Cargando…

Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †

Waveguides with sub-100 nm thickness offer a promising platform for sensors. We designed and analyzed multimode interference (MMI) devices using these ultrathin platforms for use as biosensors. To verify our design methodology, we compared the measured and simulated spectra of fabricated 220-nm-thic...

Descripción completa

Detalles Bibliográficos
Autores principales: Y. Elsayed, Mohamed, M. Sherif, Sherif, S. Aljaber, Amina, A. Swillam, Mohamed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506679/
https://www.ncbi.nlm.nih.gov/pubmed/32883015
http://dx.doi.org/10.3390/s20174955
_version_ 1783585069211844608
author Y. Elsayed, Mohamed
M. Sherif, Sherif
S. Aljaber, Amina
A. Swillam, Mohamed
author_facet Y. Elsayed, Mohamed
M. Sherif, Sherif
S. Aljaber, Amina
A. Swillam, Mohamed
author_sort Y. Elsayed, Mohamed
collection PubMed
description Waveguides with sub-100 nm thickness offer a promising platform for sensors. We designed and analyzed multimode interference (MMI) devices using these ultrathin platforms for use as biosensors. To verify our design methodology, we compared the measured and simulated spectra of fabricated 220-nm-thick MMI devices. Designs of the MMI biosensors based on the sub-100 nm platforms have been optimized using finite difference time domain simulations. At a length of 4 mm, the 50-nm-thick MMI sensor provides a sensitivity of roughly 420 nm/RIU and with a figure of merit (FOM) definition of sensitivity/full-width-at-half-maximum, the FOM is 133. On the other hand, using a thickness of 70 nm results in a more compact design—only 2.4 mm length was required to achieve a similar FOM, 134, with a sensitivity of 330 nm/RIU. The limits of detection (LOD) were calculated to be 7.1 × 10(−6) RIU and 8.6 × 10(−6) RIU for the 50 nm and the 70-nm-thick sensor, respectively. The LOD for glucose sensing was calculated to be less than 10 mg dL(−1) making it useful for detecting glucose in the diabetic range. The biosensor is also predicted to be able to detect layers of protein, such as biotin-streptavidin as thin as 1 nm. The ultrathin SOI waveguide platform is promising in biosensing applications using this simple MMI structure.
format Online
Article
Text
id pubmed-7506679
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75066792020-09-26 Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device † Y. Elsayed, Mohamed M. Sherif, Sherif S. Aljaber, Amina A. Swillam, Mohamed Sensors (Basel) Letter Waveguides with sub-100 nm thickness offer a promising platform for sensors. We designed and analyzed multimode interference (MMI) devices using these ultrathin platforms for use as biosensors. To verify our design methodology, we compared the measured and simulated spectra of fabricated 220-nm-thick MMI devices. Designs of the MMI biosensors based on the sub-100 nm platforms have been optimized using finite difference time domain simulations. At a length of 4 mm, the 50-nm-thick MMI sensor provides a sensitivity of roughly 420 nm/RIU and with a figure of merit (FOM) definition of sensitivity/full-width-at-half-maximum, the FOM is 133. On the other hand, using a thickness of 70 nm results in a more compact design—only 2.4 mm length was required to achieve a similar FOM, 134, with a sensitivity of 330 nm/RIU. The limits of detection (LOD) were calculated to be 7.1 × 10(−6) RIU and 8.6 × 10(−6) RIU for the 50 nm and the 70-nm-thick sensor, respectively. The LOD for glucose sensing was calculated to be less than 10 mg dL(−1) making it useful for detecting glucose in the diabetic range. The biosensor is also predicted to be able to detect layers of protein, such as biotin-streptavidin as thin as 1 nm. The ultrathin SOI waveguide platform is promising in biosensing applications using this simple MMI structure. MDPI 2020-09-01 /pmc/articles/PMC7506679/ /pubmed/32883015 http://dx.doi.org/10.3390/s20174955 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Letter
Y. Elsayed, Mohamed
M. Sherif, Sherif
S. Aljaber, Amina
A. Swillam, Mohamed
Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title_full Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title_fullStr Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title_full_unstemmed Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title_short Integrated Lab-on-a-Chip Optical Biosensor Using Ultrathin Silicon Waveguide SOI MMI Device †
title_sort integrated lab-on-a-chip optical biosensor using ultrathin silicon waveguide soi mmi device †
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506679/
https://www.ncbi.nlm.nih.gov/pubmed/32883015
http://dx.doi.org/10.3390/s20174955
work_keys_str_mv AT yelsayedmohamed integratedlabonachipopticalbiosensorusingultrathinsiliconwaveguidesoimmidevice
AT msherifsherif integratedlabonachipopticalbiosensorusingultrathinsiliconwaveguidesoimmidevice
AT saljaberamina integratedlabonachipopticalbiosensorusingultrathinsiliconwaveguidesoimmidevice
AT aswillammohamed integratedlabonachipopticalbiosensorusingultrathinsiliconwaveguidesoimmidevice