Cargando…
Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report
Avascular necrosis and non-union are two most dreaded complications of femoral neck fracture fixations. Hip replacement seems to be a simple solution for this complex problem. However, the long-term efficacy of prosthetic replacement in the young population with higher functional demand is still que...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Malaysian Orthopaedic Association
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7513664/ https://www.ncbi.nlm.nih.gov/pubmed/32983389 http://dx.doi.org/10.5704/MOJ.2007.022 |
_version_ | 1783586429348085760 |
---|---|
author | Teh, KH Ruben, JK Chan, CK Abbas, AA |
author_facet | Teh, KH Ruben, JK Chan, CK Abbas, AA |
author_sort | Teh, KH |
collection | PubMed |
description | Avascular necrosis and non-union are two most dreaded complications of femoral neck fracture fixations. Hip replacement seems to be a simple solution for this complex problem. However, the long-term efficacy of prosthetic replacement in the young population with higher functional demand is still questionable. Femoral head preserving valgus subtrochanteric osteotomies in properly selected cases have strong support from literature. The conventional technique of valgus subtrochanteric osteotomy involves lateral based wedge resection. Alternatively, a simpler sliding oblique subtrochanteric osteotomy without any wedge removal can also be performed. We hereby describe a successful case of sliding subtrochanteric osteotomy with 135° dynamic hip screw (DHS) plate fixation in treating non-union neck of femur fracture in a young gentleman. |
format | Online Article Text |
id | pubmed-7513664 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Malaysian Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-75136642020-09-26 Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report Teh, KH Ruben, JK Chan, CK Abbas, AA Malays Orthop J Case Report Avascular necrosis and non-union are two most dreaded complications of femoral neck fracture fixations. Hip replacement seems to be a simple solution for this complex problem. However, the long-term efficacy of prosthetic replacement in the young population with higher functional demand is still questionable. Femoral head preserving valgus subtrochanteric osteotomies in properly selected cases have strong support from literature. The conventional technique of valgus subtrochanteric osteotomy involves lateral based wedge resection. Alternatively, a simpler sliding oblique subtrochanteric osteotomy without any wedge removal can also be performed. We hereby describe a successful case of sliding subtrochanteric osteotomy with 135° dynamic hip screw (DHS) plate fixation in treating non-union neck of femur fracture in a young gentleman. Malaysian Orthopaedic Association 2020-07 /pmc/articles/PMC7513664/ /pubmed/32983389 http://dx.doi.org/10.5704/MOJ.2007.022 Text en © 2020 Malaysian Orthopaedic Association (MOA). All Rights Reserved http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited |
spellingShingle | Case Report Teh, KH Ruben, JK Chan, CK Abbas, AA Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title | Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title_full | Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title_fullStr | Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title_full_unstemmed | Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title_short | Femoral Neck Non-Union - A Biomechanical Solution with Valgus Sliding Subtrochanteric Osteotomy: A Case Report |
title_sort | femoral neck non-union - a biomechanical solution with valgus sliding subtrochanteric osteotomy: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7513664/ https://www.ncbi.nlm.nih.gov/pubmed/32983389 http://dx.doi.org/10.5704/MOJ.2007.022 |
work_keys_str_mv | AT tehkh femoralnecknonunionabiomechanicalsolutionwithvalgusslidingsubtrochantericosteotomyacasereport AT rubenjk femoralnecknonunionabiomechanicalsolutionwithvalgusslidingsubtrochantericosteotomyacasereport AT chanck femoralnecknonunionabiomechanicalsolutionwithvalgusslidingsubtrochantericosteotomyacasereport AT abbasaa femoralnecknonunionabiomechanicalsolutionwithvalgusslidingsubtrochantericosteotomyacasereport |