Cargando…

Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer

BACKGROUND: Contrast-enhanced spectral mammography (CESM) is digital mammography with contrast agent. This promising new breast imaging method can be used for planning surgical treatment. This study compared CESM versus digital mammography (MG) in evaluating tumor size in breast cancer. MATERIAL/MET...

Descripción completa

Detalles Bibliográficos
Autores principales: Lorek, Andrzej, Steinhof-Radwańska, Katarzyna, Barczyk-Gutkowska, Anna, Zarębski, Wojciech, Boratyn-Nowicka, Agnieszka, Bobola, Agnieszka, Lorek, Joanna, Stojčev, Zoran, Gisterek, Iwona
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7534504/
https://www.ncbi.nlm.nih.gov/pubmed/32994388
http://dx.doi.org/10.12659/MSM.926977
_version_ 1783590325607989248
author Lorek, Andrzej
Steinhof-Radwańska, Katarzyna
Barczyk-Gutkowska, Anna
Zarębski, Wojciech
Boratyn-Nowicka, Agnieszka
Bobola, Agnieszka
Lorek, Joanna
Stojčev, Zoran
Gisterek, Iwona
author_facet Lorek, Andrzej
Steinhof-Radwańska, Katarzyna
Barczyk-Gutkowska, Anna
Zarębski, Wojciech
Boratyn-Nowicka, Agnieszka
Bobola, Agnieszka
Lorek, Joanna
Stojčev, Zoran
Gisterek, Iwona
author_sort Lorek, Andrzej
collection PubMed
description BACKGROUND: Contrast-enhanced spectral mammography (CESM) is digital mammography with contrast agent. This promising new breast imaging method can be used for planning surgical treatment. This study compared CESM versus digital mammography (MG) in evaluating tumor size in breast cancer. MATERIAL/METHODS: Comparison of tumor dimensions in CESM, MG, and histopathology was made. The correlation of these data was assessed by histopathological type, biological subtype, grading of the carcinoma, and patient age. RESULTS: The average difference in tumor size between CESM and histopathological examination was 5 mm. The differences in size measurement between CESM and MG were significant (p=0.00). The Pearson’s linear correlation coefficients of CESM versus HP and MG versus HP were −0.01 (p=0.79) and −0.25 (p=0.00), respectively, indicating no differences between CESM and HP based on the lesion size. A weak negative correlation between those values was observed on MG. No relationship was found between the tumor size in CESM and the biological subtype, carcinoma malignancy degree, or patient age. CONCLUSIONS: CESM is a new diagnostic method in breast cancer. The accuracy of measurement of tumor size using CESM is independent of lesion size, but it overestimates the size by 5 mm on average. The difference is not dependent on grading, biological subtype of the carcinoma, or patient age. They concern the histopathological type, and values are significantly greater in pre-invasive carcinomas.
format Online
Article
Text
id pubmed-7534504
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-75345042020-10-19 Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer Lorek, Andrzej Steinhof-Radwańska, Katarzyna Barczyk-Gutkowska, Anna Zarębski, Wojciech Boratyn-Nowicka, Agnieszka Bobola, Agnieszka Lorek, Joanna Stojčev, Zoran Gisterek, Iwona Med Sci Monit Clinical Research BACKGROUND: Contrast-enhanced spectral mammography (CESM) is digital mammography with contrast agent. This promising new breast imaging method can be used for planning surgical treatment. This study compared CESM versus digital mammography (MG) in evaluating tumor size in breast cancer. MATERIAL/METHODS: Comparison of tumor dimensions in CESM, MG, and histopathology was made. The correlation of these data was assessed by histopathological type, biological subtype, grading of the carcinoma, and patient age. RESULTS: The average difference in tumor size between CESM and histopathological examination was 5 mm. The differences in size measurement between CESM and MG were significant (p=0.00). The Pearson’s linear correlation coefficients of CESM versus HP and MG versus HP were −0.01 (p=0.79) and −0.25 (p=0.00), respectively, indicating no differences between CESM and HP based on the lesion size. A weak negative correlation between those values was observed on MG. No relationship was found between the tumor size in CESM and the biological subtype, carcinoma malignancy degree, or patient age. CONCLUSIONS: CESM is a new diagnostic method in breast cancer. The accuracy of measurement of tumor size using CESM is independent of lesion size, but it overestimates the size by 5 mm on average. The difference is not dependent on grading, biological subtype of the carcinoma, or patient age. They concern the histopathological type, and values are significantly greater in pre-invasive carcinomas. International Scientific Literature, Inc. 2020-09-30 /pmc/articles/PMC7534504/ /pubmed/32994388 http://dx.doi.org/10.12659/MSM.926977 Text en © Med Sci Monit, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Lorek, Andrzej
Steinhof-Radwańska, Katarzyna
Barczyk-Gutkowska, Anna
Zarębski, Wojciech
Boratyn-Nowicka, Agnieszka
Bobola, Agnieszka
Lorek, Joanna
Stojčev, Zoran
Gisterek, Iwona
Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title_full Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title_fullStr Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title_full_unstemmed Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title_short Retrospective Comparison of Contrast-Enhanced Spectral Mammography with Digital Mammography in Assessing Tumor Size in 668 Cases of Breast Cancer
title_sort retrospective comparison of contrast-enhanced spectral mammography with digital mammography in assessing tumor size in 668 cases of breast cancer
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7534504/
https://www.ncbi.nlm.nih.gov/pubmed/32994388
http://dx.doi.org/10.12659/MSM.926977
work_keys_str_mv AT lorekandrzej retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT steinhofradwanskakatarzyna retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT barczykgutkowskaanna retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT zarebskiwojciech retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT boratynnowickaagnieszka retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT bobolaagnieszka retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT lorekjoanna retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT stojcevzoran retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer
AT gisterekiwona retrospectivecomparisonofcontrastenhancedspectralmammographywithdigitalmammographyinassessingtumorsizein668casesofbreastcancer