Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle

To maximize the system-level heat integration, three retrofit concepts of waste heat recovery via organic Rankine cycle (ORC), in-depth boiler-turbine integration, and coupling of both are proposed, analyzed and comprehensively compared in terms of thermodynamic and economic performances. For thermo...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Shengwei, Li, Chengzhou, Tan, Tianyu, Fu, Peng, Wang, Ligang, Yang, Yongping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512652/
https://www.ncbi.nlm.nih.gov/pubmed/33265180
http://dx.doi.org/10.3390/e20020089
_version_ 1783586207677022208
author Huang, Shengwei
Li, Chengzhou
Tan, Tianyu
Fu, Peng
Wang, Ligang
Yang, Yongping
author_facet Huang, Shengwei
Li, Chengzhou
Tan, Tianyu
Fu, Peng
Wang, Ligang
Yang, Yongping
author_sort Huang, Shengwei
collection PubMed
description To maximize the system-level heat integration, three retrofit concepts of waste heat recovery via organic Rankine cycle (ORC), in-depth boiler-turbine integration, and coupling of both are proposed, analyzed and comprehensively compared in terms of thermodynamic and economic performances. For thermodynamic analysis, exergy analysis is employed with grand composite curves illustrated to identify how the systems are fundamentally and quantitatively improved, and to highlight key processes for system improvement. For economic analysis, annual revenue and investment payback period are calculated based on the estimation of capital investment of each component to identify the economic feasibility and competitiveness of each retrofit concept proposed. The results show that the in-depth boiler-turbine integration achieves a better temperature match of heat flows involved for different fluids and multi-stage air preheating, thus a significant improvement of power output (23.99 MW), which is much larger than that of the system with only ORC (6.49 MW). This is mainly due to the limitation of the ultra-low temperature (from 135 to 75 °C) heat available from the flue gas for ORC. The thermodynamic improvement is mostly contributed by the reduction of exergy destruction within the boiler subsystem, which is eventually converted to mechanical power; while the exergy destruction within the turbine system is almost not changed for the three concepts. The selection of ORC working fluids is performed to maximize the power output. Due to the low-grade heat source, the cycle with R11 offers the largest additional net power generation but is not significantly better than the other preselected working fluids. Economically, the in-depth boiler-turbine integration is the most economic completive solution with a payback period of only 0.78 year. The ORC concept is less attractive for a sole application due to a long payback time (2.26 years). However, by coupling both concepts, a net power output of 26.51 MW and a payback time of almost one year are achieved, which may promote the large-scale production and deployment of ORC with a cost reduction and competitiveness enhancement.
format Online
Article
Text
id pubmed-7512652
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75126522020-11-09 Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle Huang, Shengwei Li, Chengzhou Tan, Tianyu Fu, Peng Wang, Ligang Yang, Yongping Entropy (Basel) Article To maximize the system-level heat integration, three retrofit concepts of waste heat recovery via organic Rankine cycle (ORC), in-depth boiler-turbine integration, and coupling of both are proposed, analyzed and comprehensively compared in terms of thermodynamic and economic performances. For thermodynamic analysis, exergy analysis is employed with grand composite curves illustrated to identify how the systems are fundamentally and quantitatively improved, and to highlight key processes for system improvement. For economic analysis, annual revenue and investment payback period are calculated based on the estimation of capital investment of each component to identify the economic feasibility and competitiveness of each retrofit concept proposed. The results show that the in-depth boiler-turbine integration achieves a better temperature match of heat flows involved for different fluids and multi-stage air preheating, thus a significant improvement of power output (23.99 MW), which is much larger than that of the system with only ORC (6.49 MW). This is mainly due to the limitation of the ultra-low temperature (from 135 to 75 °C) heat available from the flue gas for ORC. The thermodynamic improvement is mostly contributed by the reduction of exergy destruction within the boiler subsystem, which is eventually converted to mechanical power; while the exergy destruction within the turbine system is almost not changed for the three concepts. The selection of ORC working fluids is performed to maximize the power output. Due to the low-grade heat source, the cycle with R11 offers the largest additional net power generation but is not significantly better than the other preselected working fluids. Economically, the in-depth boiler-turbine integration is the most economic completive solution with a payback period of only 0.78 year. The ORC concept is less attractive for a sole application due to a long payback time (2.26 years). However, by coupling both concepts, a net power output of 26.51 MW and a payback time of almost one year are achieved, which may promote the large-scale production and deployment of ORC with a cost reduction and competitiveness enhancement. MDPI 2018-01-29 /pmc/articles/PMC7512652/ /pubmed/33265180 http://dx.doi.org/10.3390/e20020089 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Shengwei
Li, Chengzhou
Tan, Tianyu
Fu, Peng
Wang, Ligang
Yang, Yongping
Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title_full Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title_fullStr Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title_full_unstemmed Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title_short Comparative Evaluation of Integrated Waste Heat Utilization Systems for Coal-Fired Power Plants Based on In-Depth Boiler-Turbine Integration and Organic Rankine Cycle
title_sort comparative evaluation of integrated waste heat utilization systems for coal-fired power plants based on in-depth boiler-turbine integration and organic rankine cycle
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512652/
https://www.ncbi.nlm.nih.gov/pubmed/33265180
http://dx.doi.org/10.3390/e20020089
work_keys_str_mv AT huangshengwei comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle
AT lichengzhou comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle
AT tantianyu comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle
AT fupeng comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle
AT wangligang comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle
AT yangyongping comparativeevaluationofintegratedwasteheatutilizationsystemsforcoalfiredpowerplantsbasedonindepthboilerturbineintegrationandorganicrankinecycle