Cargando…

Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots

The Stent retriever Assisted Vacuum-locked Extraction (SAVE) technique in mechanical thrombectomy consists of the simultaneous use of a stent retriever and a distal aspiration catheter, with the removal of both as a unit when performing the thrombectomy pass. This is a safe procedure that provides a...

Descripción completa

Detalles Bibliográficos
Autores principales: Moreu, M, Pérez-García, C, Gómez-Escalonilla, C, Rosati, S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7509522/
https://www.ncbi.nlm.nih.gov/pubmed/32586911
http://dx.doi.org/10.1136/neurintsurg-2020-016061
_version_ 1783585614400061440
author Moreu, M
Pérez-García, C
Gómez-Escalonilla, C
Rosati, S
author_facet Moreu, M
Pérez-García, C
Gómez-Escalonilla, C
Rosati, S
author_sort Moreu, M
collection PubMed
description The Stent retriever Assisted Vacuum-locked Extraction (SAVE) technique in mechanical thrombectomy consists of the simultaneous use of a stent retriever and a distal aspiration catheter, with the removal of both as a unit when performing the thrombectomy pass. This is a safe procedure that provides a high rate of first-pass reperfusion.1 In the distal M1 segment of the middle cerebral artery (MCA) occlusions, with the distal portion of the clot extending to the upper and lower MCA branches, mechanical thrombectomy can be challenging since the thrombus is not fully trapped, with risk of distal clot migration to the branch in which the retriever is not placed. In these cases the double stent-retriever technique has been described as a rescue strategy.2–4 We describe a case of the combined use of SAVE and double stent-retriever techniques as a rescue strategy in a patient with tandem occlusion of the proximal internal carotid artery and distal MCA—the D-SAVE technique. (video 1)
format Online
Article
Text
id pubmed-7509522
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-75095222020-10-05 Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots Moreu, M Pérez-García, C Gómez-Escalonilla, C Rosati, S J Neurointerv Surg Technical Video The Stent retriever Assisted Vacuum-locked Extraction (SAVE) technique in mechanical thrombectomy consists of the simultaneous use of a stent retriever and a distal aspiration catheter, with the removal of both as a unit when performing the thrombectomy pass. This is a safe procedure that provides a high rate of first-pass reperfusion.1 In the distal M1 segment of the middle cerebral artery (MCA) occlusions, with the distal portion of the clot extending to the upper and lower MCA branches, mechanical thrombectomy can be challenging since the thrombus is not fully trapped, with risk of distal clot migration to the branch in which the retriever is not placed. In these cases the double stent-retriever technique has been described as a rescue strategy.2–4 We describe a case of the combined use of SAVE and double stent-retriever techniques as a rescue strategy in a patient with tandem occlusion of the proximal internal carotid artery and distal MCA—the D-SAVE technique. (video 1) BMJ Publishing Group 2020-10 2020-06-25 /pmc/articles/PMC7509522/ /pubmed/32586911 http://dx.doi.org/10.1136/neurintsurg-2020-016061 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Technical Video
Moreu, M
Pérez-García, C
Gómez-Escalonilla, C
Rosati, S
Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title_full Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title_fullStr Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title_full_unstemmed Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title_short Dual SAVE technique for mechanical thrombectomy rescue on MCA bifurcation clots
title_sort dual save technique for mechanical thrombectomy rescue on mca bifurcation clots
topic Technical Video
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7509522/
https://www.ncbi.nlm.nih.gov/pubmed/32586911
http://dx.doi.org/10.1136/neurintsurg-2020-016061
work_keys_str_mv AT moreum dualsavetechniqueformechanicalthrombectomyrescueonmcabifurcationclots
AT perezgarciac dualsavetechniqueformechanicalthrombectomyrescueonmcabifurcationclots
AT gomezescalonillac dualsavetechniqueformechanicalthrombectomyrescueonmcabifurcationclots
AT rosatis dualsavetechniqueformechanicalthrombectomyrescueonmcabifurcationclots