Cargando…

Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report

BACKGROUND: In cardiac resynchronization therapy, left ventricular (LV) lead placement at the desired position may be difficult due to abnormal coronary sinus (CS) and lateral vein anatomy. We present a case with difficult anatomy in which we used ‘an indigenous snare’ made from hardware used for co...

Descripción completa

Detalles Bibliográficos
Autores principales: Reddy, Muni Venkatesa, Deshpande, Saurabh Ajit, Roul, Shishir Kumar, Udyavar, Ameya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501892/
https://www.ncbi.nlm.nih.gov/pubmed/32974436
http://dx.doi.org/10.1093/ehjcr/ytaa114
_version_ 1783584122657046528
author Reddy, Muni Venkatesa
Deshpande, Saurabh Ajit
Roul, Shishir Kumar
Udyavar, Ameya
author_facet Reddy, Muni Venkatesa
Deshpande, Saurabh Ajit
Roul, Shishir Kumar
Udyavar, Ameya
author_sort Reddy, Muni Venkatesa
collection PubMed
description BACKGROUND: In cardiac resynchronization therapy, left ventricular (LV) lead placement at the desired position may be difficult due to abnormal coronary sinus (CS) and lateral vein anatomy. We present a case with difficult anatomy in which we used ‘an indigenous snare’ made from hardware used for coronary angioplasty procedures, which is available in any cardiac catheterization laboratory. CASE SUMMARY: A 52-year-old man presented with dyspnoea due to chronic heart failure was evaluated for cardiac resynchronization therapy. The LV lead was difficult to advance into the only target lateral branch of the CS due to a combination of angulation and proximal stenosis. Balloon dilation was tried first, but we failed to track the LV lead. We formed a venovenous loop, advancing the coronary guidewire 0.014″ into the posterolateral vein; subsequently into the middle cardiac vein via a collateral. The wire was advanced into the CS and then to superior vena cava. The guidewire then snared through the same left subclavian vein and exteriorized by using indigenous snare. Over this loop, the LV lead of the cardiac resynchronization therapy with defibrillator device was implanted successfully. DISCUSSION: We have used the snare technique, with the use of a snare prepared from a coronary guidewire. Use of such an indigenous snare has not been described before in the literature. The hardware used in this case is routinely used for coronary angioplasty procedures in all catheterization labs. The importance of our case is that no special hardware like dedicated snare was required to negotiate the LV lead at its desired location.
format Online
Article
Text
id pubmed-7501892
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-75018922020-09-23 Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report Reddy, Muni Venkatesa Deshpande, Saurabh Ajit Roul, Shishir Kumar Udyavar, Ameya Eur Heart J Case Rep Case Reports BACKGROUND: In cardiac resynchronization therapy, left ventricular (LV) lead placement at the desired position may be difficult due to abnormal coronary sinus (CS) and lateral vein anatomy. We present a case with difficult anatomy in which we used ‘an indigenous snare’ made from hardware used for coronary angioplasty procedures, which is available in any cardiac catheterization laboratory. CASE SUMMARY: A 52-year-old man presented with dyspnoea due to chronic heart failure was evaluated for cardiac resynchronization therapy. The LV lead was difficult to advance into the only target lateral branch of the CS due to a combination of angulation and proximal stenosis. Balloon dilation was tried first, but we failed to track the LV lead. We formed a venovenous loop, advancing the coronary guidewire 0.014″ into the posterolateral vein; subsequently into the middle cardiac vein via a collateral. The wire was advanced into the CS and then to superior vena cava. The guidewire then snared through the same left subclavian vein and exteriorized by using indigenous snare. Over this loop, the LV lead of the cardiac resynchronization therapy with defibrillator device was implanted successfully. DISCUSSION: We have used the snare technique, with the use of a snare prepared from a coronary guidewire. Use of such an indigenous snare has not been described before in the literature. The hardware used in this case is routinely used for coronary angioplasty procedures in all catheterization labs. The importance of our case is that no special hardware like dedicated snare was required to negotiate the LV lead at its desired location. Oxford University Press 2020-05-26 /pmc/articles/PMC7501892/ /pubmed/32974436 http://dx.doi.org/10.1093/ehjcr/ytaa114 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Reddy, Muni Venkatesa
Deshpande, Saurabh Ajit
Roul, Shishir Kumar
Udyavar, Ameya
Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title_full Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title_fullStr Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title_full_unstemmed Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title_short Successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
title_sort successful use of venovenous snare to fix the wire in a collateral vein for proper placement of the left ventricular lead during cardiac resynchronization therapy: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501892/
https://www.ncbi.nlm.nih.gov/pubmed/32974436
http://dx.doi.org/10.1093/ehjcr/ytaa114
work_keys_str_mv AT reddymunivenkatesa successfuluseofvenovenoussnaretofixthewireinacollateralveinforproperplacementoftheleftventricularleadduringcardiacresynchronizationtherapyacasereport
AT deshpandesaurabhajit successfuluseofvenovenoussnaretofixthewireinacollateralveinforproperplacementoftheleftventricularleadduringcardiacresynchronizationtherapyacasereport
AT roulshishirkumar successfuluseofvenovenoussnaretofixthewireinacollateralveinforproperplacementoftheleftventricularleadduringcardiacresynchronizationtherapyacasereport
AT udyavarameya successfuluseofvenovenoussnaretofixthewireinacollateralveinforproperplacementoftheleftventricularleadduringcardiacresynchronizationtherapyacasereport