Cargando…

Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report

BACKGROUND: Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcath...

Descripción completa

Detalles Bibliográficos
Autores principales: Kmiec, Lukasz, Holzamer, Andreas, Fischer, Marcus, Debl, Kurt, Zerdzitzki, Matthäus, Schmid, Christof, Maier, Lars, Hilker, Michael, Sossalla, Samuel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7510274/
https://www.ncbi.nlm.nih.gov/pubmed/32962754
http://dx.doi.org/10.1186/s13256-020-02474-x
_version_ 1783585754035781632
author Kmiec, Lukasz
Holzamer, Andreas
Fischer, Marcus
Debl, Kurt
Zerdzitzki, Matthäus
Schmid, Christof
Maier, Lars
Hilker, Michael
Sossalla, Samuel
author_facet Kmiec, Lukasz
Holzamer, Andreas
Fischer, Marcus
Debl, Kurt
Zerdzitzki, Matthäus
Schmid, Christof
Maier, Lars
Hilker, Michael
Sossalla, Samuel
author_sort Kmiec, Lukasz
collection PubMed
description BACKGROUND: Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcatheter aortic valve replacement and eventually concomitant complex percutaneous coronary intervention. CASE PRESENTATION: We present a successful procedure of transcatheter aortic valve replacement and high-risk percutaneous coronary intervention utilizing venoarterial extracorporeal membrane oxygenation for hemodynamic support in a very frail 88-year-old Caucasian woman with severe symptomatic aortic stenosis and coronary bypass grafting in the past. Echocardiography revealed a “low-flow low-gradient” aortic stenosis (mean transvalvular gradient 30 mmHg, aortic valve area 0.4 cm(2), significant calcification), a left ventricular ejection fraction of 35%, severe mitral regurgitation with moderate stenosis (mean transvalvular gradient 7 mmHg), with a systolic pulmonary artery pressure of 80 mmHg. Moreover, pre-interventional coronary angiography exposed a severe left main ostial stenosis and sequential subtotal heavily calcified stenosis of the left anterior descending artery . Computed tomographic angiography showed no heavy tortuosity but moderate calcification of the iliofemoral arteries. The procedure was performed under general anesthesia in our hybrid operating room. Extracorporeal membrane oxygenation was established by left femoral percutaneous cannulation using a 21-Fr venous and 15-Fr arterial cannula. Subsequently, complex percutaneous coronary intervention with implantation of two drug-eluting stents from the left main into the left anterior descending artery was performed via a right femoral arterial 7F sheath. Thereafter, a 23-mm Sapien 3 aortic valve prosthesis (Edwards, Irvine, CA, USA) was implanted via right femoral artery in the usual manner, whereby the arterial pigtail catheter for marking the aortic annulus during transcatheter aortic valve replacement was inserted over a Check-Flo® Hemostasis Assembly (Cook Medical, Bloomington, IN, USA) on a Y-adapter via the arterial extracorporeal membrane oxygenation cannula. After extracorporeal membrane oxygenation decannulation, vascular closure was easily performed using the MANTA vascular closure device in order to reduce procedural time and risk of access site complications. CONCLUSIONS: In summary, we demonstrate the feasibility of elective prophylactic extracorporeal membrane oxygenation implementation in selected very high-risk and frail patients undergoing transcatheter aortic valve replacement and percutaneous coronary intervention in order to avoid intraprocedural complications.
format Online
Article
Text
id pubmed-7510274
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-75102742020-09-25 Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report Kmiec, Lukasz Holzamer, Andreas Fischer, Marcus Debl, Kurt Zerdzitzki, Matthäus Schmid, Christof Maier, Lars Hilker, Michael Sossalla, Samuel J Med Case Rep Case Report BACKGROUND: Transcatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcatheter aortic valve replacement and eventually concomitant complex percutaneous coronary intervention. CASE PRESENTATION: We present a successful procedure of transcatheter aortic valve replacement and high-risk percutaneous coronary intervention utilizing venoarterial extracorporeal membrane oxygenation for hemodynamic support in a very frail 88-year-old Caucasian woman with severe symptomatic aortic stenosis and coronary bypass grafting in the past. Echocardiography revealed a “low-flow low-gradient” aortic stenosis (mean transvalvular gradient 30 mmHg, aortic valve area 0.4 cm(2), significant calcification), a left ventricular ejection fraction of 35%, severe mitral regurgitation with moderate stenosis (mean transvalvular gradient 7 mmHg), with a systolic pulmonary artery pressure of 80 mmHg. Moreover, pre-interventional coronary angiography exposed a severe left main ostial stenosis and sequential subtotal heavily calcified stenosis of the left anterior descending artery . Computed tomographic angiography showed no heavy tortuosity but moderate calcification of the iliofemoral arteries. The procedure was performed under general anesthesia in our hybrid operating room. Extracorporeal membrane oxygenation was established by left femoral percutaneous cannulation using a 21-Fr venous and 15-Fr arterial cannula. Subsequently, complex percutaneous coronary intervention with implantation of two drug-eluting stents from the left main into the left anterior descending artery was performed via a right femoral arterial 7F sheath. Thereafter, a 23-mm Sapien 3 aortic valve prosthesis (Edwards, Irvine, CA, USA) was implanted via right femoral artery in the usual manner, whereby the arterial pigtail catheter for marking the aortic annulus during transcatheter aortic valve replacement was inserted over a Check-Flo® Hemostasis Assembly (Cook Medical, Bloomington, IN, USA) on a Y-adapter via the arterial extracorporeal membrane oxygenation cannula. After extracorporeal membrane oxygenation decannulation, vascular closure was easily performed using the MANTA vascular closure device in order to reduce procedural time and risk of access site complications. CONCLUSIONS: In summary, we demonstrate the feasibility of elective prophylactic extracorporeal membrane oxygenation implementation in selected very high-risk and frail patients undergoing transcatheter aortic valve replacement and percutaneous coronary intervention in order to avoid intraprocedural complications. BioMed Central 2020-09-23 /pmc/articles/PMC7510274/ /pubmed/32962754 http://dx.doi.org/10.1186/s13256-020-02474-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Kmiec, Lukasz
Holzamer, Andreas
Fischer, Marcus
Debl, Kurt
Zerdzitzki, Matthäus
Schmid, Christof
Maier, Lars
Hilker, Michael
Sossalla, Samuel
Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_full Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_fullStr Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_full_unstemmed Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_short Protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
title_sort protected complex percutaneous coronary intervention and transcatheter aortic valve replacement using extracorporeal membrane oxygenation in a high-risk frail patient: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7510274/
https://www.ncbi.nlm.nih.gov/pubmed/32962754
http://dx.doi.org/10.1186/s13256-020-02474-x
work_keys_str_mv AT kmieclukasz protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT holzamerandreas protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT fischermarcus protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT deblkurt protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT zerdzitzkimatthaus protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT schmidchristof protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT maierlars protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT hilkermichael protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport
AT sossallasamuel protectedcomplexpercutaneouscoronaryinterventionandtranscatheteraorticvalvereplacementusingextracorporealmembraneoxygenationinahighriskfrailpatientacasereport