Cargando…

Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses

PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists o...

Descripción completa

Detalles Bibliográficos
Autores principales: Lubiński, Wojciech, Podborączyńska-Jodko, Karolina, Kirkiewicz, Marta, Mularczyk, Maciej, Post, Michał
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502443/
https://www.ncbi.nlm.nih.gov/pubmed/32488596
http://dx.doi.org/10.1007/s10792-020-01435-z
_version_ 1783584226089631744
author Lubiński, Wojciech
Podborączyńska-Jodko, Karolina
Kirkiewicz, Marta
Mularczyk, Maciej
Post, Michał
author_facet Lubiński, Wojciech
Podborączyńska-Jodko, Karolina
Kirkiewicz, Marta
Mularczyk, Maciej
Post, Michał
author_sort Lubiński, Wojciech
collection PubMed
description PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists of 20 patients (40 eyes). At 1 year postoperatively, the following parameters were analysed: binocular uncorrected visual acuity (log MAR): for distance (UDVA) at 4 m, for intermediate distances (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire modified VFQ-25), photopic phenomena and postoperative complications. RESULTS: In the AtLisa tri 839 MP group, the mean binocular UNVA and UIVA were significantly better than in the Symfony group (UNVA: − 0.01 ± 0.04 vs. 0.21 ± 0.15; p = 0.000; 60 cm UIVA: − 0.01 ± 0.04 vs. 0.09 ± 0.09, p = 0.001; 70 cm UIVA − 0.05 ± 0.06 vs. 0.11 ± 0.08, p = 0.002; 80 cm UIVA − 0.01 ± 0.06 vs. 0.15 ± 0.08, p = 0.019). There were no significant between-group differences in the mean binocular UDVA and CS, with one exception: the mean binocular distance CS (18 cpd) under mesopic conditions was significantly better in the Symfony group than in the AtLisa tri 839 MP group (1.39 ± 0.22 vs. 1.17 ± 0.27; p = 0.015). The defocus curve analysis revealed significant between-group differences at vergences of 2.0 to − 4.0 D (p < 0.05), except for 2.0, 1.0, 0 and − 1.5. All subjects in AtLisa tri 839 MP group and 18 subjects (90%) in Symfony group were spectacle independent. Patients from both groups highly rated their overall vision quality in the VFQ-25 (1.67 ± 0.47 vs. 1.85 ± 0.5 in the Symfony and AtLisa tri 839 MP group, respectively, p = NS). The scores for daytime driving (1.00 ± 0.00 vs. 1.21 ± 0.36; p = 0.002), night driving (1.57 ± 0.55 vs. 2.13 ± 1.15; p = 0.027) and difficult situation driving (1.14 ± 0.31 vs. 1.53 ± 0.56; p = 0.049) were significantly better in the AtLisa tri 839 MP group than in the Symfony group. The incidence and perception level of halo and glare were significantly reduced (p = 0.00) in the Symfony group as compared to the AtLisa tri 839 MP group. The postoperative course was uneventful in all subjects. CONCLUSIONS: Visual outcomes achieved with both IOLs are comparable. In both groups, 90% of patients achieved spectacle independence. Whereas the AtLisa tri 839 MP IOL implantation was associated with slightly better intermediate distance VA and significantly better near VA, photic phenomena were less perceived by patients with Symfony IOLs.
format Online
Article
Text
id pubmed-7502443
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-75024432020-10-01 Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses Lubiński, Wojciech Podborączyńska-Jodko, Karolina Kirkiewicz, Marta Mularczyk, Maciej Post, Michał Int Ophthalmol Original Paper PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists of 20 patients (40 eyes). At 1 year postoperatively, the following parameters were analysed: binocular uncorrected visual acuity (log MAR): for distance (UDVA) at 4 m, for intermediate distances (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire modified VFQ-25), photopic phenomena and postoperative complications. RESULTS: In the AtLisa tri 839 MP group, the mean binocular UNVA and UIVA were significantly better than in the Symfony group (UNVA: − 0.01 ± 0.04 vs. 0.21 ± 0.15; p = 0.000; 60 cm UIVA: − 0.01 ± 0.04 vs. 0.09 ± 0.09, p = 0.001; 70 cm UIVA − 0.05 ± 0.06 vs. 0.11 ± 0.08, p = 0.002; 80 cm UIVA − 0.01 ± 0.06 vs. 0.15 ± 0.08, p = 0.019). There were no significant between-group differences in the mean binocular UDVA and CS, with one exception: the mean binocular distance CS (18 cpd) under mesopic conditions was significantly better in the Symfony group than in the AtLisa tri 839 MP group (1.39 ± 0.22 vs. 1.17 ± 0.27; p = 0.015). The defocus curve analysis revealed significant between-group differences at vergences of 2.0 to − 4.0 D (p < 0.05), except for 2.0, 1.0, 0 and − 1.5. All subjects in AtLisa tri 839 MP group and 18 subjects (90%) in Symfony group were spectacle independent. Patients from both groups highly rated their overall vision quality in the VFQ-25 (1.67 ± 0.47 vs. 1.85 ± 0.5 in the Symfony and AtLisa tri 839 MP group, respectively, p = NS). The scores for daytime driving (1.00 ± 0.00 vs. 1.21 ± 0.36; p = 0.002), night driving (1.57 ± 0.55 vs. 2.13 ± 1.15; p = 0.027) and difficult situation driving (1.14 ± 0.31 vs. 1.53 ± 0.56; p = 0.049) were significantly better in the AtLisa tri 839 MP group than in the Symfony group. The incidence and perception level of halo and glare were significantly reduced (p = 0.00) in the Symfony group as compared to the AtLisa tri 839 MP group. The postoperative course was uneventful in all subjects. CONCLUSIONS: Visual outcomes achieved with both IOLs are comparable. In both groups, 90% of patients achieved spectacle independence. Whereas the AtLisa tri 839 MP IOL implantation was associated with slightly better intermediate distance VA and significantly better near VA, photic phenomena were less perceived by patients with Symfony IOLs. Springer Netherlands 2020-06-02 2020 /pmc/articles/PMC7502443/ /pubmed/32488596 http://dx.doi.org/10.1007/s10792-020-01435-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Paper
Lubiński, Wojciech
Podborączyńska-Jodko, Karolina
Kirkiewicz, Marta
Mularczyk, Maciej
Post, Michał
Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title_full Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title_fullStr Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title_full_unstemmed Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title_short Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
title_sort comparison of visual outcomes after implantation of atlisa tri 839 mp and symfony intraocular lenses
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502443/
https://www.ncbi.nlm.nih.gov/pubmed/32488596
http://dx.doi.org/10.1007/s10792-020-01435-z
work_keys_str_mv AT lubinskiwojciech comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses
AT podboraczynskajodkokarolina comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses
AT kirkiewiczmarta comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses
AT mularczykmaciej comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses
AT postmichał comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses