Cargando…

Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants

Wastewater treatment plants (WWTPs) could emit a large amount of bioaerosols containing pathogenic bacteria. Assessing the health risks of exposure to these bioaerosols by using quantitative microbial risk assessment (QMRA) is important to protect workers in WWTPs. However, the relative impacts of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Yan-huan, Yan, Cheng, Yang, Ya-fei, Ma, Jia-xin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7527313/
https://www.ncbi.nlm.nih.gov/pubmed/33038813
http://dx.doi.org/10.1016/j.scitotenv.2020.142615
_version_ 1783589029161205760
author Chen, Yan-huan
Yan, Cheng
Yang, Ya-fei
Ma, Jia-xin
author_facet Chen, Yan-huan
Yan, Cheng
Yang, Ya-fei
Ma, Jia-xin
author_sort Chen, Yan-huan
collection PubMed
description Wastewater treatment plants (WWTPs) could emit a large amount of bioaerosols containing pathogenic bacteria. Assessing the health risks of exposure to these bioaerosols by using quantitative microbial risk assessment (QMRA) is important to protect workers in WWTPs. However, the relative impacts of the stochastic input variables on the health risks determined in QMRA remain vague. Hence, this study performed a Monte Carlo simulation-based QMRA case study for workers exposing to S. aureus or E. coli bioaerosols and a sensitivity analysis in two WWTPs with various aeration modes. Results showed that when workers equipped without personal protective equipment (PPE) were exposed to S. aureus or E. coli bioaerosol in the two WWTPs, the annual probability of infection considerably exceeded the U.S. EPA benchmark (≤10E-4 pppy), and the disease burden did not satisfy the WHO benchmark (≤10E-6 DALYs pppy) (except exposure to E. coli bioaerosol for disease health risk burden). Nevertheless, the use of PPE effectively reduced the annual infection health risk to an acceptable level and converted the disease health risk burden to a highly acceptable level. Referring to the sensitivity analysis, the contribution of mechanical aeration modes to the variability of the health risks was absolutely dominated in the WWTPs. On the aeration mode that showed high exposure concentration, the three input exposure parameters (exposure time, aerosol ingestion rate, and breathing rate) had a great impact on health risks. The health risks were also prone to being highly influenced by the various choices of the dose–response model and related parameters. Current research systematically delivered new data and a novel perspective on the sensitivity analysis of QMRA. Then, management decisions could be executed by authorities on the basis of the results of this sensitivity analysis to reduce related occupational health risks of workers in WWTPs.
format Online
Article
Text
id pubmed-7527313
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-75273132020-10-01 Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants Chen, Yan-huan Yan, Cheng Yang, Ya-fei Ma, Jia-xin Sci Total Environ Article Wastewater treatment plants (WWTPs) could emit a large amount of bioaerosols containing pathogenic bacteria. Assessing the health risks of exposure to these bioaerosols by using quantitative microbial risk assessment (QMRA) is important to protect workers in WWTPs. However, the relative impacts of the stochastic input variables on the health risks determined in QMRA remain vague. Hence, this study performed a Monte Carlo simulation-based QMRA case study for workers exposing to S. aureus or E. coli bioaerosols and a sensitivity analysis in two WWTPs with various aeration modes. Results showed that when workers equipped without personal protective equipment (PPE) were exposed to S. aureus or E. coli bioaerosol in the two WWTPs, the annual probability of infection considerably exceeded the U.S. EPA benchmark (≤10E-4 pppy), and the disease burden did not satisfy the WHO benchmark (≤10E-6 DALYs pppy) (except exposure to E. coli bioaerosol for disease health risk burden). Nevertheless, the use of PPE effectively reduced the annual infection health risk to an acceptable level and converted the disease health risk burden to a highly acceptable level. Referring to the sensitivity analysis, the contribution of mechanical aeration modes to the variability of the health risks was absolutely dominated in the WWTPs. On the aeration mode that showed high exposure concentration, the three input exposure parameters (exposure time, aerosol ingestion rate, and breathing rate) had a great impact on health risks. The health risks were also prone to being highly influenced by the various choices of the dose–response model and related parameters. Current research systematically delivered new data and a novel perspective on the sensitivity analysis of QMRA. Then, management decisions could be executed by authorities on the basis of the results of this sensitivity analysis to reduce related occupational health risks of workers in WWTPs. Elsevier B.V. 2021-02-10 2020-10-01 /pmc/articles/PMC7527313/ /pubmed/33038813 http://dx.doi.org/10.1016/j.scitotenv.2020.142615 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Chen, Yan-huan
Yan, Cheng
Yang, Ya-fei
Ma, Jia-xin
Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title_full Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title_fullStr Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title_full_unstemmed Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title_short Quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
title_sort quantitative microbial risk assessment and sensitivity analysis for workers exposed to pathogenic bacterial bioaerosols under various aeration modes in two wastewater treatment plants
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7527313/
https://www.ncbi.nlm.nih.gov/pubmed/33038813
http://dx.doi.org/10.1016/j.scitotenv.2020.142615
work_keys_str_mv AT chenyanhuan quantitativemicrobialriskassessmentandsensitivityanalysisforworkersexposedtopathogenicbacterialbioaerosolsundervariousaerationmodesintwowastewatertreatmentplants
AT yancheng quantitativemicrobialriskassessmentandsensitivityanalysisforworkersexposedtopathogenicbacterialbioaerosolsundervariousaerationmodesintwowastewatertreatmentplants
AT yangyafei quantitativemicrobialriskassessmentandsensitivityanalysisforworkersexposedtopathogenicbacterialbioaerosolsundervariousaerationmodesintwowastewatertreatmentplants
AT majiaxin quantitativemicrobialriskassessmentandsensitivityanalysisforworkersexposedtopathogenicbacterialbioaerosolsundervariousaerationmodesintwowastewatertreatmentplants