Cargando…
Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation
The severity of aortic stenosis (AS) has traditionally been graded by measuring hemodynamic parameters of transvalvular pressure gradient, ejection jet velocity, or estimating valve orifice area. Recent research has highlighted limitations of these criteria at effectively grading AS in presence of l...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506067/ https://www.ncbi.nlm.nih.gov/pubmed/33013489 http://dx.doi.org/10.3389/fphys.2020.574211 |
_version_ | 1783584950597976064 |
---|---|
author | Wisneski, Andrew D. Wang, Yunjie Deuse, Tobias Hill, Arthur C. Pasta, Salvatore Sack, Kevin L. Yao, Jiang Guccione, Julius M. |
author_facet | Wisneski, Andrew D. Wang, Yunjie Deuse, Tobias Hill, Arthur C. Pasta, Salvatore Sack, Kevin L. Yao, Jiang Guccione, Julius M. |
author_sort | Wisneski, Andrew D. |
collection | PubMed |
description | The severity of aortic stenosis (AS) has traditionally been graded by measuring hemodynamic parameters of transvalvular pressure gradient, ejection jet velocity, or estimating valve orifice area. Recent research has highlighted limitations of these criteria at effectively grading AS in presence of left ventricle (LV) dysfunction. We hypothesized that simulations coupling the aorta and LV could provide meaningful insight into myocardial biomechanical derangements that accompany AS. A realistic finite element model of the human heart with a coupled lumped-parameter circulatory system was used to simulate AS. Finite element analysis was performed with Abaqus FEA. An anisotropic hyperelastic model was assigned to LV passive properties, and a time-varying elastance function governed the LV active response. Global LV myofiber peak systolic stress (mean ± standard deviation) was 9.31 ± 10.33 kPa at baseline, 13.13 ± 10.29 kPa for moderate AS, and 16.18 ± 10.59 kPa for severe AS. Mean LV myofiber peak systolic strains were −22.40 ± 8.73%, −22.24 ± 8.91%, and −21.97 ± 9.18%, respectively. Stress was significantly elevated compared to baseline for moderate (p < 0.01) and severe AS (p < 0.001), and when compared to each other (p < 0.01). Ventricular regions that experienced the greatest systolic stress were (severe AS vs. baseline) basal inferior (39.87 vs. 30.02 kPa; p < 0.01), mid-anteroseptal (32.29 vs. 24.79 kPa; p < 0.001), and apex (27.99 vs. 23.52 kPa; p < 0.001). This data serves as a reference for future studies that will incorporate patient-specific ventricular geometries and material parameters, aiming to correlate LV biomechanics to AS severity. |
format | Online Article Text |
id | pubmed-7506067 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75060672020-10-02 Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation Wisneski, Andrew D. Wang, Yunjie Deuse, Tobias Hill, Arthur C. Pasta, Salvatore Sack, Kevin L. Yao, Jiang Guccione, Julius M. Front Physiol Physiology The severity of aortic stenosis (AS) has traditionally been graded by measuring hemodynamic parameters of transvalvular pressure gradient, ejection jet velocity, or estimating valve orifice area. Recent research has highlighted limitations of these criteria at effectively grading AS in presence of left ventricle (LV) dysfunction. We hypothesized that simulations coupling the aorta and LV could provide meaningful insight into myocardial biomechanical derangements that accompany AS. A realistic finite element model of the human heart with a coupled lumped-parameter circulatory system was used to simulate AS. Finite element analysis was performed with Abaqus FEA. An anisotropic hyperelastic model was assigned to LV passive properties, and a time-varying elastance function governed the LV active response. Global LV myofiber peak systolic stress (mean ± standard deviation) was 9.31 ± 10.33 kPa at baseline, 13.13 ± 10.29 kPa for moderate AS, and 16.18 ± 10.59 kPa for severe AS. Mean LV myofiber peak systolic strains were −22.40 ± 8.73%, −22.24 ± 8.91%, and −21.97 ± 9.18%, respectively. Stress was significantly elevated compared to baseline for moderate (p < 0.01) and severe AS (p < 0.001), and when compared to each other (p < 0.01). Ventricular regions that experienced the greatest systolic stress were (severe AS vs. baseline) basal inferior (39.87 vs. 30.02 kPa; p < 0.01), mid-anteroseptal (32.29 vs. 24.79 kPa; p < 0.001), and apex (27.99 vs. 23.52 kPa; p < 0.001). This data serves as a reference for future studies that will incorporate patient-specific ventricular geometries and material parameters, aiming to correlate LV biomechanics to AS severity. Frontiers Media S.A. 2020-09-08 /pmc/articles/PMC7506067/ /pubmed/33013489 http://dx.doi.org/10.3389/fphys.2020.574211 Text en Copyright © 2020 Wisneski, Wang, Deuse, Hill, Pasta, Sack, Yao and Guccione. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Wisneski, Andrew D. Wang, Yunjie Deuse, Tobias Hill, Arthur C. Pasta, Salvatore Sack, Kevin L. Yao, Jiang Guccione, Julius M. Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title | Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title_full | Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title_fullStr | Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title_full_unstemmed | Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title_short | Impact of Aortic Stenosis on Myofiber Stress: Translational Application of Left Ventricle-Aortic Coupling Simulation |
title_sort | impact of aortic stenosis on myofiber stress: translational application of left ventricle-aortic coupling simulation |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506067/ https://www.ncbi.nlm.nih.gov/pubmed/33013489 http://dx.doi.org/10.3389/fphys.2020.574211 |
work_keys_str_mv | AT wisneskiandrewd impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT wangyunjie impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT deusetobias impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT hillarthurc impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT pastasalvatore impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT sackkevinl impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT yaojiang impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation AT guccionejuliusm impactofaorticstenosisonmyofiberstresstranslationalapplicationofleftventricleaorticcouplingsimulation |