Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a nee...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506937/ https://www.ncbi.nlm.nih.gov/pubmed/32858989 http://dx.doi.org/10.3390/s20174820 |
_version_ | 1783585127432978432 |
---|---|
author | Kaczmarek, Wojciech Panasiuk, Jarosław Borys, Szymon Pobudkowska, Aneta Majsterek, Mikołaj |
author_facet | Kaczmarek, Wojciech Panasiuk, Jarosław Borys, Szymon Pobudkowska, Aneta Majsterek, Mikołaj |
author_sort | Kaczmarek, Wojciech |
collection | PubMed |
description | The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a need to develop a system that can predict the formation of chlorine water disinfection by-products, such as trihalomethanes (THMs). THMs are volatile organic compounds from the group of alkyl halides, carcinogenic, mutagenic, teratogenic, and bioaccumulating. Long-term exposure, even to low concentrations of THM in water and air, may result in damage to the liver, kidneys, thyroid gland, or nervous system. This article focuses on analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale. The designed and constructed analytical device is based on the SIMATIC S7-1200 PLC driver of SIEMENS Company. The HMI KPT panel of SIEMENS Company enables monitoring the process and control individual elements of device. Value of the reaction rate constant of free chlorine decomposition gives us qualitative information about water quality, it is also strictly connected to the kinetics of the reaction. Based on the experiment results, the value of reaction rate constant was determined as a linear change of the natural logarithm of free chlorine concentration over time. The experimental value of activation energy based on the directional coefficient is equal to 76.0 [Formula: see text]. These results indicate that changing water temperature does not cause any changes in the reaction rate, while it still affects the value of the reaction rate constant. Using the analytical device, it is possible to constantly monitor the values of reaction rate constant and activation energy, which can be used to develop a new way to assess pool water quality. |
format | Online Article Text |
id | pubmed-7506937 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75069372020-09-30 Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale Kaczmarek, Wojciech Panasiuk, Jarosław Borys, Szymon Pobudkowska, Aneta Majsterek, Mikołaj Sensors (Basel) Article The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a need to develop a system that can predict the formation of chlorine water disinfection by-products, such as trihalomethanes (THMs). THMs are volatile organic compounds from the group of alkyl halides, carcinogenic, mutagenic, teratogenic, and bioaccumulating. Long-term exposure, even to low concentrations of THM in water and air, may result in damage to the liver, kidneys, thyroid gland, or nervous system. This article focuses on analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale. The designed and constructed analytical device is based on the SIMATIC S7-1200 PLC driver of SIEMENS Company. The HMI KPT panel of SIEMENS Company enables monitoring the process and control individual elements of device. Value of the reaction rate constant of free chlorine decomposition gives us qualitative information about water quality, it is also strictly connected to the kinetics of the reaction. Based on the experiment results, the value of reaction rate constant was determined as a linear change of the natural logarithm of free chlorine concentration over time. The experimental value of activation energy based on the directional coefficient is equal to 76.0 [Formula: see text]. These results indicate that changing water temperature does not cause any changes in the reaction rate, while it still affects the value of the reaction rate constant. Using the analytical device, it is possible to constantly monitor the values of reaction rate constant and activation energy, which can be used to develop a new way to assess pool water quality. MDPI 2020-08-26 /pmc/articles/PMC7506937/ /pubmed/32858989 http://dx.doi.org/10.3390/s20174820 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kaczmarek, Wojciech Panasiuk, Jarosław Borys, Szymon Pobudkowska, Aneta Majsterek, Mikołaj Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title | Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title_full | Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title_fullStr | Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title_full_unstemmed | Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title_short | Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale |
title_sort | analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506937/ https://www.ncbi.nlm.nih.gov/pubmed/32858989 http://dx.doi.org/10.3390/s20174820 |
work_keys_str_mv | AT kaczmarekwojciech analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale AT panasiukjarosław analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale AT borysszymon analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale AT pobudkowskaaneta analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale AT majsterekmikołaj analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale |