Cargando…

Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening

BACKGROUND: The introduction of high-risk human papillomavirus (hrHPV) testing as part of primary cervical screening is anticipated to improve sensitivity, but also the number of women who will screen positive. Reflex cytology is the preferred triage test in most settings but has limitations includi...

Descripción completa

Detalles Bibliográficos
Autores principales: Paraskevaidi, Maria, Cameron, Simon J.S., Whelan, Eilbhe, Bowden, Sarah, Tzafetas, Menelaos, Mitra, Anita, Semertzidou, Anita, Athanasiou, Antonis, Bennett, Phillip R., MacIntyre, David A., Takats, Zoltan, Kyrgiou, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7522750/
https://www.ncbi.nlm.nih.gov/pubmed/32980699
http://dx.doi.org/10.1016/j.ebiom.2020.103017
_version_ 1783588252110815232
author Paraskevaidi, Maria
Cameron, Simon J.S.
Whelan, Eilbhe
Bowden, Sarah
Tzafetas, Menelaos
Mitra, Anita
Semertzidou, Anita
Athanasiou, Antonis
Bennett, Phillip R.
MacIntyre, David A.
Takats, Zoltan
Kyrgiou, Maria
author_facet Paraskevaidi, Maria
Cameron, Simon J.S.
Whelan, Eilbhe
Bowden, Sarah
Tzafetas, Menelaos
Mitra, Anita
Semertzidou, Anita
Athanasiou, Antonis
Bennett, Phillip R.
MacIntyre, David A.
Takats, Zoltan
Kyrgiou, Maria
author_sort Paraskevaidi, Maria
collection PubMed
description BACKGROUND: The introduction of high-risk human papillomavirus (hrHPV) testing as part of primary cervical screening is anticipated to improve sensitivity, but also the number of women who will screen positive. Reflex cytology is the preferred triage test in most settings but has limitations including moderate diagnostic accuracy, lack of automation, inter-observer variability and the need for clinician-collected sample. Novel, objective and cost-effective approaches are needed. METHODS: In this study, we assessed the potential use of an automated metabolomic robotic platform, employing the principle of laser-assisted Rapid Evaporative Ionisation Mass Spectrometry (LA-REIMS) in cervical cancer screening. FINDINGS: In a population of 130 women, LA-REIMS achieved 94% sensitivity and 83% specificity (AUC: 91.6%) in distinguishing women testing positive (n = 65) or negative (n = 65) for hrHPV. We performed further analysis according to disease severity with LA-REIMS achieving sensitivity and specificity of 91% and 73% respectively (AUC: 86.7%) in discriminating normal from high-grade pre-invasive disease. INTERPRETATION: This automated high-throughput technology holds promise as a low-cost and rapid test for cervical cancer screening and triage. The use of platforms like LA-REIMS has the potential to further improve the accuracy and efficiency of the current national screening programme. FUNDING: Work was funded by the MRC Imperial Confidence in Concept Scheme, Imperial College Healthcare Charity, British Society for Colposcopy and Cervical Pathology, National Research Development and Innovation Office of Hungary, Waters corporation and NIHR BRC.
format Online
Article
Text
id pubmed-7522750
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-75227502020-10-02 Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening Paraskevaidi, Maria Cameron, Simon J.S. Whelan, Eilbhe Bowden, Sarah Tzafetas, Menelaos Mitra, Anita Semertzidou, Anita Athanasiou, Antonis Bennett, Phillip R. MacIntyre, David A. Takats, Zoltan Kyrgiou, Maria EBioMedicine Research Paper BACKGROUND: The introduction of high-risk human papillomavirus (hrHPV) testing as part of primary cervical screening is anticipated to improve sensitivity, but also the number of women who will screen positive. Reflex cytology is the preferred triage test in most settings but has limitations including moderate diagnostic accuracy, lack of automation, inter-observer variability and the need for clinician-collected sample. Novel, objective and cost-effective approaches are needed. METHODS: In this study, we assessed the potential use of an automated metabolomic robotic platform, employing the principle of laser-assisted Rapid Evaporative Ionisation Mass Spectrometry (LA-REIMS) in cervical cancer screening. FINDINGS: In a population of 130 women, LA-REIMS achieved 94% sensitivity and 83% specificity (AUC: 91.6%) in distinguishing women testing positive (n = 65) or negative (n = 65) for hrHPV. We performed further analysis according to disease severity with LA-REIMS achieving sensitivity and specificity of 91% and 73% respectively (AUC: 86.7%) in discriminating normal from high-grade pre-invasive disease. INTERPRETATION: This automated high-throughput technology holds promise as a low-cost and rapid test for cervical cancer screening and triage. The use of platforms like LA-REIMS has the potential to further improve the accuracy and efficiency of the current national screening programme. FUNDING: Work was funded by the MRC Imperial Confidence in Concept Scheme, Imperial College Healthcare Charity, British Society for Colposcopy and Cervical Pathology, National Research Development and Innovation Office of Hungary, Waters corporation and NIHR BRC. Elsevier 2020-09-25 /pmc/articles/PMC7522750/ /pubmed/32980699 http://dx.doi.org/10.1016/j.ebiom.2020.103017 Text en © 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Paper
Paraskevaidi, Maria
Cameron, Simon J.S.
Whelan, Eilbhe
Bowden, Sarah
Tzafetas, Menelaos
Mitra, Anita
Semertzidou, Anita
Athanasiou, Antonis
Bennett, Phillip R.
MacIntyre, David A.
Takats, Zoltan
Kyrgiou, Maria
Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title_full Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title_fullStr Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title_full_unstemmed Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title_short Laser-assisted rapid evaporative ionisation mass spectrometry (LA-REIMS) as a metabolomics platform in cervical cancer screening
title_sort laser-assisted rapid evaporative ionisation mass spectrometry (la-reims) as a metabolomics platform in cervical cancer screening
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7522750/
https://www.ncbi.nlm.nih.gov/pubmed/32980699
http://dx.doi.org/10.1016/j.ebiom.2020.103017
work_keys_str_mv AT paraskevaidimaria laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT cameronsimonjs laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT whelaneilbhe laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT bowdensarah laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT tzafetasmenelaos laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT mitraanita laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT semertzidouanita laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT athanasiouantonis laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT bennettphillipr laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT macintyredavida laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT takatszoltan laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening
AT kyrgioumaria laserassistedrapidevaporativeionisationmassspectrometrylareimsasametabolomicsplatformincervicalcancerscreening