Cargando…

Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy

The aim of this study was to develop an entropy-based structural health monitoring system for solving the problem of unstable entropy values observed when multiscale cross-sample entropy (MSCE) is employed to assess damage in real structures. Composite MSCE was utilized to enhance the reliability of...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Tzu-Kang, Chien, Yi-Hsiu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7514152/
https://www.ncbi.nlm.nih.gov/pubmed/33266757
http://dx.doi.org/10.3390/e21010041
_version_ 1783586522198441984
author Lin, Tzu-Kang
Chien, Yi-Hsiu
author_facet Lin, Tzu-Kang
Chien, Yi-Hsiu
author_sort Lin, Tzu-Kang
collection PubMed
description The aim of this study was to develop an entropy-based structural health monitoring system for solving the problem of unstable entropy values observed when multiscale cross-sample entropy (MSCE) is employed to assess damage in real structures. Composite MSCE was utilized to enhance the reliability of entropy values on every scale. Additionally, the first mode of a structure was extracted using ensemble empirical mode decomposition to conduct entropy analysis and evaluate the accuracy of damage assessment. A seven-story model was created to validate the efficiency of the proposed method and the damage index. Subsequently, an experiment was conducted on a seven-story steel benchmark structure including 15 damaged cases to compare the numerical and experimental models. A confusion matrix was applied to classify the results and evaluate the performance over three indices: accuracy, precision, and recall. The results revealed the feasibility of the modified structural health monitoring system and demonstrated its potential in the field of long-term monitoring.
format Online
Article
Text
id pubmed-7514152
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-75141522020-11-09 Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy Lin, Tzu-Kang Chien, Yi-Hsiu Entropy (Basel) Article The aim of this study was to develop an entropy-based structural health monitoring system for solving the problem of unstable entropy values observed when multiscale cross-sample entropy (MSCE) is employed to assess damage in real structures. Composite MSCE was utilized to enhance the reliability of entropy values on every scale. Additionally, the first mode of a structure was extracted using ensemble empirical mode decomposition to conduct entropy analysis and evaluate the accuracy of damage assessment. A seven-story model was created to validate the efficiency of the proposed method and the damage index. Subsequently, an experiment was conducted on a seven-story steel benchmark structure including 15 damaged cases to compare the numerical and experimental models. A confusion matrix was applied to classify the results and evaluate the performance over three indices: accuracy, precision, and recall. The results revealed the feasibility of the modified structural health monitoring system and demonstrated its potential in the field of long-term monitoring. MDPI 2019-01-09 /pmc/articles/PMC7514152/ /pubmed/33266757 http://dx.doi.org/10.3390/e21010041 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lin, Tzu-Kang
Chien, Yi-Hsiu
Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title_full Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title_fullStr Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title_full_unstemmed Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title_short Performance Evaluation of an Entropy-Based Structural Health Monitoring System Utilizing Composite Multiscale Cross-Sample Entropy
title_sort performance evaluation of an entropy-based structural health monitoring system utilizing composite multiscale cross-sample entropy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7514152/
https://www.ncbi.nlm.nih.gov/pubmed/33266757
http://dx.doi.org/10.3390/e21010041
work_keys_str_mv AT lintzukang performanceevaluationofanentropybasedstructuralhealthmonitoringsystemutilizingcompositemultiscalecrosssampleentropy
AT chienyihsiu performanceevaluationofanentropybasedstructuralhealthmonitoringsystemutilizingcompositemultiscalecrosssampleentropy