Cargando…

Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation

BACKGROUND: The peripheral perfusion index (PI), as a real-time bedside indicator of peripheral tissue perfusion, may be useful for determining mean arterial pressure (MAP) after early resuscitation of septic shock patients. The aim of this study was to explore the response of PI to norepinephrine (...

Descripción completa

Detalles Bibliográficos
Autores principales: He, Huai-Wu, Liu, Wang-Lin, Zhou, Xiang, Long, Yun, Liu, Da-Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7508439/
https://www.ncbi.nlm.nih.gov/pubmed/32842018
http://dx.doi.org/10.1097/CM9.0000000000001017
_version_ 1783585421588955136
author He, Huai-Wu
Liu, Wang-Lin
Zhou, Xiang
Long, Yun
Liu, Da-Wei
author_facet He, Huai-Wu
Liu, Wang-Lin
Zhou, Xiang
Long, Yun
Liu, Da-Wei
author_sort He, Huai-Wu
collection PubMed
description BACKGROUND: The peripheral perfusion index (PI), as a real-time bedside indicator of peripheral tissue perfusion, may be useful for determining mean arterial pressure (MAP) after early resuscitation of septic shock patients. The aim of this study was to explore the response of PI to norepinephrine (NE)-induced changes in MAP. METHODS: Twenty septic shock patients with pulse-induced contour cardiac output catheter, who had usual MAP under NE infusion after early resuscitation, were enrolled in this prospective, open-label study. Three MAP levels (usual MAP −10 mmHg, usual MAP, and usual MAP +10 mmHg) were obtained by NE titration, and the corresponding global hemodynamic parameters and PI were recorded. The general linear model with repeated measures was used for analysis of variance of related parameters at three MAP levels. RESULTS: With increasing NE infusion, significant changes were found in MAP (F = 502.46, P < 0.001) and central venous pressure (F = 27.45, P < 0.001) during NE titration. However, there was not a significant and consistent change in continuous cardiac output (CO) (F = 0.41, P = 0.720) and PI (F = 0.73, P = 0.482) at different MAP levels. Of the 20 patients enrolled, seven reached the maximum PI value at usual MAP −10 mmHg, three reached the maximum PI value at usual MAP, and ten reached the maximum PI value at usual MAP +10 mmHg. The change in PI was not significantly correlated with the change in CO (r = 0.260, P = 0.269) from usual MAP −10 mmHg to usual MAP. There was also no significant correlation between the change in PI and change in CO (r = 0.084, P = 0.726) from usual MAP to usual MAP +10 mmHg. CONCLUSIONS: Differing MAP levels by NE infusion induced diverse PI responses in septic shock patients, and these PI responses may be independent of the change in CO. PI may have potential applications for MAP optimization based on changes in peripheral tissue perfusion.
format Online
Article
Text
id pubmed-7508439
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-75084392020-10-14 Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation He, Huai-Wu Liu, Wang-Lin Zhou, Xiang Long, Yun Liu, Da-Wei Chin Med J (Engl) Original Articles BACKGROUND: The peripheral perfusion index (PI), as a real-time bedside indicator of peripheral tissue perfusion, may be useful for determining mean arterial pressure (MAP) after early resuscitation of septic shock patients. The aim of this study was to explore the response of PI to norepinephrine (NE)-induced changes in MAP. METHODS: Twenty septic shock patients with pulse-induced contour cardiac output catheter, who had usual MAP under NE infusion after early resuscitation, were enrolled in this prospective, open-label study. Three MAP levels (usual MAP −10 mmHg, usual MAP, and usual MAP +10 mmHg) were obtained by NE titration, and the corresponding global hemodynamic parameters and PI were recorded. The general linear model with repeated measures was used for analysis of variance of related parameters at three MAP levels. RESULTS: With increasing NE infusion, significant changes were found in MAP (F = 502.46, P < 0.001) and central venous pressure (F = 27.45, P < 0.001) during NE titration. However, there was not a significant and consistent change in continuous cardiac output (CO) (F = 0.41, P = 0.720) and PI (F = 0.73, P = 0.482) at different MAP levels. Of the 20 patients enrolled, seven reached the maximum PI value at usual MAP −10 mmHg, three reached the maximum PI value at usual MAP, and ten reached the maximum PI value at usual MAP +10 mmHg. The change in PI was not significantly correlated with the change in CO (r = 0.260, P = 0.269) from usual MAP −10 mmHg to usual MAP. There was also no significant correlation between the change in PI and change in CO (r = 0.084, P = 0.726) from usual MAP to usual MAP +10 mmHg. CONCLUSIONS: Differing MAP levels by NE infusion induced diverse PI responses in septic shock patients, and these PI responses may be independent of the change in CO. PI may have potential applications for MAP optimization based on changes in peripheral tissue perfusion. Lippincott Williams & Wilkins 2020-09-20 2020-08-24 /pmc/articles/PMC7508439/ /pubmed/32842018 http://dx.doi.org/10.1097/CM9.0000000000001017 Text en Copyright © 2020 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Original Articles
He, Huai-Wu
Liu, Wang-Lin
Zhou, Xiang
Long, Yun
Liu, Da-Wei
Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title_full Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title_fullStr Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title_full_unstemmed Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title_short Effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
title_sort effect of mean arterial pressure change by norepinephrine on peripheral perfusion index in septic shock patients after early resuscitation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7508439/
https://www.ncbi.nlm.nih.gov/pubmed/32842018
http://dx.doi.org/10.1097/CM9.0000000000001017
work_keys_str_mv AT hehuaiwu effectofmeanarterialpressurechangebynorepinephrineonperipheralperfusionindexinsepticshockpatientsafterearlyresuscitation
AT liuwanglin effectofmeanarterialpressurechangebynorepinephrineonperipheralperfusionindexinsepticshockpatientsafterearlyresuscitation
AT zhouxiang effectofmeanarterialpressurechangebynorepinephrineonperipheralperfusionindexinsepticshockpatientsafterearlyresuscitation
AT longyun effectofmeanarterialpressurechangebynorepinephrineonperipheralperfusionindexinsepticshockpatientsafterearlyresuscitation
AT liudawei effectofmeanarterialpressurechangebynorepinephrineonperipheralperfusionindexinsepticshockpatientsafterearlyresuscitation