Cargando…

A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories

[Image: see text] This work presents a non-targeted high-resolution mass spectrometry inter-laboratory study for the detection of new chemical markers responsible of soft refined oils addition to extra virgin olive oils. Refined oils (soft deodorized and soft deacidified) were prepared on a laborato...

Descripción completa

Detalles Bibliográficos
Autores principales: Cavanna, Daniele, Hurkova, Kamila, Džuman, Zbyněk, Serani, Andrea, Serani, Matteo, Dall’Asta, Chiara, Tomaniova, Monika, Hajslova, Jana, Suman, Michele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7528164/
https://www.ncbi.nlm.nih.gov/pubmed/33015432
http://dx.doi.org/10.1021/acsomega.0c00346
_version_ 1783589205747695616
author Cavanna, Daniele
Hurkova, Kamila
Džuman, Zbyněk
Serani, Andrea
Serani, Matteo
Dall’Asta, Chiara
Tomaniova, Monika
Hajslova, Jana
Suman, Michele
author_facet Cavanna, Daniele
Hurkova, Kamila
Džuman, Zbyněk
Serani, Andrea
Serani, Matteo
Dall’Asta, Chiara
Tomaniova, Monika
Hajslova, Jana
Suman, Michele
author_sort Cavanna, Daniele
collection PubMed
description [Image: see text] This work presents a non-targeted high-resolution mass spectrometry inter-laboratory study for the detection of new chemical markers responsible of soft refined oils addition to extra virgin olive oils. Refined oils (soft deodorized and soft deacidified) were prepared on a laboratory scale starting from low-quality olive oils and analyzed together with a set of pure extra virgin olive oil (EVOO) samples and with mixtures of adulterated and pure EVOO at different percentages. The same analytical workflow was applied in two different laboratories equipped with two types of instrumentation (Q-Orbitrap and Q-TOF); a group of discriminant molecules was selected, and a tentative identification of compounds was also proposed. In summary, 12 molecules were identified as markers of this specific adulteration, and seven of them were selected as discriminative in both the laboratories, with a similar trend throughout the samples (i.e., propylene glycol 1 stearate). The results obtained in the two laboratories are comparable, concretely demonstrating the inter-laboratory repeatability of non-targeted studies. As a confirmation, the same markers were detected also in “in-house” mixtures and in suspect commercial deodorized mixtures, reinforcing the robustness of the results obtained and proving that, thanks to these molecules, mixtures containing at least 40% of adulterated oils can be detected.
format Online
Article
Text
id pubmed-7528164
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-75281642020-10-02 A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories Cavanna, Daniele Hurkova, Kamila Džuman, Zbyněk Serani, Andrea Serani, Matteo Dall’Asta, Chiara Tomaniova, Monika Hajslova, Jana Suman, Michele ACS Omega [Image: see text] This work presents a non-targeted high-resolution mass spectrometry inter-laboratory study for the detection of new chemical markers responsible of soft refined oils addition to extra virgin olive oils. Refined oils (soft deodorized and soft deacidified) were prepared on a laboratory scale starting from low-quality olive oils and analyzed together with a set of pure extra virgin olive oil (EVOO) samples and with mixtures of adulterated and pure EVOO at different percentages. The same analytical workflow was applied in two different laboratories equipped with two types of instrumentation (Q-Orbitrap and Q-TOF); a group of discriminant molecules was selected, and a tentative identification of compounds was also proposed. In summary, 12 molecules were identified as markers of this specific adulteration, and seven of them were selected as discriminative in both the laboratories, with a similar trend throughout the samples (i.e., propylene glycol 1 stearate). The results obtained in the two laboratories are comparable, concretely demonstrating the inter-laboratory repeatability of non-targeted studies. As a confirmation, the same markers were detected also in “in-house” mixtures and in suspect commercial deodorized mixtures, reinforcing the robustness of the results obtained and proving that, thanks to these molecules, mixtures containing at least 40% of adulterated oils can be detected. American Chemical Society 2020-09-15 /pmc/articles/PMC7528164/ /pubmed/33015432 http://dx.doi.org/10.1021/acsomega.0c00346 Text en This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Cavanna, Daniele
Hurkova, Kamila
Džuman, Zbyněk
Serani, Andrea
Serani, Matteo
Dall’Asta, Chiara
Tomaniova, Monika
Hajslova, Jana
Suman, Michele
A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title_full A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title_fullStr A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title_full_unstemmed A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title_short A Non-Targeted High-Resolution Mass Spectrometry Study for Extra Virgin Olive Oil Adulteration with Soft Refined Oils: Preliminary Findings from Two Different Laboratories
title_sort non-targeted high-resolution mass spectrometry study for extra virgin olive oil adulteration with soft refined oils: preliminary findings from two different laboratories
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7528164/
https://www.ncbi.nlm.nih.gov/pubmed/33015432
http://dx.doi.org/10.1021/acsomega.0c00346
work_keys_str_mv AT cavannadaniele anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT hurkovakamila anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT dzumanzbynek anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT seraniandrea anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT seranimatteo anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT dallastachiara anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT tomaniovamonika anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT hajslovajana anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT sumanmichele anontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT cavannadaniele nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT hurkovakamila nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT dzumanzbynek nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT seraniandrea nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT seranimatteo nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT dallastachiara nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT tomaniovamonika nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT hajslovajana nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories
AT sumanmichele nontargetedhighresolutionmassspectrometrystudyforextravirginoliveoiladulterationwithsoftrefinedoilspreliminaryfindingsfromtwodifferentlaboratories