Cargando…

Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement

Remote ambulatory cardiac monitoring (rACM) could identify high-grade atrioventricular block (AVB) before and after transcatheter aortic valve replacement (TAVR). Retrospective analysis of patients undergoing TAVR, with 14-day rACM before and after TAVR, was performed. Of 62 patients undergoing TAVR...

Descripción completa

Detalles Bibliográficos
Autores principales: Winter, Jose L., Healey, Jeffrey S., Sheth, Tej N., Velianou, James L., Schwalm, Jon-David, Smith, Amanda, Reza, Seleman, Natarajan, Madhu K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499381/
https://www.ncbi.nlm.nih.gov/pubmed/32995727
http://dx.doi.org/10.1016/j.cjco.2020.04.006
_version_ 1783583703704797184
author Winter, Jose L.
Healey, Jeffrey S.
Sheth, Tej N.
Velianou, James L.
Schwalm, Jon-David
Smith, Amanda
Reza, Seleman
Natarajan, Madhu K.
author_facet Winter, Jose L.
Healey, Jeffrey S.
Sheth, Tej N.
Velianou, James L.
Schwalm, Jon-David
Smith, Amanda
Reza, Seleman
Natarajan, Madhu K.
author_sort Winter, Jose L.
collection PubMed
description Remote ambulatory cardiac monitoring (rACM) could identify high-grade atrioventricular block (AVB) before and after transcatheter aortic valve replacement (TAVR). Retrospective analysis of patients undergoing TAVR, with 14-day rACM before and after TAVR, was performed. Of 62 patients undergoing TAVR, 41 patients had rACM before TAVR. Three patients had asymptomatic AVB leading to planned pacemaker (PM) implant. After TAVR, 23 patients had rACM, with 1 patient requiring a PM implant for asymptomatic AVB. Five patients underwent unplanned PM after TAVR. Using rACM, almost half of PM implants in TAVR recipients were identified electively. High-grade AVB requiring PM was identified in nearly 10% of patients before TAVR.
format Online
Article
Text
id pubmed-7499381
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74993812020-09-28 Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement Winter, Jose L. Healey, Jeffrey S. Sheth, Tej N. Velianou, James L. Schwalm, Jon-David Smith, Amanda Reza, Seleman Natarajan, Madhu K. CJC Open Emerging Evidence Remote ambulatory cardiac monitoring (rACM) could identify high-grade atrioventricular block (AVB) before and after transcatheter aortic valve replacement (TAVR). Retrospective analysis of patients undergoing TAVR, with 14-day rACM before and after TAVR, was performed. Of 62 patients undergoing TAVR, 41 patients had rACM before TAVR. Three patients had asymptomatic AVB leading to planned pacemaker (PM) implant. After TAVR, 23 patients had rACM, with 1 patient requiring a PM implant for asymptomatic AVB. Five patients underwent unplanned PM after TAVR. Using rACM, almost half of PM implants in TAVR recipients were identified electively. High-grade AVB requiring PM was identified in nearly 10% of patients before TAVR. Elsevier 2020-04-25 /pmc/articles/PMC7499381/ /pubmed/32995727 http://dx.doi.org/10.1016/j.cjco.2020.04.006 Text en © 2020 Canadian Cardiovascular Society. Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Emerging Evidence
Winter, Jose L.
Healey, Jeffrey S.
Sheth, Tej N.
Velianou, James L.
Schwalm, Jon-David
Smith, Amanda
Reza, Seleman
Natarajan, Madhu K.
Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title_full Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title_fullStr Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title_full_unstemmed Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title_short Remote Ambulatory Cardiac Monitoring Before and After Transcatheter Aortic Valve Replacement
title_sort remote ambulatory cardiac monitoring before and after transcatheter aortic valve replacement
topic Emerging Evidence
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7499381/
https://www.ncbi.nlm.nih.gov/pubmed/32995727
http://dx.doi.org/10.1016/j.cjco.2020.04.006
work_keys_str_mv AT winterjosel remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT healeyjeffreys remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT shethtejn remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT velianoujamesl remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT schwalmjondavid remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT smithamanda remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT rezaseleman remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement
AT natarajanmadhuk remoteambulatorycardiacmonitoringbeforeandaftertranscatheteraorticvalvereplacement