patient With Bicuspid Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation |
title_sort | embolization to two different vascular territories in a patient with bicuspid aortic stenosis undergoing transcatheter aortic valve implantation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499362/ https://www.ncbi.nlm.nih.gov/pubmed/32995732 http://dx.doi.org/10.1016/j.cjco.2020.05.004 |
work_keys_str_mv | AT cimcimurat embolizationtotwodifferentvascularterritoriesinapatientwithbicuspidaorticstenosisundergoingtranscatheteraorticvalveimplantation AT roffimarco embolizationtotwodifferentvascularterritoriesinapatientwithbicuspidaorticstenosisundergoingtranscatheteraorticvalveimplantation AT noblestephane embolizationtotwodifferentvascularterritoriesinapatientwithbicuspidaorticstenosisundergoingtranscatheteraorticvalveimplantation |