On the Use of a Rotatable ECT Sensor to Investigate Dense Phase Flow: A Feasibility Study

This paper presents the feasibility study of dynamic flow measurements using the concept of a rotatable electrical capacitance tomography (ECT) sensor. The experiment considered horizontal flow in a pneumatic conveying flow loop in the case of dense phase flow. Slugs and settled layers were imaged a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wajman, Radosław, Banasiak, Robert, Babout, Laurent
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506880/
https://www.ncbi.nlm.nih.gov/pubmed/32867266
http://dx.doi.org/10.3390/s20174854
Descripción
Sumario:This paper presents the feasibility study of dynamic flow measurements using the concept of a rotatable electrical capacitance tomography (ECT) sensor. The experiment considered horizontal flow in a pneumatic conveying flow loop in the case of dense phase flow. Slugs and settled layers were imaged and a comparison was made between no rotation or rotation of the sensor for two image reconstruction schemas: linear back projection (LBP) and non-linear iterative back projection. Data were evaluated both qualitatively and quantitatively by estimating the solids concentration level for different hue levels.