Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas
Myopia is one of the main risk factors for the onset of open-angle glaucoma. One of the first steps to assess glaucoma occurrence is the measurement of the intraocular pressure (IOP) by the Goldmann applanation tonometry (GAT). Even if this device is considered to be the gold standard for such measu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7522400/ https://www.ncbi.nlm.nih.gov/pubmed/33061262 http://dx.doi.org/10.2147/OPTH.S263856 |
_version_ | 1783588172432670720 |
---|---|
author | De Bernardo, Maddalena Cembalo, Giovanni Rosa, Nicola |
author_facet | De Bernardo, Maddalena Cembalo, Giovanni Rosa, Nicola |
author_sort | De Bernardo, Maddalena |
collection | PubMed |
description | Myopia is one of the main risk factors for the onset of open-angle glaucoma. One of the first steps to assess glaucoma occurrence is the measurement of the intraocular pressure (IOP) by the Goldmann applanation tonometry (GAT). Even if this device is considered to be the gold standard for such measurements, it is affected by several sources of errors. Among these, there are the corneal thickness and curvature, both modified by corneal refractive surgery (CRS), that nowadays has become a very popular method to treat refractive errors. Indeed, CRS, by modifying the corneal shape and structure, causes an underestimation of the IOP measurements. In the literature, several IOP correction formulas to utilize with different devices have been proposed to overcome this problem. This paper aims to review the various correction formulas applied to the GAT in the attempt to improve the reliability of this measurement. |
format | Online Article Text |
id | pubmed-7522400 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-75224002020-10-14 Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas De Bernardo, Maddalena Cembalo, Giovanni Rosa, Nicola Clin Ophthalmol Review Myopia is one of the main risk factors for the onset of open-angle glaucoma. One of the first steps to assess glaucoma occurrence is the measurement of the intraocular pressure (IOP) by the Goldmann applanation tonometry (GAT). Even if this device is considered to be the gold standard for such measurements, it is affected by several sources of errors. Among these, there are the corneal thickness and curvature, both modified by corneal refractive surgery (CRS), that nowadays has become a very popular method to treat refractive errors. Indeed, CRS, by modifying the corneal shape and structure, causes an underestimation of the IOP measurements. In the literature, several IOP correction formulas to utilize with different devices have been proposed to overcome this problem. This paper aims to review the various correction formulas applied to the GAT in the attempt to improve the reliability of this measurement. Dove 2020-09-24 /pmc/articles/PMC7522400/ /pubmed/33061262 http://dx.doi.org/10.2147/OPTH.S263856 Text en © 2020 De Bernardo et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Review De Bernardo, Maddalena Cembalo, Giovanni Rosa, Nicola Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title | Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title_full | Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title_fullStr | Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title_full_unstemmed | Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title_short | Reliability of Intraocular Pressure Measurement by Goldmann Applanation Tonometry After Refractive Surgery: A Review of Different Correction Formulas |
title_sort | reliability of intraocular pressure measurement by goldmann applanation tonometry after refractive surgery: a review of different correction formulas |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7522400/ https://www.ncbi.nlm.nih.gov/pubmed/33061262 http://dx.doi.org/10.2147/OPTH.S263856 |
work_keys_str_mv | AT debernardomaddalena reliabilityofintraocularpressuremeasurementbygoldmannapplanationtonometryafterrefractivesurgeryareviewofdifferentcorrectionformulas AT cembalogiovanni reliabilityofintraocularpressuremeasurementbygoldmannapplanationtonometryafterrefractivesurgeryareviewofdifferentcorrectionformulas AT rosanicola reliabilityofintraocularpressuremeasurementbygoldmannapplanationtonometryafterrefractivesurgeryareviewofdifferentcorrectionformulas |