Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods

OBJECTIVES: Single-photon emission computed tomography/computed tomography (SPECT/CT) hybrid systems have the advantage of performing various scans using the same imaging setting. Absorption and scattering of the gamma rays by the patient’s body significantly affect images obtained from scintigraphy...

Descripción completa

Detalles Bibliográficos
Autores principales: Tantawy, Hazem M., Abdelhafez, Yasser G., Helal, Nadia L., Saad, Ibrahim E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Scientific Scholar 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7533088/
https://www.ncbi.nlm.nih.gov/pubmed/33024613
http://dx.doi.org/10.25259/JCIS_123_2020
_version_ 1783590062076723200
author Tantawy, Hazem M.
Abdelhafez, Yasser G.
Helal, Nadia L.
Saad, Ibrahim E.
author_facet Tantawy, Hazem M.
Abdelhafez, Yasser G.
Helal, Nadia L.
Saad, Ibrahim E.
author_sort Tantawy, Hazem M.
collection PubMed
description OBJECTIVES: Single-photon emission computed tomography/computed tomography (SPECT/CT) hybrid systems have the advantage of performing various scans using the same imaging setting. Absorption and scattering of the gamma rays by the patient’s body significantly affect images obtained from scintigraphy, especially in myocardial perfusion imaging. An important parameter for image quality in SPECT is image contrast which is defined as the difference in density between regions of the image corresponding to different levels of radioactive uptake in the patient. The objective of the study was to evaluate the influence of applying different correction methods on image contrast of myocardial SPECT/CT images. MATERIAL AND METHODS: A total of 114 patients, 43 females and 71 males, patient’s raw data were processed and analyzed using attenuation correction (AC), scatter correction (SC), both attenuation and scatter correction together (ACSC), and no correction (NC). The short axis (coronal) slices resulted from the raw data reconstruction were chosen to perform the processing for hot and cold spheres for contrast values measurement. Statistical analysis was made for the measured contrast values for AC, SC, ACSC, and NC to determine the best image contrast. RESULTS: When applying SC alone, it yields better contrast value (0.834), compared to AC (0.677) and ACSC (0.739). Both ACSC and AC had better image contrast compared to NC (0.592). CONCLUSION: The intercomparison study between the correction conditions indicates that the counts in SPECT/ CT are highly affected by all correction methods. The image contrast has been significantly improved by using SC, AC, and ACSC when compared with the NC image. Furthermore, SC is superior in the image contrast than the other correction conditions in the reconstruction of SPECT/CT MPI.
format Online
Article
Text
id pubmed-7533088
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Scientific Scholar
record_format MEDLINE/PubMed
spelling pubmed-75330882020-10-05 Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods Tantawy, Hazem M. Abdelhafez, Yasser G. Helal, Nadia L. Saad, Ibrahim E. J Clin Imaging Sci Original Research OBJECTIVES: Single-photon emission computed tomography/computed tomography (SPECT/CT) hybrid systems have the advantage of performing various scans using the same imaging setting. Absorption and scattering of the gamma rays by the patient’s body significantly affect images obtained from scintigraphy, especially in myocardial perfusion imaging. An important parameter for image quality in SPECT is image contrast which is defined as the difference in density between regions of the image corresponding to different levels of radioactive uptake in the patient. The objective of the study was to evaluate the influence of applying different correction methods on image contrast of myocardial SPECT/CT images. MATERIAL AND METHODS: A total of 114 patients, 43 females and 71 males, patient’s raw data were processed and analyzed using attenuation correction (AC), scatter correction (SC), both attenuation and scatter correction together (ACSC), and no correction (NC). The short axis (coronal) slices resulted from the raw data reconstruction were chosen to perform the processing for hot and cold spheres for contrast values measurement. Statistical analysis was made for the measured contrast values for AC, SC, ACSC, and NC to determine the best image contrast. RESULTS: When applying SC alone, it yields better contrast value (0.834), compared to AC (0.677) and ACSC (0.739). Both ACSC and AC had better image contrast compared to NC (0.592). CONCLUSION: The intercomparison study between the correction conditions indicates that the counts in SPECT/ CT are highly affected by all correction methods. The image contrast has been significantly improved by using SC, AC, and ACSC when compared with the NC image. Furthermore, SC is superior in the image contrast than the other correction conditions in the reconstruction of SPECT/CT MPI. Scientific Scholar 2020-09-25 /pmc/articles/PMC7533088/ /pubmed/33024613 http://dx.doi.org/10.25259/JCIS_123_2020 Text en © 2020 Published by Scientific Scholar on behalf of Journal of Clinical Imaging Science https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Research
Tantawy, Hazem M.
Abdelhafez, Yasser G.
Helal, Nadia L.
Saad, Ibrahim E.
Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title_full Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title_fullStr Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title_full_unstemmed Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title_short Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
title_sort variation of contrast values for myocardial perfusion imaging in single-photon emission computed tomography/computed tomography hybrid systems with different correction methods
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7533088/
https://www.ncbi.nlm.nih.gov/pubmed/33024613
http://dx.doi.org/10.25259/JCIS_123_2020
work_keys_str_mv AT tantawyhazemm variationofcontrastvaluesformyocardialperfusionimaginginsinglephotonemissioncomputedtomographycomputedtomographyhybridsystemswithdifferentcorrectionmethods
AT abdelhafezyasserg variationofcontrastvaluesformyocardialperfusionimaginginsinglephotonemissioncomputedtomographycomputedtomographyhybridsystemswithdifferentcorrectionmethods
AT helalnadial variationofcontrastvaluesformyocardialperfusionimaginginsinglephotonemissioncomputedtomographycomputedtomographyhybridsystemswithdifferentcorrectionmethods
AT saadibrahime variationofcontrastvaluesformyocardialperfusionimaginginsinglephotonemissioncomputedtomographycomputedtomographyhybridsystemswithdifferentcorrectionmethods