Cargando…
Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study
BACKGROUND: Cardiovascular implantable electronic devices (CIEDs) with physical activity (PA) recording function can continuously and automatically collect patients’ long-term PA data. The dose-response association of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7507242/ https://www.ncbi.nlm.nih.gov/pubmed/32957993 http://dx.doi.org/10.1186/s12966-020-01026-2 |
_version_ | 1783585188831297536 |
---|---|
author | Li, Xiaoyao Zhao, Shuang Chen, Keping Hua, Wei Su, Yangang Yang, Jiefu Liang, Zhaoguang Xu, Wei Zhang, Shu |
author_facet | Li, Xiaoyao Zhao, Shuang Chen, Keping Hua, Wei Su, Yangang Yang, Jiefu Liang, Zhaoguang Xu, Wei Zhang, Shu |
author_sort | Li, Xiaoyao |
collection | PubMed |
description | BACKGROUND: Cardiovascular implantable electronic devices (CIEDs) with physical activity (PA) recording function can continuously and automatically collect patients’ long-term PA data. The dose-response association of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRTD)-measured PA with cardiovascular outcomes in patients at high risk of sudden cardiac death (SCD) was investigated. METHODS: In total, 822 patients fulfilling the inclusion criteria were included and divided into three groups according to baseline PA tertiles: tertile 1 (< 8.04%, n = 274), tertile 2 (8.04–13.24%, n = 274), and tertile 3 (> 13.24%, n = 274). The primary endpoint was cardiac death, the secondary endpoint was all-cause mortality. RESULTS: During a mean follow-up of 59.7 ± 22.4 months, cardiac death (18.6% vs 8.8% vs 5.5%, tertiles 1–3, P < 0.001) and all-cause mortality (39.4% vs 20.4% vs 9.9%, tertiles 1–3, P < 0.001) events decreased according to PA tertiles. Compared with patients younger than 60 years old, older patients had a lower average PA level (9.6% vs 12.8%, P < 0.001) but higher rates of cardiac death (13.2% vs 8.1%, P = 0.024) and all-cause mortality (28.4% vs 16.7%, P < 0.001) events. Adjusted multivariate Cox regression analyses showed that a higher tertile of PA was associated with a lower risk of cardiac death (hazard ratio (HR) 0.41, 95% confidence interval (CI): 0.25–0.68, tertile 2 vs tertile 1; HR 0.28, 95% CI: 0.15–0.51, tertile 3 vs tertile 1, P (trend) < 0.001). Similar results were observed for all-cause mortality. The dose-response curve showed an inverse non-linear pattern, and a significant reduction in endpoint risk was observed at the low-moderate PA level. The HR for cardiac death was reduced by half with 12.32% PA (177 min), and the HR for all-cause mortality was reduced by half with 11.92% PA (172 min). Subgroup analysis results indicated that older adults could benefit from PA and the range for achieving optimal benefits might be lower. CONCLUSIONS: PA monitoring may aid in long-term management of patients at high risk of SCD. More PA will generate better survival benefits, but even low-moderate PA is already good especially for older adults, which is relatively easy to achieve. |
format | Online Article Text |
id | pubmed-7507242 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-75072422020-09-23 Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study Li, Xiaoyao Zhao, Shuang Chen, Keping Hua, Wei Su, Yangang Yang, Jiefu Liang, Zhaoguang Xu, Wei Zhang, Shu Int J Behav Nutr Phys Act Research BACKGROUND: Cardiovascular implantable electronic devices (CIEDs) with physical activity (PA) recording function can continuously and automatically collect patients’ long-term PA data. The dose-response association of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRTD)-measured PA with cardiovascular outcomes in patients at high risk of sudden cardiac death (SCD) was investigated. METHODS: In total, 822 patients fulfilling the inclusion criteria were included and divided into three groups according to baseline PA tertiles: tertile 1 (< 8.04%, n = 274), tertile 2 (8.04–13.24%, n = 274), and tertile 3 (> 13.24%, n = 274). The primary endpoint was cardiac death, the secondary endpoint was all-cause mortality. RESULTS: During a mean follow-up of 59.7 ± 22.4 months, cardiac death (18.6% vs 8.8% vs 5.5%, tertiles 1–3, P < 0.001) and all-cause mortality (39.4% vs 20.4% vs 9.9%, tertiles 1–3, P < 0.001) events decreased according to PA tertiles. Compared with patients younger than 60 years old, older patients had a lower average PA level (9.6% vs 12.8%, P < 0.001) but higher rates of cardiac death (13.2% vs 8.1%, P = 0.024) and all-cause mortality (28.4% vs 16.7%, P < 0.001) events. Adjusted multivariate Cox regression analyses showed that a higher tertile of PA was associated with a lower risk of cardiac death (hazard ratio (HR) 0.41, 95% confidence interval (CI): 0.25–0.68, tertile 2 vs tertile 1; HR 0.28, 95% CI: 0.15–0.51, tertile 3 vs tertile 1, P (trend) < 0.001). Similar results were observed for all-cause mortality. The dose-response curve showed an inverse non-linear pattern, and a significant reduction in endpoint risk was observed at the low-moderate PA level. The HR for cardiac death was reduced by half with 12.32% PA (177 min), and the HR for all-cause mortality was reduced by half with 11.92% PA (172 min). Subgroup analysis results indicated that older adults could benefit from PA and the range for achieving optimal benefits might be lower. CONCLUSIONS: PA monitoring may aid in long-term management of patients at high risk of SCD. More PA will generate better survival benefits, but even low-moderate PA is already good especially for older adults, which is relatively easy to achieve. BioMed Central 2020-09-21 /pmc/articles/PMC7507242/ /pubmed/32957993 http://dx.doi.org/10.1186/s12966-020-01026-2 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Li, Xiaoyao Zhao, Shuang Chen, Keping Hua, Wei Su, Yangang Yang, Jiefu Liang, Zhaoguang Xu, Wei Zhang, Shu Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title | Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title_full | Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title_fullStr | Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title_full_unstemmed | Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title_short | Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
title_sort | dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7507242/ https://www.ncbi.nlm.nih.gov/pubmed/32957993 http://dx.doi.org/10.1186/s12966-020-01026-2 |
work_keys_str_mv | AT lixiaoyao doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT zhaoshuang doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT chenkeping doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT huawei doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT suyangang doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT yangjiefu doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT liangzhaoguang doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT xuwei doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy AT zhangshu doseresponseassociationofimplantabledevicemeasuredphysicalactivitywithlongtermcardiacdeathandallcausemortalityinpatientsathighriskofsuddencardiacdeathacohortstudy |