Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study
Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502832/ https://www.ncbi.nlm.nih.gov/pubmed/32639104 http://dx.doi.org/10.1002/hbm.25122 |
_version_ | 1783584273015504896 |
---|---|
author | Leutritz, Tobias Seif, Maryam Helms, Gunther Samson, Rebecca S Curt, Armin Freund, Patrick Weiskopf, Nikolaus |
author_facet | Leutritz, Tobias Seif, Maryam Helms, Gunther Samson, Rebecca S Curt, Armin Freund, Patrick Weiskopf, Nikolaus |
author_sort | Leutritz, Tobias |
collection | PubMed |
description | Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole‐brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI‐toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter‐site comparability, the intra‐site (i.e., scan‐rescan experiment) coefficient of variation (CoV), inter‐site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra‐ and inter‐site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra‐site CoV (16%) was observed in R2* maps. The inter‐site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials. |
format | Online Article Text |
id | pubmed-7502832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley & Sons, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75028322020-09-28 Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study Leutritz, Tobias Seif, Maryam Helms, Gunther Samson, Rebecca S Curt, Armin Freund, Patrick Weiskopf, Nikolaus Hum Brain Mapp Research Articles Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole‐brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI‐toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter‐site comparability, the intra‐site (i.e., scan‐rescan experiment) coefficient of variation (CoV), inter‐site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra‐ and inter‐site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra‐site CoV (16%) was observed in R2* maps. The inter‐site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials. John Wiley & Sons, Inc. 2020-07-08 /pmc/articles/PMC7502832/ /pubmed/32639104 http://dx.doi.org/10.1002/hbm.25122 Text en © 2020 The Authors. Human Brain Mapping published by Wiley Periodicals LLC. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Leutritz, Tobias Seif, Maryam Helms, Gunther Samson, Rebecca S Curt, Armin Freund, Patrick Weiskopf, Nikolaus Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title | Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title_full | Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title_fullStr | Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title_full_unstemmed | Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title_short | Multiparameter mapping of relaxation (R1, R2*), proton density and magnetization transfer saturation at 3 T: A multicenter dual‐vendor reproducibility and repeatability study |
title_sort | multiparameter mapping of relaxation (r1, r2*), proton density and magnetization transfer saturation at 3 t: a multicenter dual‐vendor reproducibility and repeatability study |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7502832/ https://www.ncbi.nlm.nih.gov/pubmed/32639104 http://dx.doi.org/10.1002/hbm.25122 |
work_keys_str_mv | AT leutritztobias multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT seifmaryam multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT helmsgunther multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT samsonrebeccas multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT curtarmin multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT freundpatrick multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy AT weiskopfnikolaus multiparametermappingofrelaxationr1r2protondensityandmagnetizationtransfersaturationat3tamulticenterdualvendorreproducibilityandrepeatabilitystudy |