Cargando…
Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline
Since the observation precision of the Global Navigation Satellite System (GNSS) carrier phase is on the order of millimeters, if the phase ambiguity is correctly solved, while calibrating the receiver inter-frequency bias, time synchronization on the order of tens of picoseconds is expected. In thi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506859/ https://www.ncbi.nlm.nih.gov/pubmed/32872294 http://dx.doi.org/10.3390/s20174882 |
_version_ | 1783585109525397504 |
---|---|
author | Zhao, Yinghao Zhou, Letao Feng, Wei Xu, Shaoguang |
author_facet | Zhao, Yinghao Zhou, Letao Feng, Wei Xu, Shaoguang |
author_sort | Zhao, Yinghao |
collection | PubMed |
description | Since the observation precision of the Global Navigation Satellite System (GNSS) carrier phase is on the order of millimeters, if the phase ambiguity is correctly solved, while calibrating the receiver inter-frequency bias, time synchronization on the order of tens of picoseconds is expected. In this contribution, a method that considers the prior constraints of the between-receiver inter-frequency bias (IFB) and its random variation characteristics is proposed for the estimation of the between-receiver clock difference, based on the uncombined GNSS carrier phase and pseudorange observations of the zero and short baselines. The proposed method can rapidly achieve the single-difference ambiguity resolution of the zero and short baselines, and then obtain the high-precision relative clock offset, by using only the carrier phase observations, along with the between-receiver IFBs being simultaneously determined. Our numerical tests, carried out using GNSS observations sampled every 30 s by a dedicatedly selected set of zero and short baselines, show that the method can fix the between-receiver single-difference ambiguity successfully within an average of fewer than 2 epochs (interval 30 s). Then, a clock difference between two receivers with millimeter precision is obtained, achieving time synchronization on tens of picoseconds level, and deriving a frequency stability of 5 × 10(−14) for averaging times of 30,000 s. Furthermore, the proposed approach is compared with the precise point positioning (PPP) time transfer method. The results show that, for different types of receivers, the agreement between the two methods is between −6.7 ns and 0.2 ns. |
format | Online Article Text |
id | pubmed-7506859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75068592020-09-26 Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline Zhao, Yinghao Zhou, Letao Feng, Wei Xu, Shaoguang Sensors (Basel) Article Since the observation precision of the Global Navigation Satellite System (GNSS) carrier phase is on the order of millimeters, if the phase ambiguity is correctly solved, while calibrating the receiver inter-frequency bias, time synchronization on the order of tens of picoseconds is expected. In this contribution, a method that considers the prior constraints of the between-receiver inter-frequency bias (IFB) and its random variation characteristics is proposed for the estimation of the between-receiver clock difference, based on the uncombined GNSS carrier phase and pseudorange observations of the zero and short baselines. The proposed method can rapidly achieve the single-difference ambiguity resolution of the zero and short baselines, and then obtain the high-precision relative clock offset, by using only the carrier phase observations, along with the between-receiver IFBs being simultaneously determined. Our numerical tests, carried out using GNSS observations sampled every 30 s by a dedicatedly selected set of zero and short baselines, show that the method can fix the between-receiver single-difference ambiguity successfully within an average of fewer than 2 epochs (interval 30 s). Then, a clock difference between two receivers with millimeter precision is obtained, achieving time synchronization on tens of picoseconds level, and deriving a frequency stability of 5 × 10(−14) for averaging times of 30,000 s. Furthermore, the proposed approach is compared with the precise point positioning (PPP) time transfer method. The results show that, for different types of receivers, the agreement between the two methods is between −6.7 ns and 0.2 ns. MDPI 2020-08-28 /pmc/articles/PMC7506859/ /pubmed/32872294 http://dx.doi.org/10.3390/s20174882 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Yinghao Zhou, Letao Feng, Wei Xu, Shaoguang Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title | Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title_full | Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title_fullStr | Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title_full_unstemmed | Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title_short | Fast Time Synchronization on Tens of Picoseconds Level Using Uncombined GNSS Carrier Phase of Zero/Short Baseline |
title_sort | fast time synchronization on tens of picoseconds level using uncombined gnss carrier phase of zero/short baseline |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506859/ https://www.ncbi.nlm.nih.gov/pubmed/32872294 http://dx.doi.org/10.3390/s20174882 |
work_keys_str_mv | AT zhaoyinghao fasttimesynchronizationontensofpicosecondslevelusinguncombinedgnsscarrierphaseofzeroshortbaseline AT zhouletao fasttimesynchronizationontensofpicosecondslevelusinguncombinedgnsscarrierphaseofzeroshortbaseline AT fengwei fasttimesynchronizationontensofpicosecondslevelusinguncombinedgnsscarrierphaseofzeroshortbaseline AT xushaoguang fasttimesynchronizationontensofpicosecondslevelusinguncombinedgnsscarrierphaseofzeroshortbaseline |