Cargando…

Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema

BACKGROUND AND PURPOSE: In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared...

Descripción completa

Detalles Bibliográficos
Autores principales: van Dijk, Marlies, Klooster, Karin, Hartman, Jorine E., ten Hacken, Nick H. T., Slebos, Dirk-Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502448/
https://www.ncbi.nlm.nih.gov/pubmed/32710165
http://dx.doi.org/10.1007/s00408-020-00382-x
_version_ 1783584227319611392
author van Dijk, Marlies
Klooster, Karin
Hartman, Jorine E.
ten Hacken, Nick H. T.
Slebos, Dirk-Jan
author_facet van Dijk, Marlies
Klooster, Karin
Hartman, Jorine E.
ten Hacken, Nick H. T.
Slebos, Dirk-Jan
author_sort van Dijk, Marlies
collection PubMed
description BACKGROUND AND PURPOSE: In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared to standard of care (SoC) on dynamic hyperinflation. METHODS: Dynamic hyperinflation was induced by a manually paced tachypnea test (MPT) and was defined by change in inspiratory capacity (IC) measured before and after MPT. Static and dynamic hyperinflation measurements were performed both at baseline and 6 months after BLVR with endobronchial valves or coils (treatment group) or SoC (control group). RESULTS: Eighteen patients underwent BLVR (78% female, 57 (43–67) years, FEV(1) 25(18–37) %predicted, residual volume 231 (182–376) %predicted). Thirteen patients received SoC (100% female, 59 (44–74) years, FEV(1) 25 (19–37) %predicted, residual volume 225 (152–279) %predicted. The 6 months median change in dynamic hyperinflation in the treatment group was: + 225 ml (range − 113 to + 803) (p < 0.01) vs 0 ml (− 1067 to + 500) in the control group (p = 0.422). An increase in dynamic hyperinflation was significantly associated with a decrease in residual volume (r = − 0.439, p < 0.01). CONCLUSION: Bronchoscopic lung volume reduction increases the ability for dynamic hyperinflation in patients with severe emphysema. We propose this is a consequence of improved static hyperinflation.
format Online
Article
Text
id pubmed-7502448
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-75024482020-10-01 Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema van Dijk, Marlies Klooster, Karin Hartman, Jorine E. ten Hacken, Nick H. T. Slebos, Dirk-Jan Lung Bronchoscopic Lung Volume Reduction BACKGROUND AND PURPOSE: In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared to standard of care (SoC) on dynamic hyperinflation. METHODS: Dynamic hyperinflation was induced by a manually paced tachypnea test (MPT) and was defined by change in inspiratory capacity (IC) measured before and after MPT. Static and dynamic hyperinflation measurements were performed both at baseline and 6 months after BLVR with endobronchial valves or coils (treatment group) or SoC (control group). RESULTS: Eighteen patients underwent BLVR (78% female, 57 (43–67) years, FEV(1) 25(18–37) %predicted, residual volume 231 (182–376) %predicted). Thirteen patients received SoC (100% female, 59 (44–74) years, FEV(1) 25 (19–37) %predicted, residual volume 225 (152–279) %predicted. The 6 months median change in dynamic hyperinflation in the treatment group was: + 225 ml (range − 113 to + 803) (p < 0.01) vs 0 ml (− 1067 to + 500) in the control group (p = 0.422). An increase in dynamic hyperinflation was significantly associated with a decrease in residual volume (r = − 0.439, p < 0.01). CONCLUSION: Bronchoscopic lung volume reduction increases the ability for dynamic hyperinflation in patients with severe emphysema. We propose this is a consequence of improved static hyperinflation. Springer US 2020-07-24 2020 /pmc/articles/PMC7502448/ /pubmed/32710165 http://dx.doi.org/10.1007/s00408-020-00382-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Bronchoscopic Lung Volume Reduction
van Dijk, Marlies
Klooster, Karin
Hartman, Jorine E.
ten Hacken, Nick H. T.
Slebos, Dirk-Jan
Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title_full Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title_fullStr Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title_full_unstemmed Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title_short Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
title_sort change in dynamic hyperinflation after bronchoscopic lung volume reduction in patients with emphysema
topic Bronchoscopic Lung Volume Reduction
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502448/
https://www.ncbi.nlm.nih.gov/pubmed/32710165
http://dx.doi.org/10.1007/s00408-020-00382-x
work_keys_str_mv AT vandijkmarlies changeindynamichyperinflationafterbronchoscopiclungvolumereductioninpatientswithemphysema
AT kloosterkarin changeindynamichyperinflationafterbronchoscopiclungvolumereductioninpatientswithemphysema
AT hartmanjorinee changeindynamichyperinflationafterbronchoscopiclungvolumereductioninpatientswithemphysema
AT tenhackennickht changeindynamichyperinflationafterbronchoscopiclungvolumereductioninpatientswithemphysema
AT slebosdirkjan changeindynamichyperinflationafterbronchoscopiclungvolumereductioninpatientswithemphysema