Cargando…

Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature

OBJECTIVE: To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. METHODS: Review of existing literature and description of per...

Descripción completa

Detalles Bibliográficos
Autores principales: Frost, Ariel, Mirza, Natasha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502009/
https://www.ncbi.nlm.nih.gov/pubmed/32983585
http://dx.doi.org/10.1016/j.wjorl.2020.08.001
_version_ 1783584142405926912
author Frost, Ariel
Mirza, Natasha
author_facet Frost, Ariel
Mirza, Natasha
author_sort Frost, Ariel
collection PubMed
description OBJECTIVE: To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. METHODS: Review of existing literature and description of personal experience with unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. RESULTS: Review of existing literature found no prior reported cases of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Risk factors for implant extrusion include the pressure of the implant on insertion and the inability to secure the implant. Cases of implant extrusion can be managed operatively via an endoscopic or via an external open approach. CONCLUSION: This is the first reported case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Careful consideration should be given in revision medialization thyroplasty as additional implant material may cause increased pressure, a risk factor for implant extrusion.
format Online
Article
Text
id pubmed-7502009
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-75020092020-09-21 Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature Frost, Ariel Mirza, Natasha World J Otorhinolaryngol Head Neck Surg Review Articles OBJECTIVE: To review current literature and experience with Gore‐TexⓇ implant extrusion following medialization thyroplasty, as well as to report the unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. METHODS: Review of existing literature and description of personal experience with unique case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. RESULTS: Review of existing literature found no prior reported cases of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Risk factors for implant extrusion include the pressure of the implant on insertion and the inability to secure the implant. Cases of implant extrusion can be managed operatively via an endoscopic or via an external open approach. CONCLUSION: This is the first reported case of Gore‐TexⓇ implant extrusion following revision medialization thyroplasty. Careful consideration should be given in revision medialization thyroplasty as additional implant material may cause increased pressure, a risk factor for implant extrusion. John Wiley and Sons Inc. 2022-04-18 /pmc/articles/PMC7502009/ /pubmed/32983585 http://dx.doi.org/10.1016/j.wjorl.2020.08.001 Text en © 2022 The Authors. World Journal of Otorhinolaryngology ‐ Head and Neck Surgery published by John Wiley & Sons Ltd on behalf of Chinese Medical Association. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Review Articles
Frost, Ariel
Mirza, Natasha
Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title_full Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title_fullStr Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title_full_unstemmed Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title_short Gore‐Tex implant extrusion following revision medialization thyroplasty: Case report and review of the literature
title_sort gore‐tex implant extrusion following revision medialization thyroplasty: case report and review of the literature
topic Review Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502009/
https://www.ncbi.nlm.nih.gov/pubmed/32983585
http://dx.doi.org/10.1016/j.wjorl.2020.08.001
work_keys_str_mv AT frostariel goreteximplantextrusionfollowingrevisionmedializationthyroplastycasereportandreviewoftheliterature
AT mirzanatasha goreteximplantextrusionfollowingrevisionmedializationthyroplastycasereportandreviewoftheliterature