Cargando…
Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study
BACKGROUND: Low concentrations of morphine are required for safe dosing for intrathecal injections. Sometimes, manual dilution of morphine is performed to achieve these low concentrations, but risks dilution errors and bacterial contamination. The primary goal was to compare the concentrations of mo...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7517689/ https://www.ncbi.nlm.nih.gov/pubmed/32977744 http://dx.doi.org/10.1186/s12871-020-01151-2 |
_version_ | 1783587273900556288 |
---|---|
author | Teunissen, Aart Jan W. Koning, Mark V. Ruijgrok, Elisabeth J. Liefers, Willem J. de Bruijn, Bart Koopman, Seppe A. |
author_facet | Teunissen, Aart Jan W. Koning, Mark V. Ruijgrok, Elisabeth J. Liefers, Willem J. de Bruijn, Bart Koopman, Seppe A. |
author_sort | Teunissen, Aart Jan W. |
collection | PubMed |
description | BACKGROUND: Low concentrations of morphine are required for safe dosing for intrathecal injections. Sometimes, manual dilution of morphine is performed to achieve these low concentrations, but risks dilution errors and bacterial contamination. The primary goal was to compare the concentrations of morphine and bupivacaine between four groups of syringes. The secondary goal was to investigate the difference in contamination rate between these groups. METHODS: Twenty-five experienced anesthesia providers were asked to prepare a mixture of bupivacaine 2.0 mg/ml and morphine 60 μg/ml using 3 different methods as clean and precise as possible. The fourth method used was the aspiration of ampoules prepared by the pharmacy. The concentrations of morphine and bupivacaine were measured by High-Pressure Liquid Chromatography (HPLC). The medication was cultured for bacterial contamination. RESULTS: Group 1 (median 60 μg/ml; 95% CI: 59–110 μg/ml) yielded 3 outliers above 180 μg/ml morphine concentration. Group 2 (76 μg/ml; 95% CI: 72–80 μg/ml) and 3 (69 μg/ml; 95% CI: 66–71 μg/ml) were consistently higher than the target concentration of 60 μg. The group “pharmacy” was precise and accurate (59 μg/ml; 95% CI: 59–59 μg/ml). Group 2 and “pharmacy” had one contaminated sample with a spore-forming aerobic gram-positive rod. CONCLUSION: Manually diluted morphine is at risk for deviating concentrations, which could lead to increased side-effects. Medication produced by the hospital pharmacy was highly accurate. Furthermore, even when precautions are undertaken, contamination of the medication is a serious risk and appeared to be unrelated to the dilution process. |
format | Online Article Text |
id | pubmed-7517689 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-75176892020-09-25 Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study Teunissen, Aart Jan W. Koning, Mark V. Ruijgrok, Elisabeth J. Liefers, Willem J. de Bruijn, Bart Koopman, Seppe A. BMC Anesthesiol Research Article BACKGROUND: Low concentrations of morphine are required for safe dosing for intrathecal injections. Sometimes, manual dilution of morphine is performed to achieve these low concentrations, but risks dilution errors and bacterial contamination. The primary goal was to compare the concentrations of morphine and bupivacaine between four groups of syringes. The secondary goal was to investigate the difference in contamination rate between these groups. METHODS: Twenty-five experienced anesthesia providers were asked to prepare a mixture of bupivacaine 2.0 mg/ml and morphine 60 μg/ml using 3 different methods as clean and precise as possible. The fourth method used was the aspiration of ampoules prepared by the pharmacy. The concentrations of morphine and bupivacaine were measured by High-Pressure Liquid Chromatography (HPLC). The medication was cultured for bacterial contamination. RESULTS: Group 1 (median 60 μg/ml; 95% CI: 59–110 μg/ml) yielded 3 outliers above 180 μg/ml morphine concentration. Group 2 (76 μg/ml; 95% CI: 72–80 μg/ml) and 3 (69 μg/ml; 95% CI: 66–71 μg/ml) were consistently higher than the target concentration of 60 μg. The group “pharmacy” was precise and accurate (59 μg/ml; 95% CI: 59–59 μg/ml). Group 2 and “pharmacy” had one contaminated sample with a spore-forming aerobic gram-positive rod. CONCLUSION: Manually diluted morphine is at risk for deviating concentrations, which could lead to increased side-effects. Medication produced by the hospital pharmacy was highly accurate. Furthermore, even when precautions are undertaken, contamination of the medication is a serious risk and appeared to be unrelated to the dilution process. BioMed Central 2020-09-25 /pmc/articles/PMC7517689/ /pubmed/32977744 http://dx.doi.org/10.1186/s12871-020-01151-2 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Teunissen, Aart Jan W. Koning, Mark V. Ruijgrok, Elisabeth J. Liefers, Willem J. de Bruijn, Bart Koopman, Seppe A. Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title | Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title_full | Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title_fullStr | Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title_full_unstemmed | Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title_short | Measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
title_sort | measurement of drug concentration and bacterial contamination after diluting morphine for intrathecal administration: an experimental study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7517689/ https://www.ncbi.nlm.nih.gov/pubmed/32977744 http://dx.doi.org/10.1186/s12871-020-01151-2 |
work_keys_str_mv | AT teunissenaartjanw measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy AT koningmarkv measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy AT ruijgrokelisabethj measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy AT lieferswillemj measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy AT debruijnbart measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy AT koopmanseppea measurementofdrugconcentrationandbacterialcontaminationafterdilutingmorphineforintrathecaladministrationanexperimentalstudy |