The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy
BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7523573/ https://www.ncbi.nlm.nih.gov/pubmed/32282445 http://dx.doi.org/10.1097/LBR.0000000000000669 |
_version_ | 1783588404239269888 |
---|---|
author | Horinouchi, Hirohisa Asano, Fumihiro Okubo, Kenichi Okada, Yoshinori Ohsaki, Yoshinobu Komase, Yuko Hashizume, Toshinori Kohno, Mitsutomo Aoe, Motoi |
author_facet | Horinouchi, Hirohisa Asano, Fumihiro Okubo, Kenichi Okada, Yoshinori Ohsaki, Yoshinobu Komase, Yuko Hashizume, Toshinori Kohno, Mitsutomo Aoe, Motoi |
author_sort | Horinouchi, Hirohisa |
collection | PubMed |
description | BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The survey form was mailed to 532 facilities accredited by the society. The numbers of procedures, complications, and deaths were investigated. RESULTS: The response rate was 79.1% (421 facilities). Deaths attributable to diagnostic bronchoscopy occurred in 11 (0.011%) of 98,497 cases. In regards to forceps biopsy, the guide sheath method was applied in 23,916 cases and the conventional method in 31,419 cases was done with conventional method. Complications of forceps biopsy developed in 1019 cases in total, with an incidence rate of 1.84%. The most frequent complication was pneumothorax (0.70%), followed by pneumonia/pleurisy (0.46%) and hemorrhage (0.45%). The incidence of hemorrhagic complication was significantly lower in the guide sheath group than in the non-guide sheath group (0.29% vs. 0.58%; P<0.001). The overall incidence of complications (1.63% vs. 2.00%; P=0.002) and the mortality rate (0% vs. 0.02%; P=0.04) were significantly lower in the guide sheath group. CONCLUSION: The incidence of hemorrhagic complications in forceps biopsy of peripheral pulmonary lesions was lower when the guide sheath method was applied. It is necessary to increase the awareness for safety control in diagnostic bronchoscopy for new procedures. |
format | Online Article Text |
id | pubmed-7523573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-75235732020-10-14 The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy Horinouchi, Hirohisa Asano, Fumihiro Okubo, Kenichi Okada, Yoshinori Ohsaki, Yoshinobu Komase, Yuko Hashizume, Toshinori Kohno, Mitsutomo Aoe, Motoi J Bronchology Interv Pulmonol Original Investigations BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The survey form was mailed to 532 facilities accredited by the society. The numbers of procedures, complications, and deaths were investigated. RESULTS: The response rate was 79.1% (421 facilities). Deaths attributable to diagnostic bronchoscopy occurred in 11 (0.011%) of 98,497 cases. In regards to forceps biopsy, the guide sheath method was applied in 23,916 cases and the conventional method in 31,419 cases was done with conventional method. Complications of forceps biopsy developed in 1019 cases in total, with an incidence rate of 1.84%. The most frequent complication was pneumothorax (0.70%), followed by pneumonia/pleurisy (0.46%) and hemorrhage (0.45%). The incidence of hemorrhagic complication was significantly lower in the guide sheath group than in the non-guide sheath group (0.29% vs. 0.58%; P<0.001). The overall incidence of complications (1.63% vs. 2.00%; P=0.002) and the mortality rate (0% vs. 0.02%; P=0.04) were significantly lower in the guide sheath group. CONCLUSION: The incidence of hemorrhagic complications in forceps biopsy of peripheral pulmonary lesions was lower when the guide sheath method was applied. It is necessary to increase the awareness for safety control in diagnostic bronchoscopy for new procedures. Lippincott Williams & Wilkins 2020-10 2020-04-09 /pmc/articles/PMC7523573/ /pubmed/32282445 http://dx.doi.org/10.1097/LBR.0000000000000669 Text en Copyright © 2020 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/) (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/ |
spellingShingle | Original Investigations Horinouchi, Hirohisa Asano, Fumihiro Okubo, Kenichi Okada, Yoshinori Ohsaki, Yoshinobu Komase, Yuko Hashizume, Toshinori Kohno, Mitsutomo Aoe, Motoi The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title | The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title_full | The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title_fullStr | The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title_full_unstemmed | The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title_short | The Incidence of Hemorrhagic Complications Was Lower With the Guide Sheath Than With the Conventional Forceps Biopsy Method: Results of Bronchoscopy in the 2016 Nationwide Survey by the Japan Society for Respiratory Endoscopy |
title_sort | incidence of hemorrhagic complications was lower with the guide sheath than with the conventional forceps biopsy method: results of bronchoscopy in the 2016 nationwide survey by the japan society for respiratory endoscopy |
topic | Original Investigations |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7523573/ https://www.ncbi.nlm.nih.gov/pubmed/32282445 http://dx.doi.org/10.1097/LBR.0000000000000669 |
work_keys_str_mv | AT horinouchihirohisa theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT asanofumihiro theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT okubokenichi theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT okadayoshinori theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT ohsakiyoshinobu theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT komaseyuko theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT hashizumetoshinori theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT kohnomitsutomo theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT aoemotoi theincidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT horinouchihirohisa incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT asanofumihiro incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT okubokenichi incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT okadayoshinori incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT ohsakiyoshinobu incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT komaseyuko incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT hashizumetoshinori incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT kohnomitsutomo incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy AT aoemotoi incidenceofhemorrhagiccomplicationswaslowerwiththeguidesheaththanwiththeconventionalforcepsbiopsymethodresultsofbronchoscopyinthe2016nationwidesurveybythejapansocietyforrespiratoryendoscopy |