Cargando…

Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study

Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences...

Descripción completa

Detalles Bibliográficos
Autores principales: Leutritz, Tobias, Seif, Maryam, Helms, Gunther, Samson, Rebecca S, Curt, Armin, Freund, Patrick, Weiskopf, Nikolaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502832/
https://www.ncbi.nlm.nih.gov/pubmed/32639104
http://dx.doi.org/10.1002/hbm.25122
_version_ 1783584273015504896
author Leutritz, Tobias
Seif, Maryam
Helms, Gunther
Samson, Rebecca S
Curt, Armin
Freund, Patrick
Weiskopf, Nikolaus
author_facet Leutritz, Tobias
Seif, Maryam
Helms, Gunther
Samson, Rebecca S
Curt, Armin
Freund, Patrick
Weiskopf, Nikolaus
author_sort Leutritz, Tobias
collection PubMed
description Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole‐brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI‐toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter‐site comparability, the intra‐site (i.e., scan‐rescan experiment) coefficient of variation (CoV), inter‐site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra‐ and inter‐site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra‐site CoV (16%) was observed in R2* maps. The inter‐site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials.
format Online
Article
Text
id pubmed-7502832
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-75028322020-09-28 Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study Leutritz, Tobias Seif, Maryam Helms, Gunther Samson, Rebecca S Curt, Armin Freund, Patrick Weiskopf, Nikolaus Hum Brain Mapp Research Articles Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole‐brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI‐toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter‐site comparability, the intra‐site (i.e., scan‐rescan experiment) coefficient of variation (CoV), inter‐site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra‐ and inter‐site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra‐site CoV (16%) was observed in R2* maps. The inter‐site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials. John Wiley & Sons, Inc. 2020-07-08 /pmc/articles/PMC7502832/ /pubmed/32639104 http://dx.doi.org/10.1002/hbm.25122 Text en © 2020 The Authors. Human Brain Mapping published by Wiley Periodicals LLC. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Leutritz, Tobias
Seif, Maryam
Helms, Gunther
Samson, Rebecca S
Curt, Armin
Freund, Patrick
Weiskopf, Nikolaus
Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title_full Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title_fullStr Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title_full_unstemmed Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title_short Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
title_sort multiparameter mapping of relaxation (r1, r2*), proton density and magnetization transfer saturation at 3 t: a multicenter dual‐vendor reproducibility and repeatability study
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502832/
https://www.ncbi.nlm.nih.gov/pubmed/32639104
http://dx.doi.org/10.1002/hbm.25122
work_keys_str_mv AT leutritztobias multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT seifmaryam multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT helmsgunther multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT samsonrebeccas multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT curtarmin multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT freundpatrick multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy
AT weiskopfnikolaus multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy