Cargando…
Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis
Kurtogram can adaptively select the resonant frequency band, and then the characteristic fault frequency can be obtained by analyzing the selected band. However, the kurtogram is easily affected by random impulses and noise. In recent years, improvements to kurtogram have been concentrated on two as...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512908/ https://www.ncbi.nlm.nih.gov/pubmed/33265478 http://dx.doi.org/10.3390/e20050388 |
_version_ | 1783586265820561408 |
---|---|
author | Wan, Shuting Zhang, Xiong |
author_facet | Wan, Shuting Zhang, Xiong |
author_sort | Wan, Shuting |
collection | PubMed |
description | Kurtogram can adaptively select the resonant frequency band, and then the characteristic fault frequency can be obtained by analyzing the selected band. However, the kurtogram is easily affected by random impulses and noise. In recent years, improvements to kurtogram have been concentrated on two aspects: (a) the decomposition method of the frequency band; and (b) the selection index of the optimal frequency band. In this article, a new method called Teager Energy Entropy Ratio Gram (TEERgram) is proposed. The TEER algorithm takes the wavelet packet transform (WPT) as the signal frequency band decomposition method, which can adaptively segment the frequency band and control the noise. At the same time, Teager Energy Entropy Ratio (TEER) is proposed as a computing index for wavelet packet subbands. WPT has better decomposition properties than traditional finite impulse response (FIR) filtering and Fourier decomposition in the kurtogram algorithm. At the same time, TEER has better performance than the envelope spectrum or even the square envelope spectrum. Therefore, the TEERgram method can accurately identify the resonant frequency band under strong background noise. The effectiveness of the proposed method is verified by simulation and experimental analysis. |
format | Online Article Text |
id | pubmed-7512908 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-75129082020-11-09 Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis Wan, Shuting Zhang, Xiong Entropy (Basel) Article Kurtogram can adaptively select the resonant frequency band, and then the characteristic fault frequency can be obtained by analyzing the selected band. However, the kurtogram is easily affected by random impulses and noise. In recent years, improvements to kurtogram have been concentrated on two aspects: (a) the decomposition method of the frequency band; and (b) the selection index of the optimal frequency band. In this article, a new method called Teager Energy Entropy Ratio Gram (TEERgram) is proposed. The TEER algorithm takes the wavelet packet transform (WPT) as the signal frequency band decomposition method, which can adaptively segment the frequency band and control the noise. At the same time, Teager Energy Entropy Ratio (TEER) is proposed as a computing index for wavelet packet subbands. WPT has better decomposition properties than traditional finite impulse response (FIR) filtering and Fourier decomposition in the kurtogram algorithm. At the same time, TEER has better performance than the envelope spectrum or even the square envelope spectrum. Therefore, the TEERgram method can accurately identify the resonant frequency band under strong background noise. The effectiveness of the proposed method is verified by simulation and experimental analysis. MDPI 2018-05-21 /pmc/articles/PMC7512908/ /pubmed/33265478 http://dx.doi.org/10.3390/e20050388 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wan, Shuting Zhang, Xiong Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title | Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title_full | Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title_fullStr | Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title_full_unstemmed | Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title_short | Teager Energy Entropy Ratio of Wavelet Packet Transform and Its Application in Bearing Fault Diagnosis |
title_sort | teager energy entropy ratio of wavelet packet transform and its application in bearing fault diagnosis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7512908/ https://www.ncbi.nlm.nih.gov/pubmed/33265478 http://dx.doi.org/10.3390/e20050388 |
work_keys_str_mv | AT wanshuting teagerenergyentropyratioofwaveletpackettransformanditsapplicationinbearingfaultdiagnosis AT zhangxiong teagerenergyentropyratioofwaveletpackettransformanditsapplicationinbearingfaultdiagnosis |