Cargando…
Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses
PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502443/ https://www.ncbi.nlm.nih.gov/pubmed/32488596 http://dx.doi.org/10.1007/s10792-020-01435-z |
_version_ | 1783584226089631744 |
---|---|
author | Lubiński, Wojciech Podborączyńska-Jodko, Karolina Kirkiewicz, Marta Mularczyk, Maciej Post, Michał |
author_facet | Lubiński, Wojciech Podborączyńska-Jodko, Karolina Kirkiewicz, Marta Mularczyk, Maciej Post, Michał |
author_sort | Lubiński, Wojciech |
collection | PubMed |
description | PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists of 20 patients (40 eyes). At 1 year postoperatively, the following parameters were analysed: binocular uncorrected visual acuity (log MAR): for distance (UDVA) at 4 m, for intermediate distances (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire modified VFQ-25), photopic phenomena and postoperative complications. RESULTS: In the AtLisa tri 839 MP group, the mean binocular UNVA and UIVA were significantly better than in the Symfony group (UNVA: − 0.01 ± 0.04 vs. 0.21 ± 0.15; p = 0.000; 60 cm UIVA: − 0.01 ± 0.04 vs. 0.09 ± 0.09, p = 0.001; 70 cm UIVA − 0.05 ± 0.06 vs. 0.11 ± 0.08, p = 0.002; 80 cm UIVA − 0.01 ± 0.06 vs. 0.15 ± 0.08, p = 0.019). There were no significant between-group differences in the mean binocular UDVA and CS, with one exception: the mean binocular distance CS (18 cpd) under mesopic conditions was significantly better in the Symfony group than in the AtLisa tri 839 MP group (1.39 ± 0.22 vs. 1.17 ± 0.27; p = 0.015). The defocus curve analysis revealed significant between-group differences at vergences of 2.0 to − 4.0 D (p < 0.05), except for 2.0, 1.0, 0 and − 1.5. All subjects in AtLisa tri 839 MP group and 18 subjects (90%) in Symfony group were spectacle independent. Patients from both groups highly rated their overall vision quality in the VFQ-25 (1.67 ± 0.47 vs. 1.85 ± 0.5 in the Symfony and AtLisa tri 839 MP group, respectively, p = NS). The scores for daytime driving (1.00 ± 0.00 vs. 1.21 ± 0.36; p = 0.002), night driving (1.57 ± 0.55 vs. 2.13 ± 1.15; p = 0.027) and difficult situation driving (1.14 ± 0.31 vs. 1.53 ± 0.56; p = 0.049) were significantly better in the AtLisa tri 839 MP group than in the Symfony group. The incidence and perception level of halo and glare were significantly reduced (p = 0.00) in the Symfony group as compared to the AtLisa tri 839 MP group. The postoperative course was uneventful in all subjects. CONCLUSIONS: Visual outcomes achieved with both IOLs are comparable. In both groups, 90% of patients achieved spectacle independence. Whereas the AtLisa tri 839 MP IOL implantation was associated with slightly better intermediate distance VA and significantly better near VA, photic phenomena were less perceived by patients with Symfony IOLs. |
format | Online Article Text |
id | pubmed-7502443 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-75024432020-10-01 Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses Lubiński, Wojciech Podborączyńska-Jodko, Karolina Kirkiewicz, Marta Mularczyk, Maciej Post, Michał Int Ophthalmol Original Paper PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists of 20 patients (40 eyes). At 1 year postoperatively, the following parameters were analysed: binocular uncorrected visual acuity (log MAR): for distance (UDVA) at 4 m, for intermediate distances (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire modified VFQ-25), photopic phenomena and postoperative complications. RESULTS: In the AtLisa tri 839 MP group, the mean binocular UNVA and UIVA were significantly better than in the Symfony group (UNVA: − 0.01 ± 0.04 vs. 0.21 ± 0.15; p = 0.000; 60 cm UIVA: − 0.01 ± 0.04 vs. 0.09 ± 0.09, p = 0.001; 70 cm UIVA − 0.05 ± 0.06 vs. 0.11 ± 0.08, p = 0.002; 80 cm UIVA − 0.01 ± 0.06 vs. 0.15 ± 0.08, p = 0.019). There were no significant between-group differences in the mean binocular UDVA and CS, with one exception: the mean binocular distance CS (18 cpd) under mesopic conditions was significantly better in the Symfony group than in the AtLisa tri 839 MP group (1.39 ± 0.22 vs. 1.17 ± 0.27; p = 0.015). The defocus curve analysis revealed significant between-group differences at vergences of 2.0 to − 4.0 D (p < 0.05), except for 2.0, 1.0, 0 and − 1.5. All subjects in AtLisa tri 839 MP group and 18 subjects (90%) in Symfony group were spectacle independent. Patients from both groups highly rated their overall vision quality in the VFQ-25 (1.67 ± 0.47 vs. 1.85 ± 0.5 in the Symfony and AtLisa tri 839 MP group, respectively, p = NS). The scores for daytime driving (1.00 ± 0.00 vs. 1.21 ± 0.36; p = 0.002), night driving (1.57 ± 0.55 vs. 2.13 ± 1.15; p = 0.027) and difficult situation driving (1.14 ± 0.31 vs. 1.53 ± 0.56; p = 0.049) were significantly better in the AtLisa tri 839 MP group than in the Symfony group. The incidence and perception level of halo and glare were significantly reduced (p = 0.00) in the Symfony group as compared to the AtLisa tri 839 MP group. The postoperative course was uneventful in all subjects. CONCLUSIONS: Visual outcomes achieved with both IOLs are comparable. In both groups, 90% of patients achieved spectacle independence. Whereas the AtLisa tri 839 MP IOL implantation was associated with slightly better intermediate distance VA and significantly better near VA, photic phenomena were less perceived by patients with Symfony IOLs. Springer Netherlands 2020-06-02 2020 /pmc/articles/PMC7502443/ /pubmed/32488596 http://dx.doi.org/10.1007/s10792-020-01435-z Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Paper Lubiński, Wojciech Podborączyńska-Jodko, Karolina Kirkiewicz, Marta Mularczyk, Maciej Post, Michał Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title | Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title_full | Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title_fullStr | Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title_full_unstemmed | Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title_short | Comparison of visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses |
title_sort | comparison of visual outcomes after implantation of atlisa tri 839 mp and symfony intraocular lenses |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502443/ https://www.ncbi.nlm.nih.gov/pubmed/32488596 http://dx.doi.org/10.1007/s10792-020-01435-z |
work_keys_str_mv | AT lubinskiwojciech comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses AT podboraczynskajodkokarolina comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses AT kirkiewiczmarta comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses AT mularczykmaciej comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses AT postmichał comparisonofvisualoutcomesafterimplantationofatlisatri839mpandsymfonyintraocularlenses |