Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns
To develop an electronic navigation system to increase reliability and comparability in the ultrasound screening of developmental dysplasia of the hip (DDH). The impact of the navigation system on transducer positioning and on sonographic measurements according to Graf was analyzed. Twenty hips in n...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7532432/ https://www.ncbi.nlm.nih.gov/pubmed/33009470 http://dx.doi.org/10.1038/s41598-020-73536-9 |
_version_ | 1783589922638135296 |
---|---|
author | Kolb, Alexander Chiari, Catharina Schreiner, Markus Heisinger, Stephan Willegger, Madeleine Rettl, Gregor Windhager, Reinhard |
author_facet | Kolb, Alexander Chiari, Catharina Schreiner, Markus Heisinger, Stephan Willegger, Madeleine Rettl, Gregor Windhager, Reinhard |
author_sort | Kolb, Alexander |
collection | PubMed |
description | To develop an electronic navigation system to increase reliability and comparability in the ultrasound screening of developmental dysplasia of the hip (DDH). The impact of the navigation system on transducer positioning and on sonographic measurements according to Graf was analyzed. Twenty hips in newborns were examined sonographically using a new navigation system capable of detecting the transducer and pelvis position in order to calculate the relative tilt in the frontal, axial, and sagittal-plane. In each newborn an ultrasound image was obtained conventionally according to Graf and a second image using the sonographic navigation system. Relative roll and pitch angles and sonographic measurements were analyzed using paired T-tests and Levene-tests. Relative tilt angles in the conventional group ranged from − 8.9° to 14.3° (frontal-plane) and − 23.8° to 14.2° (axial-plane). In the navigation-assisted group ranges from − 3.0° to 3.5° and − 2.8° to 4.5° were observed. Variances were significantly lower in the navigation-assisted group (p < 0.001 and p = 0.004 respectively). The navigation system allowed for a significant reduction of relative tilt angles between the transducer and the newborn pelvis, thus supporting an optimal transducer positioning. This is a promising approach to improve reproducibility and reliability in the ultrasound screening for DDH. |
format | Online Article Text |
id | pubmed-7532432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-75324322020-10-06 Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns Kolb, Alexander Chiari, Catharina Schreiner, Markus Heisinger, Stephan Willegger, Madeleine Rettl, Gregor Windhager, Reinhard Sci Rep Article To develop an electronic navigation system to increase reliability and comparability in the ultrasound screening of developmental dysplasia of the hip (DDH). The impact of the navigation system on transducer positioning and on sonographic measurements according to Graf was analyzed. Twenty hips in newborns were examined sonographically using a new navigation system capable of detecting the transducer and pelvis position in order to calculate the relative tilt in the frontal, axial, and sagittal-plane. In each newborn an ultrasound image was obtained conventionally according to Graf and a second image using the sonographic navigation system. Relative roll and pitch angles and sonographic measurements were analyzed using paired T-tests and Levene-tests. Relative tilt angles in the conventional group ranged from − 8.9° to 14.3° (frontal-plane) and − 23.8° to 14.2° (axial-plane). In the navigation-assisted group ranges from − 3.0° to 3.5° and − 2.8° to 4.5° were observed. Variances were significantly lower in the navigation-assisted group (p < 0.001 and p = 0.004 respectively). The navigation system allowed for a significant reduction of relative tilt angles between the transducer and the newborn pelvis, thus supporting an optimal transducer positioning. This is a promising approach to improve reproducibility and reliability in the ultrasound screening for DDH. Nature Publishing Group UK 2020-10-02 /pmc/articles/PMC7532432/ /pubmed/33009470 http://dx.doi.org/10.1038/s41598-020-73536-9 Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Kolb, Alexander Chiari, Catharina Schreiner, Markus Heisinger, Stephan Willegger, Madeleine Rettl, Gregor Windhager, Reinhard Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title | Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title_full | Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title_fullStr | Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title_full_unstemmed | Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title_short | Development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
title_sort | development of an electronic navigation system for elimination of examiner-dependent factors in the ultrasound screening for developmental dysplasia of the hip in newborns |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7532432/ https://www.ncbi.nlm.nih.gov/pubmed/33009470 http://dx.doi.org/10.1038/s41598-020-73536-9 |
work_keys_str_mv | AT kolbalexander developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT chiaricatharina developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT schreinermarkus developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT heisingerstephan developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT willeggermadeleine developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT rettlgregor developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns AT windhagerreinhard developmentofanelectronicnavigationsystemforeliminationofexaminerdependentfactorsintheultrasoundscreeningfordevelopmentaldysplasiaofthehipinnewborns |