Cargando…

Improved Calculation Model for the Shortest Spontaneous Combustion Period

[Image: see text] Disasters caused by the spontaneous combustion of coal have occurred in major coal-producing countries, resulting in the loss of resources and human life and severe environmental pollution. The development of an efficient model to calculate the shortest spontaneous combustion perio...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Yulong, Lin, Siyi, Hu, Wenhua, Yi, Shuping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512452/
https://www.ncbi.nlm.nih.gov/pubmed/32984675
http://dx.doi.org/10.1021/acsomega.0c01831
_version_ 1783586161348837376
author Gao, Yulong
Lin, Siyi
Hu, Wenhua
Yi, Shuping
author_facet Gao, Yulong
Lin, Siyi
Hu, Wenhua
Yi, Shuping
author_sort Gao, Yulong
collection PubMed
description [Image: see text] Disasters caused by the spontaneous combustion of coal have occurred in major coal-producing countries, resulting in the loss of resources and human life and severe environmental pollution. The development of an efficient model to calculate the shortest spontaneous combustion period (SSCP) has been a long-standing challenge. In this study, we propose a continuous model that calculates the SSCP by changing the traditional time summation form into a time integration form. The proposed model can reduce the calculation errors and determine the heating time to any temperature, which overcomes the limitations of the traditional model. The accuracy and convenience of the improved model were validated through a comparison with the results of the traditional model and a numerical model. The parameter sensitivities were analyzed in the improved model. The results showed that the SSCPs calculated using the improved continuous model are in good agreement with those of the traditional and numerical models. The results also indicated that the continuous model is more accurate and convenient than the traditional model. Parameters such as the heat release intensity, water content, specific heat capacity, and gas content influence the SSCP results in the sensitivity analysis. This model can potentially help prevent and control the risk of coal spontaneous combustion and should be further tested in practical mine management.
format Online
Article
Text
id pubmed-7512452
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-75124522020-09-25 Improved Calculation Model for the Shortest Spontaneous Combustion Period Gao, Yulong Lin, Siyi Hu, Wenhua Yi, Shuping ACS Omega [Image: see text] Disasters caused by the spontaneous combustion of coal have occurred in major coal-producing countries, resulting in the loss of resources and human life and severe environmental pollution. The development of an efficient model to calculate the shortest spontaneous combustion period (SSCP) has been a long-standing challenge. In this study, we propose a continuous model that calculates the SSCP by changing the traditional time summation form into a time integration form. The proposed model can reduce the calculation errors and determine the heating time to any temperature, which overcomes the limitations of the traditional model. The accuracy and convenience of the improved model were validated through a comparison with the results of the traditional model and a numerical model. The parameter sensitivities were analyzed in the improved model. The results showed that the SSCPs calculated using the improved continuous model are in good agreement with those of the traditional and numerical models. The results also indicated that the continuous model is more accurate and convenient than the traditional model. Parameters such as the heat release intensity, water content, specific heat capacity, and gas content influence the SSCP results in the sensitivity analysis. This model can potentially help prevent and control the risk of coal spontaneous combustion and should be further tested in practical mine management. American Chemical Society 2020-09-09 /pmc/articles/PMC7512452/ /pubmed/32984675 http://dx.doi.org/10.1021/acsomega.0c01831 Text en Copyright © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Gao, Yulong
Lin, Siyi
Hu, Wenhua
Yi, Shuping
Improved Calculation Model for the Shortest Spontaneous Combustion Period
title Improved Calculation Model for the Shortest Spontaneous Combustion Period
title_full Improved Calculation Model for the Shortest Spontaneous Combustion Period
title_fullStr Improved Calculation Model for the Shortest Spontaneous Combustion Period
title_full_unstemmed Improved Calculation Model for the Shortest Spontaneous Combustion Period
title_short Improved Calculation Model for the Shortest Spontaneous Combustion Period
title_sort improved calculation model for the shortest spontaneous combustion period
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512452/
https://www.ncbi.nlm.nih.gov/pubmed/32984675
http://dx.doi.org/10.1021/acsomega.0c01831
work_keys_str_mv AT gaoyulong improvedcalculationmodelfortheshortestspontaneouscombustionperiod
AT linsiyi improvedcalculationmodelfortheshortestspontaneouscombustionperiod
AT huwenhua improvedcalculationmodelfortheshortestspontaneouscombustionperiod
AT yishuping improvedcalculationmodelfortheshortestspontaneouscombustionperiod