Cargando…
Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting
Gait disability in people with progressive multiple sclerosis (MS) is difficult to quantify using existing clinical tools. This study aims to identify reliable and objective gait-based biomarkers to monitor progressive multiple sclerosis (MS) in clinical settings. During routine clinical visits, 57...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501113/ https://www.ncbi.nlm.nih.gov/pubmed/32468119 http://dx.doi.org/10.1007/s00415-020-09928-8 |
_version_ | 1783583988573536256 |
---|---|
author | Angelini, Lorenza Hodgkinson, William Smith, Craig Dodd, Jessie Moorman Sharrack, Basil Mazzà, Claudia Paling, David |
author_facet | Angelini, Lorenza Hodgkinson, William Smith, Craig Dodd, Jessie Moorman Sharrack, Basil Mazzà, Claudia Paling, David |
author_sort | Angelini, Lorenza |
collection | PubMed |
description | Gait disability in people with progressive multiple sclerosis (MS) is difficult to quantify using existing clinical tools. This study aims to identify reliable and objective gait-based biomarkers to monitor progressive multiple sclerosis (MS) in clinical settings. During routine clinical visits, 57 people with secondary progressive MS and 24 healthy controls walked for 6 minutes wearing three inertial motion sensors. Fifteen gait measures were computed from the sensor data and tested for between-session reliability, for differences between controls and people with moderate and severe MS disability, and for correlation with Expanded Disability Status Scale (EDSS) scores. The majority of gait measures showed good to excellent between-session reliability when assessed in a subgroup of 23 healthy controls and 25 people with MS. These measures showed that people with MS walked with significantly longer step and stride durations, reduced step and stride regularity, and experienced difficulties in controlling and maintaining a stable walk when compared to controls. These abnormalities significantly increased in people with a higher level of disability and correlated with their EDSS scores. Reliable and objective gait-based biomarkers using wearable sensors have been identified. These biomarkers may allow clinicians to quantify clinically relevant alterations in gait in people with progressive MS within the context of regular clinical visits. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00415-020-09928-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-7501113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-75011132020-10-01 Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting Angelini, Lorenza Hodgkinson, William Smith, Craig Dodd, Jessie Moorman Sharrack, Basil Mazzà, Claudia Paling, David J Neurol Original Communication Gait disability in people with progressive multiple sclerosis (MS) is difficult to quantify using existing clinical tools. This study aims to identify reliable and objective gait-based biomarkers to monitor progressive multiple sclerosis (MS) in clinical settings. During routine clinical visits, 57 people with secondary progressive MS and 24 healthy controls walked for 6 minutes wearing three inertial motion sensors. Fifteen gait measures were computed from the sensor data and tested for between-session reliability, for differences between controls and people with moderate and severe MS disability, and for correlation with Expanded Disability Status Scale (EDSS) scores. The majority of gait measures showed good to excellent between-session reliability when assessed in a subgroup of 23 healthy controls and 25 people with MS. These measures showed that people with MS walked with significantly longer step and stride durations, reduced step and stride regularity, and experienced difficulties in controlling and maintaining a stable walk when compared to controls. These abnormalities significantly increased in people with a higher level of disability and correlated with their EDSS scores. Reliable and objective gait-based biomarkers using wearable sensors have been identified. These biomarkers may allow clinicians to quantify clinically relevant alterations in gait in people with progressive MS within the context of regular clinical visits. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00415-020-09928-8) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-05-28 2020 /pmc/articles/PMC7501113/ /pubmed/32468119 http://dx.doi.org/10.1007/s00415-020-09928-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Communication Angelini, Lorenza Hodgkinson, William Smith, Craig Dodd, Jessie Moorman Sharrack, Basil Mazzà, Claudia Paling, David Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title | Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title_full | Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title_fullStr | Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title_full_unstemmed | Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title_short | Wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
title_sort | wearable sensors can reliably quantify gait alterations associated with disability in people with progressive multiple sclerosis in a clinical setting |
topic | Original Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501113/ https://www.ncbi.nlm.nih.gov/pubmed/32468119 http://dx.doi.org/10.1007/s00415-020-09928-8 |
work_keys_str_mv | AT angelinilorenza wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT hodgkinsonwilliam wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT smithcraig wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT doddjessiemoorman wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT sharrackbasil wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT mazzaclaudia wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting AT palingdavid wearablesensorscanreliablyquantifygaitalterationsassociatedwithdisabilityinpeoplewithprogressivemultiplesclerosisinaclinicalsetting |