Cargando…

Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates

BACKGROUND: Anterior column-posterior hemitransverse fractures are prevalent in the elderly and are often associated with quadrilateral surface (QLS) comminution. Several special QLS buttress plates have been introduced, but evidence of their comparability with traditional fixation devices is lackin...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Kaifang, Yang, Fan, Yao, Sheng, Xiong, Zekang, Sun, Tingfang, Guo, Xiaodong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Bone and Joint Surgery, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7508287/
https://www.ncbi.nlm.nih.gov/pubmed/32675678
http://dx.doi.org/10.2106/JBJS.19.01027
_version_ 1783585396416839680
author Chen, Kaifang
Yang, Fan
Yao, Sheng
Xiong, Zekang
Sun, Tingfang
Guo, Xiaodong
author_facet Chen, Kaifang
Yang, Fan
Yao, Sheng
Xiong, Zekang
Sun, Tingfang
Guo, Xiaodong
author_sort Chen, Kaifang
collection PubMed
description BACKGROUND: Anterior column-posterior hemitransverse fractures are prevalent in the elderly and are often associated with quadrilateral surface (QLS) comminution. Several special QLS buttress plates have been introduced, but evidence of their comparability with traditional fixation devices is lacking. This biomechanical study aimed to compare special QLS buttress plates with traditional fixation devices. METHODS: Anterior column-posterior hemitransverse fractures with an isolated QLS fragment were created on 24 composite hemipelves and were allocated to 4 fixation groups: (1) infrapectineal QLS buttress plate, (2) suprapectineal QLS buttress plate, (3) suprapectineal reconstruction plate with 3 periarticular long screws, and (4) infrapectineal reconstruction plate with 3 periarticular long screws. Specimens were loaded to simulate partial weight-bearing (35 to 350 N) or full weight-bearing (75 to 750 N). A testing machine was synchronized with a 3-dimensional video tracking system to optically track displacement at the points of interest and to calculate construct stiffness. The fixation systems were compared using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: The experimental results of the partial and full weight-bearing simulations were surprisingly similar. During 40 loading cycles, the maximum displacement on the 6 predetermined points did not exceed 1.1 mm. Multiple-group comparisons of relative displacements of each predetermined measurement point did not differ significantly (p > 0.05). The suprapectineal reconstruction plate with 3 periarticular long screws demonstrated the greatest construct stiffness and significantly greater stiffness than the infrapectineal plate with long screws (p < 0.017). However, no significant difference (p > 0.017) in stiffness was identified between the infrapectineal QLS buttress plate and the suprapectineal reconstruction plate with long screws. CONCLUSIONS: The suprapectineal pelvic brim plate with 3 periarticular long screws remains the gold standard to treat anterior column-posterior hemitransverse fractures. The special infrapectineal QLS buttress plate provides stiffness and stability comparable with those of standard fixation. However, moving the pelvic brim plate from the suprapectineal border to the infrapectineal border is not recommended for anterior column-posterior hemitransverse fractures because it significantly decreases fixation stiffness. CLINICAL RELEVANCE: Special QLS buttress plates may be an alternative fixation method for anterior column-posterior hemitransverse acetabular fractures in the elderly, especially when a less invasive anterior intrapelvic approach is selected.
format Online
Article
Text
id pubmed-7508287
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Journal of Bone and Joint Surgery, Inc.
record_format MEDLINE/PubMed
spelling pubmed-75082872020-09-24 Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates Chen, Kaifang Yang, Fan Yao, Sheng Xiong, Zekang Sun, Tingfang Guo, Xiaodong J Bone Joint Surg Am Scientific Articles BACKGROUND: Anterior column-posterior hemitransverse fractures are prevalent in the elderly and are often associated with quadrilateral surface (QLS) comminution. Several special QLS buttress plates have been introduced, but evidence of their comparability with traditional fixation devices is lacking. This biomechanical study aimed to compare special QLS buttress plates with traditional fixation devices. METHODS: Anterior column-posterior hemitransverse fractures with an isolated QLS fragment were created on 24 composite hemipelves and were allocated to 4 fixation groups: (1) infrapectineal QLS buttress plate, (2) suprapectineal QLS buttress plate, (3) suprapectineal reconstruction plate with 3 periarticular long screws, and (4) infrapectineal reconstruction plate with 3 periarticular long screws. Specimens were loaded to simulate partial weight-bearing (35 to 350 N) or full weight-bearing (75 to 750 N). A testing machine was synchronized with a 3-dimensional video tracking system to optically track displacement at the points of interest and to calculate construct stiffness. The fixation systems were compared using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: The experimental results of the partial and full weight-bearing simulations were surprisingly similar. During 40 loading cycles, the maximum displacement on the 6 predetermined points did not exceed 1.1 mm. Multiple-group comparisons of relative displacements of each predetermined measurement point did not differ significantly (p > 0.05). The suprapectineal reconstruction plate with 3 periarticular long screws demonstrated the greatest construct stiffness and significantly greater stiffness than the infrapectineal plate with long screws (p < 0.017). However, no significant difference (p > 0.017) in stiffness was identified between the infrapectineal QLS buttress plate and the suprapectineal reconstruction plate with long screws. CONCLUSIONS: The suprapectineal pelvic brim plate with 3 periarticular long screws remains the gold standard to treat anterior column-posterior hemitransverse fractures. The special infrapectineal QLS buttress plate provides stiffness and stability comparable with those of standard fixation. However, moving the pelvic brim plate from the suprapectineal border to the infrapectineal border is not recommended for anterior column-posterior hemitransverse fractures because it significantly decreases fixation stiffness. CLINICAL RELEVANCE: Special QLS buttress plates may be an alternative fixation method for anterior column-posterior hemitransverse acetabular fractures in the elderly, especially when a less invasive anterior intrapelvic approach is selected. Journal of Bone and Joint Surgery, Inc. 2020-07-15 2020-03-23 /pmc/articles/PMC7508287/ /pubmed/32675678 http://dx.doi.org/10.2106/JBJS.19.01027 Text en Copyright © 2020 The Authors. Published by The Journal of Bone and Joint Surgery, Incorporated All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Scientific Articles
Chen, Kaifang
Yang, Fan
Yao, Sheng
Xiong, Zekang
Sun, Tingfang
Guo, Xiaodong
Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title_full Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title_fullStr Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title_full_unstemmed Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title_short Biomechanical Comparison of Different Fixation Techniques for Typical Acetabular Fractures in the Elderly: The Role of Special Quadrilateral Surface Buttress Plates
title_sort biomechanical comparison of different fixation techniques for typical acetabular fractures in the elderly: the role of special quadrilateral surface buttress plates
topic Scientific Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7508287/
https://www.ncbi.nlm.nih.gov/pubmed/32675678
http://dx.doi.org/10.2106/JBJS.19.01027
work_keys_str_mv AT chenkaifang biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates
AT yangfan biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates
AT yaosheng biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates
AT xiongzekang biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates
AT suntingfang biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates
AT guoxiaodong biomechanicalcomparisonofdifferentfixationtechniquesfortypicalacetabularfracturesintheelderlytheroleofspecialquadrilateralsurfacebuttressplates