Cargando…
Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach
This article presents a mechanical fault diagnosis methodology in synchronous machines using only a single current measurement in variable speed conditions. The proposed methodology uses order tracking in order to sample the analysis signal as a function of the rotor angle. The spectrum of the signa...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506800/ https://www.ncbi.nlm.nih.gov/pubmed/32899369 http://dx.doi.org/10.3390/s20175011 |
_version_ | 1783585097073557504 |
---|---|
author | Allouche, Abdallah Etien, Erik Rambault, Laurent Doget, Thierry Cauet, Sebastien Sakout, Anas |
author_facet | Allouche, Abdallah Etien, Erik Rambault, Laurent Doget, Thierry Cauet, Sebastien Sakout, Anas |
author_sort | Allouche, Abdallah |
collection | PubMed |
description | This article presents a mechanical fault diagnosis methodology in synchronous machines using only a single current measurement in variable speed conditions. The proposed methodology uses order tracking in order to sample the analysis signal as a function of the rotor angle. The spectrum of the signal is then independent of speed and it could be employed in frequency analysis. Order tracking is usually applied using rotor position measurement. In this work, the proposed method uses one current measurement to estimate the position as well as the analysis signal (rotation speed). Furthermore, a statistical approach is used to create a complete diagnosis protocol. At variable speed and with only one current measurement the diagnosis is challenging. However, order tracking will allow simpler analysis. The method is proved in simulations and experimental set-up. |
format | Online Article Text |
id | pubmed-7506800 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75068002020-09-26 Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach Allouche, Abdallah Etien, Erik Rambault, Laurent Doget, Thierry Cauet, Sebastien Sakout, Anas Sensors (Basel) Letter This article presents a mechanical fault diagnosis methodology in synchronous machines using only a single current measurement in variable speed conditions. The proposed methodology uses order tracking in order to sample the analysis signal as a function of the rotor angle. The spectrum of the signal is then independent of speed and it could be employed in frequency analysis. Order tracking is usually applied using rotor position measurement. In this work, the proposed method uses one current measurement to estimate the position as well as the analysis signal (rotation speed). Furthermore, a statistical approach is used to create a complete diagnosis protocol. At variable speed and with only one current measurement the diagnosis is challenging. However, order tracking will allow simpler analysis. The method is proved in simulations and experimental set-up. MDPI 2020-09-03 /pmc/articles/PMC7506800/ /pubmed/32899369 http://dx.doi.org/10.3390/s20175011 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Allouche, Abdallah Etien, Erik Rambault, Laurent Doget, Thierry Cauet, Sebastien Sakout, Anas Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title | Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title_full | Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title_fullStr | Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title_full_unstemmed | Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title_short | Mechanical Fault Diagnostic in PMSM from Only One Current Measurement: A Tacholess Order Tracking Approach |
title_sort | mechanical fault diagnostic in pmsm from only one current measurement: a tacholess order tracking approach |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506800/ https://www.ncbi.nlm.nih.gov/pubmed/32899369 http://dx.doi.org/10.3390/s20175011 |
work_keys_str_mv | AT alloucheabdallah mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach AT etienerik mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach AT rambaultlaurent mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach AT dogetthierry mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach AT cauetsebastien mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach AT sakoutanas mechanicalfaultdiagnosticinpmsmfromonlyonecurrentmeasurementatacholessordertrackingapproach |