Cargando…

High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report

BACKGROUND : Percutaneous closure of patent foramen ovale (PFO) is recommended for patients presenting with PFO-related stroke. Acute high-grade conduction disturbances occurring during PFO closure procedure have not been previously reported. CASE SUMMARY : We describe for the first time a case of r...

Descripción completa

Detalles Bibliográficos
Autores principales: Kibler, Marion, Marzak, Halim, Jesel, Laurence, Ohlmann, Patrick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501918/
https://www.ncbi.nlm.nih.gov/pubmed/32974462
http://dx.doi.org/10.1093/ehjcr/ytaa141
_version_ 1783584125945380864
author Kibler, Marion
Marzak, Halim
Jesel, Laurence
Ohlmann, Patrick
author_facet Kibler, Marion
Marzak, Halim
Jesel, Laurence
Ohlmann, Patrick
author_sort Kibler, Marion
collection PubMed
description BACKGROUND : Percutaneous closure of patent foramen ovale (PFO) is recommended for patients presenting with PFO-related stroke. Acute high-grade conduction disturbances occurring during PFO closure procedure have not been previously reported. CASE SUMMARY : We describe for the first time a case of reversible complete atrioventricular block which occurred during closure of a PFO. DISCUSSION : We hypothesized that the block was the result of atrioventricular node compression—likely caused by the right-atrial disc of the 35-mm PFO closure device. We suggest implanting smaller devices in order to prevent atrioventricular conduction disturbances.
format Online
Article
Text
id pubmed-7501918
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-75019182020-09-23 High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report Kibler, Marion Marzak, Halim Jesel, Laurence Ohlmann, Patrick Eur Heart J Case Rep Case Reports BACKGROUND : Percutaneous closure of patent foramen ovale (PFO) is recommended for patients presenting with PFO-related stroke. Acute high-grade conduction disturbances occurring during PFO closure procedure have not been previously reported. CASE SUMMARY : We describe for the first time a case of reversible complete atrioventricular block which occurred during closure of a PFO. DISCUSSION : We hypothesized that the block was the result of atrioventricular node compression—likely caused by the right-atrial disc of the 35-mm PFO closure device. We suggest implanting smaller devices in order to prevent atrioventricular conduction disturbances. Oxford University Press 2020-06-25 /pmc/articles/PMC7501918/ /pubmed/32974462 http://dx.doi.org/10.1093/ehjcr/ytaa141 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Kibler, Marion
Marzak, Halim
Jesel, Laurence
Ohlmann, Patrick
High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title_full High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title_fullStr High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title_full_unstemmed High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title_short High-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
title_sort high-grade atrioventricular block occurring during percutaneous closure of patent foramen ovale: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7501918/
https://www.ncbi.nlm.nih.gov/pubmed/32974462
http://dx.doi.org/10.1093/ehjcr/ytaa141
work_keys_str_mv AT kiblermarion highgradeatrioventricularblockoccurringduringpercutaneousclosureofpatentforamenovaleacasereport
AT marzakhalim highgradeatrioventricularblockoccurringduringpercutaneousclosureofpatentforamenovaleacasereport
AT jesellaurence highgradeatrioventricularblockoccurringduringpercutaneousclosureofpatentforamenovaleacasereport
AT ohlmannpatrick highgradeatrioventricularblockoccurringduringpercutaneousclosureofpatentforamenovaleacasereport