Cargando…

Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength

INTRODUCTION: Progression of muscle strength weakening will lead to a poor physical performance and disability. While this is particularly important in patients with diabetes, the associations of reduced muscle strength measured by grip strength with clinical features and physical performance remain...

Descripción completa

Detalles Bibliográficos
Autores principales: Yokoyama, Hiroki, Shiraiwa, Toshihiko, Takahara, Mitsuyoshi, Iwamoto, Masahiro, Kuribayashi, Nobuichi, Nomura, Takuo, Yamada, Minoru, Sone, Hirohito, Araki, Shin-ichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7511604/
https://www.ncbi.nlm.nih.gov/pubmed/32948539
http://dx.doi.org/10.1136/bmjdrc-2020-001562
_version_ 1783585989153783808
author Yokoyama, Hiroki
Shiraiwa, Toshihiko
Takahara, Mitsuyoshi
Iwamoto, Masahiro
Kuribayashi, Nobuichi
Nomura, Takuo
Yamada, Minoru
Sone, Hirohito
Araki, Shin-ichi
author_facet Yokoyama, Hiroki
Shiraiwa, Toshihiko
Takahara, Mitsuyoshi
Iwamoto, Masahiro
Kuribayashi, Nobuichi
Nomura, Takuo
Yamada, Minoru
Sone, Hirohito
Araki, Shin-ichi
author_sort Yokoyama, Hiroki
collection PubMed
description INTRODUCTION: Progression of muscle strength weakening will lead to a poor physical performance and disability. While this is particularly important in patients with diabetes, the associations of reduced muscle strength measured by grip strength with clinical features and physical performance remain unclear. We investigated clinical features and physical performance measures in association with grip strength in elderly people with diabetes in a primary care setting. RESEARCH DESIGN AND METHODS: A cross-sectional study was conducted enrolling 634 male and 323 female Japanese patients with type 2 diabetes aged 60 years or older. First, grip strength was measured and the associations of gender-specific grip strength with clinical features were evaluated. Second, in patients with a grip strength below the gender-specific median, physical performance measures, including gait speed, timed chair stand speed, knee extension strength, standing balance, and short physical performance battery scores, were investigated. Patients with and without a low performance defined by Asian Working Group for Sarcopenia were compared in terms of clinical features and physical performance measures. RESULTS: Grip strength decreased according to aging and longer duration of diabetes and was independently related to body mass index, glycated hemoglobin A1c (HbA1c), serum albumin, albuminuria, neuropathy, and stroke in male patients, and to body mass index and albuminuria in female patients. The physical performance measures became worse proportionally to a decrease in the grip strength. Patients with a low performance exhibited a significantly older age, lower grip strength and serum albumin, higher albuminuria, and poorer physical performance measures than those without. CONCLUSIONS: Reduced grip strength was associated with glycemic exposure indicators of age-related duration, HbA1c, and vascular complications. The physical performance measures became worse with decreasing grip strength. Measurements of grip strength and physical performance in patients with diabetes may help promote intervention to prevent frailty in future studies.
format Online
Article
Text
id pubmed-7511604
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-75116042020-10-05 Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength Yokoyama, Hiroki Shiraiwa, Toshihiko Takahara, Mitsuyoshi Iwamoto, Masahiro Kuribayashi, Nobuichi Nomura, Takuo Yamada, Minoru Sone, Hirohito Araki, Shin-ichi BMJ Open Diabetes Res Care Clinical care/Education/Nutrition INTRODUCTION: Progression of muscle strength weakening will lead to a poor physical performance and disability. While this is particularly important in patients with diabetes, the associations of reduced muscle strength measured by grip strength with clinical features and physical performance remain unclear. We investigated clinical features and physical performance measures in association with grip strength in elderly people with diabetes in a primary care setting. RESEARCH DESIGN AND METHODS: A cross-sectional study was conducted enrolling 634 male and 323 female Japanese patients with type 2 diabetes aged 60 years or older. First, grip strength was measured and the associations of gender-specific grip strength with clinical features were evaluated. Second, in patients with a grip strength below the gender-specific median, physical performance measures, including gait speed, timed chair stand speed, knee extension strength, standing balance, and short physical performance battery scores, were investigated. Patients with and without a low performance defined by Asian Working Group for Sarcopenia were compared in terms of clinical features and physical performance measures. RESULTS: Grip strength decreased according to aging and longer duration of diabetes and was independently related to body mass index, glycated hemoglobin A1c (HbA1c), serum albumin, albuminuria, neuropathy, and stroke in male patients, and to body mass index and albuminuria in female patients. The physical performance measures became worse proportionally to a decrease in the grip strength. Patients with a low performance exhibited a significantly older age, lower grip strength and serum albumin, higher albuminuria, and poorer physical performance measures than those without. CONCLUSIONS: Reduced grip strength was associated with glycemic exposure indicators of age-related duration, HbA1c, and vascular complications. The physical performance measures became worse with decreasing grip strength. Measurements of grip strength and physical performance in patients with diabetes may help promote intervention to prevent frailty in future studies. BMJ Publishing Group 2020-09-18 /pmc/articles/PMC7511604/ /pubmed/32948539 http://dx.doi.org/10.1136/bmjdrc-2020-001562 Text en © Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Clinical care/Education/Nutrition
Yokoyama, Hiroki
Shiraiwa, Toshihiko
Takahara, Mitsuyoshi
Iwamoto, Masahiro
Kuribayashi, Nobuichi
Nomura, Takuo
Yamada, Minoru
Sone, Hirohito
Araki, Shin-ichi
Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title_full Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title_fullStr Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title_full_unstemmed Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title_short Applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
title_sort applications of physical performance measures to routine diabetes care for frailty prevention concept: fundamental data with grip strength, gait speed, timed chair stand speed, standing balance, and knee extension strength
topic Clinical care/Education/Nutrition
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7511604/
https://www.ncbi.nlm.nih.gov/pubmed/32948539
http://dx.doi.org/10.1136/bmjdrc-2020-001562
work_keys_str_mv AT yokoyamahiroki applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT shiraiwatoshihiko applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT takaharamitsuyoshi applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT iwamotomasahiro applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT kuribayashinobuichi applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT nomuratakuo applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT yamadaminoru applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT sonehirohito applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength
AT arakishinichi applicationsofphysicalperformancemeasurestoroutinediabetescareforfrailtypreventionconceptfundamentaldatawithgripstrengthgaitspeedtimedchairstandspeedstandingbalanceandkneeextensionstrength