Cargando…

Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas

BACKGROUND: Glioma is the most common fatal malignant tumor of the CNS. Early detection of glioma grades based on diffusion-weighted imaging (DWI) properties is considered one of the most recent noninvasive promising tools in the assessment of glioma grade and could be helpful in monitoring patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Agha, Mansour, Abushab, Khaled, Quffa, Khetam, Al-Agha, Samy, Alajerami, Yasser, Tabash, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7509551/
https://www.ncbi.nlm.nih.gov/pubmed/33005190
http://dx.doi.org/10.1155/2020/6942406
_version_ 1783585621242019840
author Al-Agha, Mansour
Abushab, Khaled
Quffa, Khetam
Al-Agha, Samy
Alajerami, Yasser
Tabash, Mohammed
author_facet Al-Agha, Mansour
Abushab, Khaled
Quffa, Khetam
Al-Agha, Samy
Alajerami, Yasser
Tabash, Mohammed
author_sort Al-Agha, Mansour
collection PubMed
description BACKGROUND: Glioma is the most common fatal malignant tumor of the CNS. Early detection of glioma grades based on diffusion-weighted imaging (DWI) properties is considered one of the most recent noninvasive promising tools in the assessment of glioma grade and could be helpful in monitoring patient prognosis and response to therapy. AIM: This study aimed to investigate the accuracy of DWI at both standard and high b values (b = 1000 s/mm(2) and b = 3000 s/mm(2)) to distinguish high-grade glioma (HGG) from low-grade glioma (LGG) in clinical practice based on histopathological results. MATERIALS AND METHODS: Twenty-three patients with glioma had DWI at l.5 T MR using two different b values (b = 1000 s/mm(2) and b = 3000 s/mm(2)) at Al-Shifa Medical Complex after obtaining ethical and administrative approvals, and data were collected from March 2019 to March 2020. Minimum, maximum, and mean of apparent diffusion coefficient (ADC) values were measured through drawing region of interest (ROI) on a solid part at ADC maps. Data were analyzed by using the MedCalc analysis program, version 19.0.4, receiver operating characteristic (ROC) curve analysis was done, and optimal cutoff values for grading gliomas were determined. Sensitivity and specificity were also calculated. RESULTS: The obtained results showed the ADC(mean), ADC(ratio), ADC(max), and ADC(min) were performed to differentiate between LGG and HGG at both standard and high b values. Moreover, ADC values were inversely proportional to glioma grade, and these differences are more obvious at high b value. Minimum ADC values using standard b value were 1.13 ± 0.17 × 10(−3) mm(2)/s, 0.89 ± 0.85 × 10(−3) mm(2)/s, and 0.82 ± 0.17 × 10(−3) mm(2)/s for grades II, III, and IV, respectively. Concerning high b value, ADC(min) values were 0.76 ± 0.07 × 10(−3) mm(2)/s, 0.61 ± 0.01 × 10(−3) mm(2)/s, and 0.48 ± 0.07 × 10(−3) mm(2)/s for grades II, III, and IV, respectively. ADC values were inversely correlated with results of glioma grades, and the correlation was stronger at ADC(3000) (r = −0.722, P ≤ 0.001). The ADC(3000) achieved the highest diagnostic accuracy with an area under the curve (AUC) of 0.618, 100% sensitivity, 85.7% specificity, and 85.7% accuracy for glioma grading at a cutoff point of ≤0.618 × 10(−3) mm(2)/s. The high b value showed stronger agreement with histopathology compared with standard b value results (k = 0.89 and 0.79), respectively. CONCLUSION: The ADC values decrease with an increase in tumor cellularity. Meanwhile, high b value provides better tissue contrast by reflecting more tissue diffusivity. Therefore, ADC-derived parameters at high b value are more useful in the grading of glioma than those obtained at standard b value. They might be a better surrogate imaging sequence in the preoperative evaluation of gliomas.
format Online
Article
Text
id pubmed-7509551
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-75095512020-09-30 Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas Al-Agha, Mansour Abushab, Khaled Quffa, Khetam Al-Agha, Samy Alajerami, Yasser Tabash, Mohammed J Oncol Research Article BACKGROUND: Glioma is the most common fatal malignant tumor of the CNS. Early detection of glioma grades based on diffusion-weighted imaging (DWI) properties is considered one of the most recent noninvasive promising tools in the assessment of glioma grade and could be helpful in monitoring patient prognosis and response to therapy. AIM: This study aimed to investigate the accuracy of DWI at both standard and high b values (b = 1000 s/mm(2) and b = 3000 s/mm(2)) to distinguish high-grade glioma (HGG) from low-grade glioma (LGG) in clinical practice based on histopathological results. MATERIALS AND METHODS: Twenty-three patients with glioma had DWI at l.5 T MR using two different b values (b = 1000 s/mm(2) and b = 3000 s/mm(2)) at Al-Shifa Medical Complex after obtaining ethical and administrative approvals, and data were collected from March 2019 to March 2020. Minimum, maximum, and mean of apparent diffusion coefficient (ADC) values were measured through drawing region of interest (ROI) on a solid part at ADC maps. Data were analyzed by using the MedCalc analysis program, version 19.0.4, receiver operating characteristic (ROC) curve analysis was done, and optimal cutoff values for grading gliomas were determined. Sensitivity and specificity were also calculated. RESULTS: The obtained results showed the ADC(mean), ADC(ratio), ADC(max), and ADC(min) were performed to differentiate between LGG and HGG at both standard and high b values. Moreover, ADC values were inversely proportional to glioma grade, and these differences are more obvious at high b value. Minimum ADC values using standard b value were 1.13 ± 0.17 × 10(−3) mm(2)/s, 0.89 ± 0.85 × 10(−3) mm(2)/s, and 0.82 ± 0.17 × 10(−3) mm(2)/s for grades II, III, and IV, respectively. Concerning high b value, ADC(min) values were 0.76 ± 0.07 × 10(−3) mm(2)/s, 0.61 ± 0.01 × 10(−3) mm(2)/s, and 0.48 ± 0.07 × 10(−3) mm(2)/s for grades II, III, and IV, respectively. ADC values were inversely correlated with results of glioma grades, and the correlation was stronger at ADC(3000) (r = −0.722, P ≤ 0.001). The ADC(3000) achieved the highest diagnostic accuracy with an area under the curve (AUC) of 0.618, 100% sensitivity, 85.7% specificity, and 85.7% accuracy for glioma grading at a cutoff point of ≤0.618 × 10(−3) mm(2)/s. The high b value showed stronger agreement with histopathology compared with standard b value results (k = 0.89 and 0.79), respectively. CONCLUSION: The ADC values decrease with an increase in tumor cellularity. Meanwhile, high b value provides better tissue contrast by reflecting more tissue diffusivity. Therefore, ADC-derived parameters at high b value are more useful in the grading of glioma than those obtained at standard b value. They might be a better surrogate imaging sequence in the preoperative evaluation of gliomas. Hindawi 2020-09-14 /pmc/articles/PMC7509551/ /pubmed/33005190 http://dx.doi.org/10.1155/2020/6942406 Text en Copyright © 2020 Mansour Al-Agha et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Al-Agha, Mansour
Abushab, Khaled
Quffa, Khetam
Al-Agha, Samy
Alajerami, Yasser
Tabash, Mohammed
Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title_full Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title_fullStr Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title_full_unstemmed Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title_short Efficiency of High and Standard b Value Diffusion-Weighted Magnetic Resonance Imaging in Grading of Gliomas
title_sort efficiency of high and standard b value diffusion-weighted magnetic resonance imaging in grading of gliomas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7509551/
https://www.ncbi.nlm.nih.gov/pubmed/33005190
http://dx.doi.org/10.1155/2020/6942406
work_keys_str_mv AT alaghamansour efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas
AT abushabkhaled efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas
AT quffakhetam efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas
AT alaghasamy efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas
AT alajeramiyasser efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas
AT tabashmohammed efficiencyofhighandstandardbvaluediffusionweightedmagneticresonanceimagingingradingofgliomas