Cargando…

Accuracy of a nucleocapsid protein antigen rapid test in the diagnosis of SARS-CoV-2 infection

OBJECTIVES: Rapid, reliable and easy-to-implement diagnostics that can be adapted in early severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis are critical to combat the epidemic. SARS-CoV-2 nucleocapsid protein (NP) is an ideal target for viral antigen-based detection. A rapid an...

Descripción completa

Detalles Bibliográficos
Autores principales: Diao, Bo, Wen, Kun, Zhang, Ji, Chen, Jian, Han, Chao, Chen, Yongwen, Wang, Shufeng, Deng, Guohong, Zhou, Hongwei, Wu, Yuzhang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7534827/
https://www.ncbi.nlm.nih.gov/pubmed/33031947
http://dx.doi.org/10.1016/j.cmi.2020.09.057
Descripción
Sumario:OBJECTIVES: Rapid, reliable and easy-to-implement diagnostics that can be adapted in early severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis are critical to combat the epidemic. SARS-CoV-2 nucleocapsid protein (NP) is an ideal target for viral antigen-based detection. A rapid and convenient method was developed based on fluorescence immunochromatographic (FIC) assay to detect the SARS-CoV-2 NP antigen. However, the accuracy of this diagnostic method needs to be examined. METHODS: This prospective study was carried out between 10 and 15 February 2020 in seven hospitals in Wuhan and one hospital in Chongqing, China. Participants with clinically suspected SARS-CoV-2 infection were enrolled. NP antigen testing by FIC assay and nucleic acid (NA) testing by real-time reverse transcriptase PCR (RT-PCR) were performed simultaneously in a blinded manner with the same nasopharyngeal swab sample. The diagnostic accuracy of NP antigen testing was calculated by taking NA testing of RT-PCR as the reference standard, in which samples with a cycle threshold (C(t)) value of ≤40 were interpreted as positive for SARS-CoV-2. RESULTS: A total of 253 participants were enrolled; two participants were excluded from the analyses because of invalid NP testing results. Of 251 participants (99.2%) included in the diagnostic accuracy analysis, 201 (80.1%) had a C(t) value of ≤40. With C(t) value 40 as the cutoff of NA testing, the sensitivity, specificity and percentage agreement of the FIC assay was 75.6% (95% confidence interval, 69.0–81.3), 100% (95% confidence interval, 91.1–100) and 80.5% (95% confidence interval, 75.1–84.9) respectively. CONCLUSIONS: With RT-PCR assay as the reference standard, NP antigen testing by FIC assay shows high specificity and relatively high sensitivity in SARS-CoV-2 diagnosis in the early phase of infection.