Cargando…
A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement
BACKGROUND: The tibial slope plays an important role in knee surgery. However, standard radiographic measurement techniques have a low reproducibility and do not allow differentiation between medial and lateral articular surfaces. Despite availability of three-dimensional imaging, so far, no real 3D...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7520019/ https://www.ncbi.nlm.nih.gov/pubmed/32979919 http://dx.doi.org/10.1186/s12891-020-03657-9 |
_version_ | 1783587693618266112 |
---|---|
author | Hoch, Armando Jud, Lukas Roth, Tabitha Vlachopoulos, Lazaros Fürnstahl, Philipp Fucentese, Sandro F. |
author_facet | Hoch, Armando Jud, Lukas Roth, Tabitha Vlachopoulos, Lazaros Fürnstahl, Philipp Fucentese, Sandro F. |
author_sort | Hoch, Armando |
collection | PubMed |
description | BACKGROUND: The tibial slope plays an important role in knee surgery. However, standard radiographic measurement techniques have a low reproducibility and do not allow differentiation between medial and lateral articular surfaces. Despite availability of three-dimensional imaging, so far, no real 3D measurement technique was introduced and compared to radiographic measurement, which were the purposes of this study. METHODS: Computed tomography scans of 54 knees in 51 patients (41 males and 10 females) with a mean age of 46 years (range 22–67 years) were included. A novel 3D measurement technique was applied by two readers to measure the tibial slope of medial and lateral tibial plateau and rim. A statistical analysis was conducted to determine the intraclass correlation coefficient (ICC) for the new technique and compare it to a standard radiographic measurement. RESULTS: The mean 3D tibial slope for the medial plateau and rim was 7.4° and 7.6°, for the lateral plateau and rim 7.5° and 8.1°, respectively. The mean radiographic slope was 6.0°. Statistical analysis showed an ICC between both readers of 0.909, 0.987, 0.918, 0.893, for the 3D measurement of medial plateau, medial rim, lateral plateau and lateral rim, respectively, whereas the radiographic technique showed an ICC of 0.733. CONCLUSIONS: The proposed novel measurement technique shows a high intraclass agreement and offers an applicable opportunity to assess the tibial slope three-dimensionally. Furthermore, the medial and lateral articular surfaces can be measured separately and one can differentiate the slope from the plateau and from the rim. As three-dimensional planning becomes successively more important, our measurement technique might deliver a useful supplement to the standard radiographic assessment in slope related knee surgery. LEVEL OF EVIDENCE: Level III, diagnostic study. |
format | Online Article Text |
id | pubmed-7520019 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-75200192020-09-29 A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement Hoch, Armando Jud, Lukas Roth, Tabitha Vlachopoulos, Lazaros Fürnstahl, Philipp Fucentese, Sandro F. BMC Musculoskelet Disord Research Article BACKGROUND: The tibial slope plays an important role in knee surgery. However, standard radiographic measurement techniques have a low reproducibility and do not allow differentiation between medial and lateral articular surfaces. Despite availability of three-dimensional imaging, so far, no real 3D measurement technique was introduced and compared to radiographic measurement, which were the purposes of this study. METHODS: Computed tomography scans of 54 knees in 51 patients (41 males and 10 females) with a mean age of 46 years (range 22–67 years) were included. A novel 3D measurement technique was applied by two readers to measure the tibial slope of medial and lateral tibial plateau and rim. A statistical analysis was conducted to determine the intraclass correlation coefficient (ICC) for the new technique and compare it to a standard radiographic measurement. RESULTS: The mean 3D tibial slope for the medial plateau and rim was 7.4° and 7.6°, for the lateral plateau and rim 7.5° and 8.1°, respectively. The mean radiographic slope was 6.0°. Statistical analysis showed an ICC between both readers of 0.909, 0.987, 0.918, 0.893, for the 3D measurement of medial plateau, medial rim, lateral plateau and lateral rim, respectively, whereas the radiographic technique showed an ICC of 0.733. CONCLUSIONS: The proposed novel measurement technique shows a high intraclass agreement and offers an applicable opportunity to assess the tibial slope three-dimensionally. Furthermore, the medial and lateral articular surfaces can be measured separately and one can differentiate the slope from the plateau and from the rim. As three-dimensional planning becomes successively more important, our measurement technique might deliver a useful supplement to the standard radiographic assessment in slope related knee surgery. LEVEL OF EVIDENCE: Level III, diagnostic study. BioMed Central 2020-09-26 /pmc/articles/PMC7520019/ /pubmed/32979919 http://dx.doi.org/10.1186/s12891-020-03657-9 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Hoch, Armando Jud, Lukas Roth, Tabitha Vlachopoulos, Lazaros Fürnstahl, Philipp Fucentese, Sandro F. A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title | A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title_full | A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title_fullStr | A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title_full_unstemmed | A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title_short | A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
title_sort | real 3d measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7520019/ https://www.ncbi.nlm.nih.gov/pubmed/32979919 http://dx.doi.org/10.1186/s12891-020-03657-9 |
work_keys_str_mv | AT hocharmando areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT judlukas areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT rothtabitha areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT vlachopouloslazaros areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT furnstahlphilipp areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT fucentesesandrof areal3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT hocharmando real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT judlukas real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT rothtabitha real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT vlachopouloslazaros real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT furnstahlphilipp real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement AT fucentesesandrof real3dmeasurementtechniqueforthetibialslopedifferentiationbetweendifferentarticularsurfacesandcomparisontoradiographicslopemeasurement |