Cargando…

PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening

Precise monitoring of specific biomarkers in biological fluids with accurate biodiagnostic sensors is critical for early diagnosis of diseases and subsequent treatment planning. In this work, we demonstrated an innovative biodiagnostic sensor, portable reusable accurate diagnostics with nanostar ant...

Descripción completa

Detalles Bibliográficos
Autores principales: Wen, Xiaona, Ou, Yu‐Chuan, Zarick, Holly F., Zhang, Xin, Hmelo, Anthony B., Victor, Quinton J., Paul, Eden P., Slocik, Joseph M., Naik, Rajesh R., Bellan, Leon M., Lin, Eugene C., Bardhan, Rizia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7510456/
https://www.ncbi.nlm.nih.gov/pubmed/33005736
http://dx.doi.org/10.1002/btm2.10165
_version_ 1783585791597871104
author Wen, Xiaona
Ou, Yu‐Chuan
Zarick, Holly F.
Zhang, Xin
Hmelo, Anthony B.
Victor, Quinton J.
Paul, Eden P.
Slocik, Joseph M.
Naik, Rajesh R.
Bellan, Leon M.
Lin, Eugene C.
Bardhan, Rizia
author_facet Wen, Xiaona
Ou, Yu‐Chuan
Zarick, Holly F.
Zhang, Xin
Hmelo, Anthony B.
Victor, Quinton J.
Paul, Eden P.
Slocik, Joseph M.
Naik, Rajesh R.
Bellan, Leon M.
Lin, Eugene C.
Bardhan, Rizia
author_sort Wen, Xiaona
collection PubMed
description Precise monitoring of specific biomarkers in biological fluids with accurate biodiagnostic sensors is critical for early diagnosis of diseases and subsequent treatment planning. In this work, we demonstrated an innovative biodiagnostic sensor, portable reusable accurate diagnostics with nanostar antennas (PRADA), for multiplexed biomarker detection in small volumes (~50 μl) enabled in a microfluidic platform. Here, PRADA simultaneously detected two biomarkers of myocardial infarction, cardiac troponin I (cTnI), which is well accepted for cardiac disorders, and neuropeptide Y (NPY), which controls cardiac sympathetic drive. In PRADA immunoassay, magnetic beads captured the biomarkers in human serum samples, and gold nanostars (GNSs) “antennas” labeled with peptide biorecognition elements and Raman tags detected the biomarkers via surface‐enhanced Raman spectroscopy (SERS). The peptide‐conjugated GNS‐SERS barcodes were leveraged to achieve high sensitivity, with a limit of detection (LOD) of 0.0055 ng/ml of cTnI, and a LOD of 0.12 ng/ml of NPY comparable with commercially available test kits. The innovation of PRADA was also in the regeneration and reuse of the same sensor chip for ~14 cycles. We validated PRADA by testing cTnI in 11 de‐identified cardiac patient samples of various demographics within a 95% confidence interval and high precision profile. We envision low‐cost PRADA will have tremendous translational impact and be amenable to resource‐limited settings for accurate treatment planning in patients.
format Online
Article
Text
id pubmed-7510456
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-75104562020-09-30 PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening Wen, Xiaona Ou, Yu‐Chuan Zarick, Holly F. Zhang, Xin Hmelo, Anthony B. Victor, Quinton J. Paul, Eden P. Slocik, Joseph M. Naik, Rajesh R. Bellan, Leon M. Lin, Eugene C. Bardhan, Rizia Bioeng Transl Med Research Reports Precise monitoring of specific biomarkers in biological fluids with accurate biodiagnostic sensors is critical for early diagnosis of diseases and subsequent treatment planning. In this work, we demonstrated an innovative biodiagnostic sensor, portable reusable accurate diagnostics with nanostar antennas (PRADA), for multiplexed biomarker detection in small volumes (~50 μl) enabled in a microfluidic platform. Here, PRADA simultaneously detected two biomarkers of myocardial infarction, cardiac troponin I (cTnI), which is well accepted for cardiac disorders, and neuropeptide Y (NPY), which controls cardiac sympathetic drive. In PRADA immunoassay, magnetic beads captured the biomarkers in human serum samples, and gold nanostars (GNSs) “antennas” labeled with peptide biorecognition elements and Raman tags detected the biomarkers via surface‐enhanced Raman spectroscopy (SERS). The peptide‐conjugated GNS‐SERS barcodes were leveraged to achieve high sensitivity, with a limit of detection (LOD) of 0.0055 ng/ml of cTnI, and a LOD of 0.12 ng/ml of NPY comparable with commercially available test kits. The innovation of PRADA was also in the regeneration and reuse of the same sensor chip for ~14 cycles. We validated PRADA by testing cTnI in 11 de‐identified cardiac patient samples of various demographics within a 95% confidence interval and high precision profile. We envision low‐cost PRADA will have tremendous translational impact and be amenable to resource‐limited settings for accurate treatment planning in patients. John Wiley & Sons, Inc. 2020-05-15 /pmc/articles/PMC7510456/ /pubmed/33005736 http://dx.doi.org/10.1002/btm2.10165 Text en © 2020 The Authors. Bioengineering & Translational Medicine published by Wiley Periodicals LLC on behalf of The American Institute of Chemical Engineers. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Reports
Wen, Xiaona
Ou, Yu‐Chuan
Zarick, Holly F.
Zhang, Xin
Hmelo, Anthony B.
Victor, Quinton J.
Paul, Eden P.
Slocik, Joseph M.
Naik, Rajesh R.
Bellan, Leon M.
Lin, Eugene C.
Bardhan, Rizia
PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title_full PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title_fullStr PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title_full_unstemmed PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title_short PRADA: Portable Reusable Accurate Diagnostics with nanostar Antennas for multiplexed biomarker screening
title_sort prada: portable reusable accurate diagnostics with nanostar antennas for multiplexed biomarker screening
topic Research Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7510456/
https://www.ncbi.nlm.nih.gov/pubmed/33005736
http://dx.doi.org/10.1002/btm2.10165
work_keys_str_mv AT wenxiaona pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT ouyuchuan pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT zarickhollyf pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT zhangxin pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT hmeloanthonyb pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT victorquintonj pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT pauledenp pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT slocikjosephm pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT naikrajeshr pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT bellanleonm pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT lineugenec pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening
AT bardhanrizia pradaportablereusableaccuratediagnosticswithnanostarantennasformultiplexedbiomarkerscreening