Cargando…
Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience
BACKGROUND: In this study, we sought to evaluate the feasibility of improved transcatheter aortic valve implantation (TAVI) in noncalcified aortic valve by using the novel concept of double-layer ChenValve prosthesis. TAVI was initially considered as an alternative treatment for high-risk patients w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7525934/ https://www.ncbi.nlm.nih.gov/pubmed/32993717 http://dx.doi.org/10.1186/s13019-020-01327-4 |
_version_ | 1783588776811954176 |
---|---|
author | Kan, Tong Gu, Lan Lu, Hongjiang Cao, Junxiong Zhu, Zhijun Wu, Danning Zhu, Zhidong Chen, Xiang |
author_facet | Kan, Tong Gu, Lan Lu, Hongjiang Cao, Junxiong Zhu, Zhijun Wu, Danning Zhu, Zhidong Chen, Xiang |
author_sort | Kan, Tong |
collection | PubMed |
description | BACKGROUND: In this study, we sought to evaluate the feasibility of improved transcatheter aortic valve implantation (TAVI) in noncalcified aortic valve by using the novel concept of double-layer ChenValve prosthesis. TAVI was initially considered as an alternative treatment for high-risk patients with aortic stenosis. However, non noncalcified aortic valve disease was considered as a contraindication to TAVI. METHODS: ChenValve prosthesis, which consisted of a self-expanding Nitinol ring, a balloon-expandable cobalt-chromium alloy stent and a biological valve, was implanted at the desired position under fluoroscopic guidance in a transapical approach through a 20F sheath in 10 goats. Aortic angiography was performed to measure the diameter of the aotic annulus and assess the performance of the artificial valve. The ultrasound was used to evaluate the regurgitation or paravalvular leakage and trans-prosthetic vascular flow velocity postoperatively. The aortogram and transthoracic echocardiography were applied to observe whether the valve stent was implanted at the desired position. RESULTS: ChenValve prosthesis was successfully transppical implanted in all animals. The aortogram and transthoracic echocardiography performed immediately after implantation revealed that the valve stent was implanted at the desired position. There was no significant paravalvular leakage, obstruction of coronary artery ostia, stent malpositioning or dislodgement occurred. CONCLUSIONS: This preliminary trial with the novel double-layer ChenValve prosthesis demonstrated the feasibility of improved TAVI in noncalcified aortic valve. The mechanism of Nitinol ring-guided locating the aortic sinus enables us to anatomically correct position the artifact valve. This improved strategy seems to make the TAVI process more safe and repeatable in noncalcified aortic valve. |
format | Online Article Text |
id | pubmed-7525934 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-75259342020-09-30 Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience Kan, Tong Gu, Lan Lu, Hongjiang Cao, Junxiong Zhu, Zhijun Wu, Danning Zhu, Zhidong Chen, Xiang J Cardiothorac Surg Research Article BACKGROUND: In this study, we sought to evaluate the feasibility of improved transcatheter aortic valve implantation (TAVI) in noncalcified aortic valve by using the novel concept of double-layer ChenValve prosthesis. TAVI was initially considered as an alternative treatment for high-risk patients with aortic stenosis. However, non noncalcified aortic valve disease was considered as a contraindication to TAVI. METHODS: ChenValve prosthesis, which consisted of a self-expanding Nitinol ring, a balloon-expandable cobalt-chromium alloy stent and a biological valve, was implanted at the desired position under fluoroscopic guidance in a transapical approach through a 20F sheath in 10 goats. Aortic angiography was performed to measure the diameter of the aotic annulus and assess the performance of the artificial valve. The ultrasound was used to evaluate the regurgitation or paravalvular leakage and trans-prosthetic vascular flow velocity postoperatively. The aortogram and transthoracic echocardiography were applied to observe whether the valve stent was implanted at the desired position. RESULTS: ChenValve prosthesis was successfully transppical implanted in all animals. The aortogram and transthoracic echocardiography performed immediately after implantation revealed that the valve stent was implanted at the desired position. There was no significant paravalvular leakage, obstruction of coronary artery ostia, stent malpositioning or dislodgement occurred. CONCLUSIONS: This preliminary trial with the novel double-layer ChenValve prosthesis demonstrated the feasibility of improved TAVI in noncalcified aortic valve. The mechanism of Nitinol ring-guided locating the aortic sinus enables us to anatomically correct position the artifact valve. This improved strategy seems to make the TAVI process more safe and repeatable in noncalcified aortic valve. BioMed Central 2020-09-29 /pmc/articles/PMC7525934/ /pubmed/32993717 http://dx.doi.org/10.1186/s13019-020-01327-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Kan, Tong Gu, Lan Lu, Hongjiang Cao, Junxiong Zhu, Zhijun Wu, Danning Zhu, Zhidong Chen, Xiang Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title | Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title_full | Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title_fullStr | Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title_full_unstemmed | Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title_short | Improved Transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
title_sort | improved transcatheter aortic valve implantation for aortic regurgitation using a new-type stent: the first preclinical experience |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7525934/ https://www.ncbi.nlm.nih.gov/pubmed/32993717 http://dx.doi.org/10.1186/s13019-020-01327-4 |
work_keys_str_mv | AT kantong improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT gulan improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT luhongjiang improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT caojunxiong improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT zhuzhijun improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT wudanning improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT zhuzhidong improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience AT chenxiang improvedtranscatheteraorticvalveimplantationforaorticregurgitationusinganewtypestentthefirstpreclinicalexperience |