Cargando…

Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study

AIMS: The aim of this study is to compare three different methods of measuring root canal curvature and its correlation with canal access angle (CAA) in curved mesiobuccal canals of permanent mandibular first molars. MATERIALS AND METHODS: Sixty human mandibular first molars were used in this study....

Descripción completa

Detalles Bibliográficos
Autores principales: Nagmode, Pradnya Sunil, Chavan, Kanchan Manaji, Rathi, Raksha Sanjay, Tambe, Varsha Harshal, Lokhande, Nitin, Kapse, Balaji Sopanrao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7537749/
https://www.ncbi.nlm.nih.gov/pubmed/33082656
http://dx.doi.org/10.4103/JCD.JCD_259_19
_version_ 1783590727334232064
author Nagmode, Pradnya Sunil
Chavan, Kanchan Manaji
Rathi, Raksha Sanjay
Tambe, Varsha Harshal
Lokhande, Nitin
Kapse, Balaji Sopanrao
author_facet Nagmode, Pradnya Sunil
Chavan, Kanchan Manaji
Rathi, Raksha Sanjay
Tambe, Varsha Harshal
Lokhande, Nitin
Kapse, Balaji Sopanrao
author_sort Nagmode, Pradnya Sunil
collection PubMed
description AIMS: The aim of this study is to compare three different methods of measuring root canal curvature and its correlation with canal access angle (CAA) in curved mesiobuccal canals of permanent mandibular first molars. MATERIALS AND METHODS: Sixty human mandibular first molars were used in this study. Standardized access cavities were prepared. After endodontic access, a size 10 K-file was placed in the mesiobuccal canal extending to the apical foramen, and radiographs were taken. Radiographs of each root canal were taken in buccolingual direction with the long axis of the root perpendicular to the central X-ray beam. After that, the radiographs were scanned with a computer Scanner. The angles were measured using the Schneider method, Weine's method, Lutein's method, and correlated with the CAA method. The angular and linear values used in this study were plotted, and the pertinent measurements were made using the program AutoCAD R12. STATISTICAL ANALYSIS: The resultant values were evaluated statistically using ANOVA test and Pearson correlation and multiple regression analyses (P = 0.001). RESULTS: Lutein's method is as effective as the Schneider's method, Wein's method and CAA. method in evaluating root canal curvature. CONCLUSIONS: Scheider/Wein/Luiten method, together with CAA method, may be considered as a reliable guideline for preoperative assessment of canal curvature.
format Online
Article
Text
id pubmed-7537749
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-75377492020-10-19 Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study Nagmode, Pradnya Sunil Chavan, Kanchan Manaji Rathi, Raksha Sanjay Tambe, Varsha Harshal Lokhande, Nitin Kapse, Balaji Sopanrao J Conserv Dent Original Article AIMS: The aim of this study is to compare three different methods of measuring root canal curvature and its correlation with canal access angle (CAA) in curved mesiobuccal canals of permanent mandibular first molars. MATERIALS AND METHODS: Sixty human mandibular first molars were used in this study. Standardized access cavities were prepared. After endodontic access, a size 10 K-file was placed in the mesiobuccal canal extending to the apical foramen, and radiographs were taken. Radiographs of each root canal were taken in buccolingual direction with the long axis of the root perpendicular to the central X-ray beam. After that, the radiographs were scanned with a computer Scanner. The angles were measured using the Schneider method, Weine's method, Lutein's method, and correlated with the CAA method. The angular and linear values used in this study were plotted, and the pertinent measurements were made using the program AutoCAD R12. STATISTICAL ANALYSIS: The resultant values were evaluated statistically using ANOVA test and Pearson correlation and multiple regression analyses (P = 0.001). RESULTS: Lutein's method is as effective as the Schneider's method, Wein's method and CAA. method in evaluating root canal curvature. CONCLUSIONS: Scheider/Wein/Luiten method, together with CAA method, may be considered as a reliable guideline for preoperative assessment of canal curvature. Wolters Kluwer - Medknow 2019 2020-08-04 /pmc/articles/PMC7537749/ /pubmed/33082656 http://dx.doi.org/10.4103/JCD.JCD_259_19 Text en Copyright: © 2020 Journal of Conservative Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Nagmode, Pradnya Sunil
Chavan, Kanchan Manaji
Rathi, Raksha Sanjay
Tambe, Varsha Harshal
Lokhande, Nitin
Kapse, Balaji Sopanrao
Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title_full Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title_fullStr Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title_full_unstemmed Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title_short Radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: An in vitro study
title_sort radiographic evaluation of root canal curvature in mesiobuccal canals of mandibular molars by different methods and its correlation with canal access angle in curved canals: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7537749/
https://www.ncbi.nlm.nih.gov/pubmed/33082656
http://dx.doi.org/10.4103/JCD.JCD_259_19
work_keys_str_mv AT nagmodepradnyasunil radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy
AT chavankanchanmanaji radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy
AT rathirakshasanjay radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy
AT tambevarshaharshal radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy
AT lokhandenitin radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy
AT kapsebalajisopanrao radiographicevaluationofrootcanalcurvatureinmesiobuccalcanalsofmandibularmolarsbydifferentmethodsanditscorrelationwithcanalaccessangleincurvedcanalsaninvitrostudy