Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale

The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a nee...

Descripción completa

Detalles Bibliográficos
Autores principales: Kaczmarek, Wojciech, Panasiuk, Jarosław, Borys, Szymon, Pobudkowska, Aneta, Majsterek, Mikołaj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506937/
https://www.ncbi.nlm.nih.gov/pubmed/32858989
http://dx.doi.org/10.3390/s20174820
_version_ 1783585127432978432
author Kaczmarek, Wojciech
Panasiuk, Jarosław
Borys, Szymon
Pobudkowska, Aneta
Majsterek, Mikołaj
author_facet Kaczmarek, Wojciech
Panasiuk, Jarosław
Borys, Szymon
Pobudkowska, Aneta
Majsterek, Mikołaj
author_sort Kaczmarek, Wojciech
collection PubMed
description The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a need to develop a system that can predict the formation of chlorine water disinfection by-products, such as trihalomethanes (THMs). THMs are volatile organic compounds from the group of alkyl halides, carcinogenic, mutagenic, teratogenic, and bioaccumulating. Long-term exposure, even to low concentrations of THM in water and air, may result in damage to the liver, kidneys, thyroid gland, or nervous system. This article focuses on analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale. The designed and constructed analytical device is based on the SIMATIC S7-1200 PLC driver of SIEMENS Company. The HMI KPT panel of SIEMENS Company enables monitoring the process and control individual elements of device. Value of the reaction rate constant of free chlorine decomposition gives us qualitative information about water quality, it is also strictly connected to the kinetics of the reaction. Based on the experiment results, the value of reaction rate constant was determined as a linear change of the natural logarithm of free chlorine concentration over time. The experimental value of activation energy based on the directional coefficient is equal to 76.0 [Formula: see text]. These results indicate that changing water temperature does not cause any changes in the reaction rate, while it still affects the value of the reaction rate constant. Using the analytical device, it is possible to constantly monitor the values of reaction rate constant and activation energy, which can be used to develop a new way to assess pool water quality.
format Online
Article
Text
id pubmed-7506937
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75069372020-09-30 Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale Kaczmarek, Wojciech Panasiuk, Jarosław Borys, Szymon Pobudkowska, Aneta Majsterek, Mikołaj Sensors (Basel) Article The most common cause of diseases in swimming pools is the lack of sanitary control of water quality; water may contain microbiological and chemical contaminants. Among the people most at risk of infection are children, pregnant women, and immunocompromised people. The origin of the problem is a need to develop a system that can predict the formation of chlorine water disinfection by-products, such as trihalomethanes (THMs). THMs are volatile organic compounds from the group of alkyl halides, carcinogenic, mutagenic, teratogenic, and bioaccumulating. Long-term exposure, even to low concentrations of THM in water and air, may result in damage to the liver, kidneys, thyroid gland, or nervous system. This article focuses on analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale. The designed and constructed analytical device is based on the SIMATIC S7-1200 PLC driver of SIEMENS Company. The HMI KPT panel of SIEMENS Company enables monitoring the process and control individual elements of device. Value of the reaction rate constant of free chlorine decomposition gives us qualitative information about water quality, it is also strictly connected to the kinetics of the reaction. Based on the experiment results, the value of reaction rate constant was determined as a linear change of the natural logarithm of free chlorine concentration over time. The experimental value of activation energy based on the directional coefficient is equal to 76.0 [Formula: see text]. These results indicate that changing water temperature does not cause any changes in the reaction rate, while it still affects the value of the reaction rate constant. Using the analytical device, it is possible to constantly monitor the values of reaction rate constant and activation energy, which can be used to develop a new way to assess pool water quality. MDPI 2020-08-26 /pmc/articles/PMC7506937/ /pubmed/32858989 http://dx.doi.org/10.3390/s20174820 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kaczmarek, Wojciech
Panasiuk, Jarosław
Borys, Szymon
Pobudkowska, Aneta
Majsterek, Mikołaj
Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title_full Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title_fullStr Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title_full_unstemmed Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title_short Analysis of the Kinetics of Swimming Pool Water Reaction in Analytical Device Reproducing Its Circulation on a Small Scale
title_sort analysis of the kinetics of swimming pool water reaction in analytical device reproducing its circulation on a small scale
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7506937/
https://www.ncbi.nlm.nih.gov/pubmed/32858989
http://dx.doi.org/10.3390/s20174820
work_keys_str_mv AT kaczmarekwojciech analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale
AT panasiukjarosław analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale
AT borysszymon analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale
AT pobudkowskaaneta analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale
AT majsterekmikołaj analysisofthekineticsofswimmingpoolwaterreactioninanalyticaldevicereproducingitscirculationonasmallscale