Cargando…

Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients

INTRODUCTION: Measurement of an- hippocampal area or volume is useful in clinical practice as a supportive aid for diagnosis of Alzheimer's disease. Since it is time-consuming and not simple, it is not being used very often. We present a simplified protocol for hippocampal atrophy evaluation ba...

Descripción completa

Detalles Bibliográficos
Autores principales: Zach, P., Bartoš, A., Lagutina, A., Wurst, Z., Gallina, P., Rai, T., Kieslich, K., Riedlová, J., Ibrahim, I., Tintěra, J., Mrzílková, J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7532424/
https://www.ncbi.nlm.nih.gov/pubmed/33029517
http://dx.doi.org/10.1155/2020/5894021
_version_ 1783589920756989952
author Zach, P.
Bartoš, A.
Lagutina, A.
Wurst, Z.
Gallina, P.
Rai, T.
Kieslich, K.
Riedlová, J.
Ibrahim, I.
Tintěra, J.
Mrzílková, J.
author_facet Zach, P.
Bartoš, A.
Lagutina, A.
Wurst, Z.
Gallina, P.
Rai, T.
Kieslich, K.
Riedlová, J.
Ibrahim, I.
Tintěra, J.
Mrzílková, J.
author_sort Zach, P.
collection PubMed
description INTRODUCTION: Measurement of an- hippocampal area or volume is useful in clinical practice as a supportive aid for diagnosis of Alzheimer's disease. Since it is time-consuming and not simple, it is not being used very often. We present a simplified protocol for hippocampal atrophy evaluation based on a single optimal slice in Alzheimer's disease. METHODS: We defined a single optimal slice for hippocampal measurement on brain magnetic resonance imaging (MRI) at the plane where the amygdala disappears and only the hippocampus is present. We compared an absolute area and volume of the hippocampus on this optimal slice between 40 patients with Alzheimer disease and 40 age-, education- and gender-mateched elderly controls. Furthermore, we compared these results with those relative to the size of the brain or the skull: the area of the optimal slice normalized to the area of the brain at anterior commissure and the volume of the hippocampus normalized to the total intracranial volume. RESULTS: Hippocampal areas on the single optimal slice and hippocampal volumes on the left and right in the control group were significantly higher than those in the AD group. Normalized hippocampal areas and volumes on the left and right in the control group were significantly higher compared to the AD group. Absolute hippocampal areas and volumes did not significantly differ from corresponding normalized hippocampal areas as well as normalized hippocampal volumes using comparisons of areas under the receiver operating characteristic curves. CONCLUSION: The hippocampal area on the well-defined optimal slice of brain MRI can reliably substitute a complicated measurement of the hippocampal volume. Surprisingly, brain or skull normalization of these variables does not add any incremental differentiation between Alzheimer disease patients and controls or give better results.
format Online
Article
Text
id pubmed-7532424
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-75324242020-10-06 Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients Zach, P. Bartoš, A. Lagutina, A. Wurst, Z. Gallina, P. Rai, T. Kieslich, K. Riedlová, J. Ibrahim, I. Tintěra, J. Mrzílková, J. Biomed Res Int Research Article INTRODUCTION: Measurement of an- hippocampal area or volume is useful in clinical practice as a supportive aid for diagnosis of Alzheimer's disease. Since it is time-consuming and not simple, it is not being used very often. We present a simplified protocol for hippocampal atrophy evaluation based on a single optimal slice in Alzheimer's disease. METHODS: We defined a single optimal slice for hippocampal measurement on brain magnetic resonance imaging (MRI) at the plane where the amygdala disappears and only the hippocampus is present. We compared an absolute area and volume of the hippocampus on this optimal slice between 40 patients with Alzheimer disease and 40 age-, education- and gender-mateched elderly controls. Furthermore, we compared these results with those relative to the size of the brain or the skull: the area of the optimal slice normalized to the area of the brain at anterior commissure and the volume of the hippocampus normalized to the total intracranial volume. RESULTS: Hippocampal areas on the single optimal slice and hippocampal volumes on the left and right in the control group were significantly higher than those in the AD group. Normalized hippocampal areas and volumes on the left and right in the control group were significantly higher compared to the AD group. Absolute hippocampal areas and volumes did not significantly differ from corresponding normalized hippocampal areas as well as normalized hippocampal volumes using comparisons of areas under the receiver operating characteristic curves. CONCLUSION: The hippocampal area on the well-defined optimal slice of brain MRI can reliably substitute a complicated measurement of the hippocampal volume. Surprisingly, brain or skull normalization of these variables does not add any incremental differentiation between Alzheimer disease patients and controls or give better results. Hindawi 2020-09-23 /pmc/articles/PMC7532424/ /pubmed/33029517 http://dx.doi.org/10.1155/2020/5894021 Text en Copyright © 2020 P. Zach et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zach, P.
Bartoš, A.
Lagutina, A.
Wurst, Z.
Gallina, P.
Rai, T.
Kieslich, K.
Riedlová, J.
Ibrahim, I.
Tintěra, J.
Mrzílková, J.
Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title_full Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title_fullStr Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title_full_unstemmed Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title_short Easy Identification of Optimal Coronal Slice on Brain Magnetic Resonance Imaging to Measure Hippocampal Area in Alzheimer's Disease Patients
title_sort easy identification of optimal coronal slice on brain magnetic resonance imaging to measure hippocampal area in alzheimer's disease patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7532424/
https://www.ncbi.nlm.nih.gov/pubmed/33029517
http://dx.doi.org/10.1155/2020/5894021
work_keys_str_mv AT zachp easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT bartosa easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT lagutinaa easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT wurstz easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT gallinap easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT rait easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT kieslichk easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT riedlovaj easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT ibrahimi easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT tinteraj easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients
AT mrzilkovaj easyidentificationofoptimalcoronalsliceonbrainmagneticresonanceimagingtomeasurehippocampalareainalzheimersdiseasepatients