Cargando…
Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation
BACKGROUND: In our clinic, a substantial number of patients present with transtibial residual limb pain of no specific somatic origin. Silicone liner induced tissue compression may reduce blood flow, possibly causing residual limb pain. Thus, as a first step we investigated if the liner itself has a...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7521692/ https://www.ncbi.nlm.nih.gov/pubmed/32986780 http://dx.doi.org/10.1371/journal.pone.0239930 |
_version_ | 1783588024209113088 |
---|---|
author | Berli, Martin C. Jundt-Ecker, Michèle Meier, Margrit R. Hofer, Michael Schöni, Madlaina Götschi, Tobias Uçkay, Ilker Böni, Thomas Waibel, Felix W. A. |
author_facet | Berli, Martin C. Jundt-Ecker, Michèle Meier, Margrit R. Hofer, Michael Schöni, Madlaina Götschi, Tobias Uçkay, Ilker Böni, Thomas Waibel, Felix W. A. |
author_sort | Berli, Martin C. |
collection | PubMed |
description | BACKGROUND: In our clinic, a substantial number of patients present with transtibial residual limb pain of no specific somatic origin. Silicone liner induced tissue compression may reduce blood flow, possibly causing residual limb pain. Thus, as a first step we investigated if the liner itself has an effect on transcutaneous oxygen pressure (TcPO2). METHODS: Persons with unilateral transtibial amputation and residual limb pain of unknown origin were included. Medical history, including residual limb pain, was recorded, and the SF-36 administered. Resting TcPO2 levels were measured in the supine position and without a liner at 0, 10, 20 and 30 minutes using two sensors: one placed in the Transverse plane over the tip of the Tibia End (= TTE), the other placed in the Sagittal plane, distally over the Peroneal Compartment (= SPC). Measurements were repeated with specially prepared liners avoiding additional pressure due to sensor placement. Statistical analyses were performed using SPSS. RESULTS: Twenty persons (9 women, 11 men) with a mean age of 68.65 years (range 47–86 years) participated. The transtibial amputation occurred on average 43 months prior to study entry (range 3–119 months). With liner wear, both sensors measured TcPO2 levels that were significantly lower than those measured without a liner (TTE: p < 0.001; SPC: p = 0.002) after 10, 20 and 30 minutes. No significant differences were found between TcPO2 levels over time between the sensors. There were no significant associations between TcPO2 levels and pain, smoking status, age, duration of daily liner use, mobility level, and revision history. CONCLUSION: Resting TcPO2 levels decreased significantly while wearing a liner alone, without a prosthetic socket. Further studies are required to investigate the effect of liner wear on exercise TcPO2 levels. |
format | Online Article Text |
id | pubmed-7521692 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-75216922020-10-06 Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation Berli, Martin C. Jundt-Ecker, Michèle Meier, Margrit R. Hofer, Michael Schöni, Madlaina Götschi, Tobias Uçkay, Ilker Böni, Thomas Waibel, Felix W. A. PLoS One Research Article BACKGROUND: In our clinic, a substantial number of patients present with transtibial residual limb pain of no specific somatic origin. Silicone liner induced tissue compression may reduce blood flow, possibly causing residual limb pain. Thus, as a first step we investigated if the liner itself has an effect on transcutaneous oxygen pressure (TcPO2). METHODS: Persons with unilateral transtibial amputation and residual limb pain of unknown origin were included. Medical history, including residual limb pain, was recorded, and the SF-36 administered. Resting TcPO2 levels were measured in the supine position and without a liner at 0, 10, 20 and 30 minutes using two sensors: one placed in the Transverse plane over the tip of the Tibia End (= TTE), the other placed in the Sagittal plane, distally over the Peroneal Compartment (= SPC). Measurements were repeated with specially prepared liners avoiding additional pressure due to sensor placement. Statistical analyses were performed using SPSS. RESULTS: Twenty persons (9 women, 11 men) with a mean age of 68.65 years (range 47–86 years) participated. The transtibial amputation occurred on average 43 months prior to study entry (range 3–119 months). With liner wear, both sensors measured TcPO2 levels that were significantly lower than those measured without a liner (TTE: p < 0.001; SPC: p = 0.002) after 10, 20 and 30 minutes. No significant differences were found between TcPO2 levels over time between the sensors. There were no significant associations between TcPO2 levels and pain, smoking status, age, duration of daily liner use, mobility level, and revision history. CONCLUSION: Resting TcPO2 levels decreased significantly while wearing a liner alone, without a prosthetic socket. Further studies are required to investigate the effect of liner wear on exercise TcPO2 levels. Public Library of Science 2020-09-28 /pmc/articles/PMC7521692/ /pubmed/32986780 http://dx.doi.org/10.1371/journal.pone.0239930 Text en © 2020 Berli et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Berli, Martin C. Jundt-Ecker, Michèle Meier, Margrit R. Hofer, Michael Schöni, Madlaina Götschi, Tobias Uçkay, Ilker Böni, Thomas Waibel, Felix W. A. Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title | Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title_full | Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title_fullStr | Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title_full_unstemmed | Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title_short | Resting TcPO2 levels decrease during liner wear in persons with a transtibial amputation |
title_sort | resting tcpo2 levels decrease during liner wear in persons with a transtibial amputation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7521692/ https://www.ncbi.nlm.nih.gov/pubmed/32986780 http://dx.doi.org/10.1371/journal.pone.0239930 |
work_keys_str_mv | AT berlimartinc restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT jundteckermichele restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT meiermargritr restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT hofermichael restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT schonimadlaina restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT gotschitobias restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT uckayilker restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT bonithomas restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation AT waibelfelixwa restingtcpo2levelsdecreaseduringlinerwearinpersonswithatranstibialamputation |