Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum
In the last years, microdosimetric numerical models of cells including intracellular compartments have been proposed, aiming to investigate the poration induced by the application of nanosecond pulsed electric fields (nsPEFs). A limitation of such models was the extremely approximate cell and organe...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7537786/ https://www.ncbi.nlm.nih.gov/pubmed/33072718 http://dx.doi.org/10.3389/fbioe.2020.552261 |
_version_ | 1783590735547727872 |
---|---|
author | De Angelis, Annalisa Denzi, Agnese Merla, Caterina Andre, Frank M. Mir, Lluis M. Apollonio, Francesca Liberti, Micaela |
author_facet | De Angelis, Annalisa Denzi, Agnese Merla, Caterina Andre, Frank M. Mir, Lluis M. Apollonio, Francesca Liberti, Micaela |
author_sort | De Angelis, Annalisa |
collection | PubMed |
description | In the last years, microdosimetric numerical models of cells including intracellular compartments have been proposed, aiming to investigate the poration induced by the application of nanosecond pulsed electric fields (nsPEFs). A limitation of such models was the extremely approximate cell and organelle shapes, leading to an incorrect estimation of the electric field or transmembrane potential distribution in the studied domain. In order to obtain a reliable model of in vitro experiments and a one-to-one comparison between experimental and simulated results, here, a realistic model of 12 human mesenchymal stem cells was built starting from their optical microscopy images where different cell compartments were highlighted. The microdosimetric analysis of the cells group was quantified in terms of electric field and transmembrane potentials (TMPs) induced by an externally applied 10-ns trapezoidal pulse with rise and fall times of 2 ns, with amplitudes ranging from 2 to 30 MV/m. The obtained results showed that the plasma and endoplasmic reticulum (ER) membrane of each cell respond in a different way to the same electric field amplitude, depending on differences in shape, size, and position of the single cell with respect to the applied electric field direction. Therefore, also the threshold for an efficient electroporation is highly different from cell to cell. This difference was quantitatively estimated through the cumulative distribution function of the pore density for the plasma and ER membrane of each cell, representing the probability that a certain percentage of membrane has reached a specific value of pore density. By comparing the dose-response curves resulted from the simulations and those from the experimental study of De Menorval et al. (2016), we found a very good matching of results for plasma and ER membrane when 2% of the porated area is considered sufficient for permeabilizing the membrane. This result is worth of noting as it highlights the possibility to effectively predict the behavior of a cell (or of a population of cells) exposed to nsPEFs. Therefore, the microdosimetric realistic model described here could represent a valid tool in setting up more efficient and controlled electroporation protocols. |
format | Online Article Text |
id | pubmed-7537786 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-75377862020-10-16 Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum De Angelis, Annalisa Denzi, Agnese Merla, Caterina Andre, Frank M. Mir, Lluis M. Apollonio, Francesca Liberti, Micaela Front Bioeng Biotechnol Bioengineering and Biotechnology In the last years, microdosimetric numerical models of cells including intracellular compartments have been proposed, aiming to investigate the poration induced by the application of nanosecond pulsed electric fields (nsPEFs). A limitation of such models was the extremely approximate cell and organelle shapes, leading to an incorrect estimation of the electric field or transmembrane potential distribution in the studied domain. In order to obtain a reliable model of in vitro experiments and a one-to-one comparison between experimental and simulated results, here, a realistic model of 12 human mesenchymal stem cells was built starting from their optical microscopy images where different cell compartments were highlighted. The microdosimetric analysis of the cells group was quantified in terms of electric field and transmembrane potentials (TMPs) induced by an externally applied 10-ns trapezoidal pulse with rise and fall times of 2 ns, with amplitudes ranging from 2 to 30 MV/m. The obtained results showed that the plasma and endoplasmic reticulum (ER) membrane of each cell respond in a different way to the same electric field amplitude, depending on differences in shape, size, and position of the single cell with respect to the applied electric field direction. Therefore, also the threshold for an efficient electroporation is highly different from cell to cell. This difference was quantitatively estimated through the cumulative distribution function of the pore density for the plasma and ER membrane of each cell, representing the probability that a certain percentage of membrane has reached a specific value of pore density. By comparing the dose-response curves resulted from the simulations and those from the experimental study of De Menorval et al. (2016), we found a very good matching of results for plasma and ER membrane when 2% of the porated area is considered sufficient for permeabilizing the membrane. This result is worth of noting as it highlights the possibility to effectively predict the behavior of a cell (or of a population of cells) exposed to nsPEFs. Therefore, the microdosimetric realistic model described here could represent a valid tool in setting up more efficient and controlled electroporation protocols. Frontiers Media S.A. 2020-09-22 /pmc/articles/PMC7537786/ /pubmed/33072718 http://dx.doi.org/10.3389/fbioe.2020.552261 Text en Copyright © 2020 De Angelis, Denzi, Merla, Andre, Mir, Apollonio and Liberti. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology De Angelis, Annalisa Denzi, Agnese Merla, Caterina Andre, Frank M. Mir, Lluis M. Apollonio, Francesca Liberti, Micaela Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title | Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title_full | Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title_fullStr | Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title_full_unstemmed | Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title_short | Confocal Microscopy Improves 3D Microdosimetry Applied to Nanoporation Experiments Targeting Endoplasmic Reticulum |
title_sort | confocal microscopy improves 3d microdosimetry applied to nanoporation experiments targeting endoplasmic reticulum |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7537786/ https://www.ncbi.nlm.nih.gov/pubmed/33072718 http://dx.doi.org/10.3389/fbioe.2020.552261 |
work_keys_str_mv | AT deangelisannalisa confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT denziagnese confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT merlacaterina confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT andrefrankm confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT mirlluism confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT apolloniofrancesca confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum AT libertimicaela confocalmicroscopyimproves3dmicrodosimetryappliedtonanoporationexperimentstargetingendoplasmicreticulum |