Cargando…
Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report
BACKGROUND: An ascending aortic pseudoaneurysm is a severe and rare complication following cardiothoracic surgery. This case report demonstrates its possible misinterpretation and the consequent importance of multidisciplinary evaluation. CASE PRESENTATION: We present a case of an 18-year-old Caucas...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7517812/ https://www.ncbi.nlm.nih.gov/pubmed/32972458 http://dx.doi.org/10.1186/s13256-020-02465-y |
_version_ | 1783587299712303104 |
---|---|
author | Chiocchi, Marcello Spiritigliozzi, Luigi Di Tosto, Federica Benelli, Leonardo D’Errico, Francesca Presicce, Matteo Pugliese, Luca Ricci, Francesca De Stasio, Vincenzo Di Donna, Carlo Pasqualetto, Monia Colella, Dionisio Ferdinando Floris, Roberto |
author_facet | Chiocchi, Marcello Spiritigliozzi, Luigi Di Tosto, Federica Benelli, Leonardo D’Errico, Francesca Presicce, Matteo Pugliese, Luca Ricci, Francesca De Stasio, Vincenzo Di Donna, Carlo Pasqualetto, Monia Colella, Dionisio Ferdinando Floris, Roberto |
author_sort | Chiocchi, Marcello |
collection | PubMed |
description | BACKGROUND: An ascending aortic pseudoaneurysm is a severe and rare complication following cardiothoracic surgery. This case report demonstrates its possible misinterpretation and the consequent importance of multidisciplinary evaluation. CASE PRESENTATION: We present a case of an 18-year-old Caucasian man with Marfan syndrome who developed an ascending aortic pseudoaneurysm about 1 year after undergoing cardiac surgery with the Bentall procedure. Computed tomographic examination of the thoracic aorta and positron emission tomography–computed tomography initially suggested a lymphomatous pathology. However, these imaging results were in contrast to the transesophageal echocardiogram and the laboratory data that showed negative results for hematological pathology. A second computed tomographic scan redirected the diagnosis toward a pseudoaneurysm. CONCLUSION: This case demonstrates the utility of close communication and interdisciplinary consultation between cardiovascular radiologists and the cardiac surgery team, which are mandatory in order to maximize their diagnostic skills in identifying postoperative complications. |
format | Online Article Text |
id | pubmed-7517812 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-75178122020-09-29 Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report Chiocchi, Marcello Spiritigliozzi, Luigi Di Tosto, Federica Benelli, Leonardo D’Errico, Francesca Presicce, Matteo Pugliese, Luca Ricci, Francesca De Stasio, Vincenzo Di Donna, Carlo Pasqualetto, Monia Colella, Dionisio Ferdinando Floris, Roberto J Med Case Rep Case Report BACKGROUND: An ascending aortic pseudoaneurysm is a severe and rare complication following cardiothoracic surgery. This case report demonstrates its possible misinterpretation and the consequent importance of multidisciplinary evaluation. CASE PRESENTATION: We present a case of an 18-year-old Caucasian man with Marfan syndrome who developed an ascending aortic pseudoaneurysm about 1 year after undergoing cardiac surgery with the Bentall procedure. Computed tomographic examination of the thoracic aorta and positron emission tomography–computed tomography initially suggested a lymphomatous pathology. However, these imaging results were in contrast to the transesophageal echocardiogram and the laboratory data that showed negative results for hematological pathology. A second computed tomographic scan redirected the diagnosis toward a pseudoaneurysm. CONCLUSION: This case demonstrates the utility of close communication and interdisciplinary consultation between cardiovascular radiologists and the cardiac surgery team, which are mandatory in order to maximize their diagnostic skills in identifying postoperative complications. BioMed Central 2020-09-25 /pmc/articles/PMC7517812/ /pubmed/32972458 http://dx.doi.org/10.1186/s13256-020-02465-y Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Case Report Chiocchi, Marcello Spiritigliozzi, Luigi Di Tosto, Federica Benelli, Leonardo D’Errico, Francesca Presicce, Matteo Pugliese, Luca Ricci, Francesca De Stasio, Vincenzo Di Donna, Carlo Pasqualetto, Monia Colella, Dionisio Ferdinando Floris, Roberto Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title | Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title_full | Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title_fullStr | Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title_full_unstemmed | Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title_short | Ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
title_sort | ascending aorta pseudoaneurysm simulating mediastinal lymphoma in computed tomography, a possible diagnostic error: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7517812/ https://www.ncbi.nlm.nih.gov/pubmed/32972458 http://dx.doi.org/10.1186/s13256-020-02465-y |
work_keys_str_mv | AT chiocchimarcello ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT spiritigliozziluigi ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT ditostofederica ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT benellileonardo ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT derricofrancesca ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT presiccematteo ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT puglieseluca ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT riccifrancesca ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT destasiovincenzo ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT didonnacarlo ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT pasqualettomonia ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT colelladionisioferdinando ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport AT florisroberto ascendingaortapseudoaneurysmsimulatingmediastinallymphomaincomputedtomographyapossiblediagnosticerroracasereport |