Cargando…

Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature

MATERIALS AND METHODS: Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel a...

Descripción completa

Detalles Bibliográficos
Autores principales: Abuhulaibah, Hind F., AbuMostafa, Ammar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7520684/
https://www.ncbi.nlm.nih.gov/pubmed/33014060
http://dx.doi.org/10.1155/2020/8830163
_version_ 1783587825772396544
author Abuhulaibah, Hind F.
AbuMostafa, Ammar
author_facet Abuhulaibah, Hind F.
AbuMostafa, Ammar
author_sort Abuhulaibah, Hind F.
collection PubMed
description MATERIALS AND METHODS: Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel artificial canal in a water bath at 37°C simulating body temperature. The procedure was video recorded, and the number of cycles to fracture (NCF) was calculated by multiplying the time taken to fracture, with the number of rotations per second. The data were analyzed for normality, and thereafter, one-way ANOVA with multiple Bonferroni was used as the post hoc test. RESULTS: The resistance to CF of OC files was significantly higher than PTG files in all groups. In groups immersed in NaOCl for one minute, OC files showed significant drop in the CF resistance; PTG files showed a drop as well but not significantly. Both files demonstrated a significant drop in resistance to CF after immersion in NaOCl for five minutes compared to the control group. CONCLUSION: OC files were significantly more resistant to CF compared to PTG in all groups. Immersion in 2.5% NaOCl for 5 minutes significantly reduced the resistance to CF for all the files.
format Online
Article
Text
id pubmed-7520684
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-75206842020-10-02 Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature Abuhulaibah, Hind F. AbuMostafa, Ammar Int J Dent Research Article MATERIALS AND METHODS: Forty-five files from each brand were randomly assigned to three groups (n = 15) and subjected to the following: no immersion (control), 1-minute immersion, and 5-minute immersion in 2.5% NaOCl at 37°C. CF for all the files was tested within a well-lubricated stainless-steel artificial canal in a water bath at 37°C simulating body temperature. The procedure was video recorded, and the number of cycles to fracture (NCF) was calculated by multiplying the time taken to fracture, with the number of rotations per second. The data were analyzed for normality, and thereafter, one-way ANOVA with multiple Bonferroni was used as the post hoc test. RESULTS: The resistance to CF of OC files was significantly higher than PTG files in all groups. In groups immersed in NaOCl for one minute, OC files showed significant drop in the CF resistance; PTG files showed a drop as well but not significantly. Both files demonstrated a significant drop in resistance to CF after immersion in NaOCl for five minutes compared to the control group. CONCLUSION: OC files were significantly more resistant to CF compared to PTG in all groups. Immersion in 2.5% NaOCl for 5 minutes significantly reduced the resistance to CF for all the files. Hindawi 2020-09-19 /pmc/articles/PMC7520684/ /pubmed/33014060 http://dx.doi.org/10.1155/2020/8830163 Text en Copyright © 2020 Hind F. Abuhulaibah and Ammar AbuMostafa. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Abuhulaibah, Hind F.
AbuMostafa, Ammar
Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title_full Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title_fullStr Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title_full_unstemmed Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title_short Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature
title_sort resistance to cyclic fatigue of nickel-titanium files immersed in sodium hypochlorite at body temperature
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7520684/
https://www.ncbi.nlm.nih.gov/pubmed/33014060
http://dx.doi.org/10.1155/2020/8830163
work_keys_str_mv AT abuhulaibahhindf resistancetocyclicfatigueofnickeltitaniumfilesimmersedinsodiumhypochloriteatbodytemperature
AT abumostafaammar resistancetocyclicfatigueofnickeltitaniumfilesimmersedinsodiumhypochloriteatbodytemperature