Cargando…

Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries

INTRODUCTION: Securing a difficult airway during maxillofacial surgeries is a great challenge for anesthetists, and the flexible fiber-optic bronchoscope is the gold standard while managing such cases. While passing the flexible bronchoscope by the nasal route, the success rate is higher as compared...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Lohith, Abbas, Haider, Kothari, Nikhil, Kohli, Monica, Dhasmana, Satish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7518489/
https://www.ncbi.nlm.nih.gov/pubmed/33041575
http://dx.doi.org/10.4103/njms.NJMS_71_17
_version_ 1783587406707949568
author Kumar, Lohith
Abbas, Haider
Kothari, Nikhil
Kohli, Monica
Dhasmana, Satish
author_facet Kumar, Lohith
Abbas, Haider
Kothari, Nikhil
Kohli, Monica
Dhasmana, Satish
author_sort Kumar, Lohith
collection PubMed
description INTRODUCTION: Securing a difficult airway during maxillofacial surgeries is a great challenge for anesthetists, and the flexible fiber-optic bronchoscope is the gold standard while managing such cases. While passing the flexible bronchoscope by the nasal route, the success rate is higher as compared with oral approach as the nasopharynx is in line with the larynx and prevents acute angulation in the oropharynx. MATERIALS AND METHODS: A randomized control trial was planned in 73 patients out of whom sixty patients gave consent for the procedure. The patients we randomly divided into two groups (n = 30) with application of 4% nebulized lignocaine in one group and the use of 2% nebulized lignocaine in the other group, and the patient's comfort was noted using five-point Puchner scale. RESULTS: The mean value of patient comfort Puchner scale of Group A was 1.30 ± 0.08 and of Group B was 2.23 ± 0.12. The mean value of Puchner scale of Group B was significantly higher (41.8%) as compared to Group A (t = 6.208; df = 51; P < 0.0001). The secondary outcome measures were optimal intubating conditions and hemodynamic changes during awake fiber-optic nasotracheal intubation. The procedural time of two groups when compared showed that the mean procedural time of Group A was shorter (29.67 ± 5.40 min) than the time consumed in Group B (34.93 ± 5.52 min). CONCLUSION: Four percent nebulized lidocaine provided adequate airway anesthesia and optimal intubating conditions along with stable hemodynamics for awake fiber-optic intubation as compared to 2% nebulized lidocaine.
format Online
Article
Text
id pubmed-7518489
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75184892020-10-09 Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries Kumar, Lohith Abbas, Haider Kothari, Nikhil Kohli, Monica Dhasmana, Satish Natl J Maxillofac Surg Original Article INTRODUCTION: Securing a difficult airway during maxillofacial surgeries is a great challenge for anesthetists, and the flexible fiber-optic bronchoscope is the gold standard while managing such cases. While passing the flexible bronchoscope by the nasal route, the success rate is higher as compared with oral approach as the nasopharynx is in line with the larynx and prevents acute angulation in the oropharynx. MATERIALS AND METHODS: A randomized control trial was planned in 73 patients out of whom sixty patients gave consent for the procedure. The patients we randomly divided into two groups (n = 30) with application of 4% nebulized lignocaine in one group and the use of 2% nebulized lignocaine in the other group, and the patient's comfort was noted using five-point Puchner scale. RESULTS: The mean value of patient comfort Puchner scale of Group A was 1.30 ± 0.08 and of Group B was 2.23 ± 0.12. The mean value of Puchner scale of Group B was significantly higher (41.8%) as compared to Group A (t = 6.208; df = 51; P < 0.0001). The secondary outcome measures were optimal intubating conditions and hemodynamic changes during awake fiber-optic nasotracheal intubation. The procedural time of two groups when compared showed that the mean procedural time of Group A was shorter (29.67 ± 5.40 min) than the time consumed in Group B (34.93 ± 5.52 min). CONCLUSION: Four percent nebulized lidocaine provided adequate airway anesthesia and optimal intubating conditions along with stable hemodynamics for awake fiber-optic intubation as compared to 2% nebulized lidocaine. Wolters Kluwer - Medknow 2020 2020-06-18 /pmc/articles/PMC7518489/ /pubmed/33041575 http://dx.doi.org/10.4103/njms.NJMS_71_17 Text en Copyright: © 2020 National Journal of Maxillofacial Surgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumar, Lohith
Abbas, Haider
Kothari, Nikhil
Kohli, Monica
Dhasmana, Satish
Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title_full Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title_fullStr Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title_full_unstemmed Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title_short Effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
title_sort effect of 4% nebulized lignocaine versus 2% nebulized lignocaine for awake fibroscopic nasotracheal intubation in maxillofacial surgeries
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7518489/
https://www.ncbi.nlm.nih.gov/pubmed/33041575
http://dx.doi.org/10.4103/njms.NJMS_71_17
work_keys_str_mv AT kumarlohith effectof4nebulizedlignocaineversus2nebulizedlignocaineforawakefibroscopicnasotrachealintubationinmaxillofacialsurgeries
AT abbashaider effectof4nebulizedlignocaineversus2nebulizedlignocaineforawakefibroscopicnasotrachealintubationinmaxillofacialsurgeries
AT kotharinikhil effectof4nebulizedlignocaineversus2nebulizedlignocaineforawakefibroscopicnasotrachealintubationinmaxillofacialsurgeries
AT kohlimonica effectof4nebulizedlignocaineversus2nebulizedlignocaineforawakefibroscopicnasotrachealintubationinmaxillofacialsurgeries
AT dhasmanasatish effectof4nebulizedlignocaineversus2nebulizedlignocaineforawakefibroscopicnasotrachealintubationinmaxillofacialsurgeries