Cargando…

Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material

OBJECTIVE: Many reconstructive surgical procedures have been described for vaginal agenesis. Almost all are surgically challenging, multistage, time-consuming or leave permanent scars on the abdomen or skin removal areas. The aim of this study was to introduce a simple and cheaper approach for lapar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kılıççı, Çetin, Şanverdi, İlhan, Darıcı, Ezgi, Özkaya, Enis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7538826/
https://www.ncbi.nlm.nih.gov/pubmed/33072422
http://dx.doi.org/10.4274/tjod.galenos.2020.39112
_version_ 1783590937279070208
author Kılıççı, Çetin
Şanverdi, İlhan
Darıcı, Ezgi
Özkaya, Enis
author_facet Kılıççı, Çetin
Şanverdi, İlhan
Darıcı, Ezgi
Özkaya, Enis
author_sort Kılıççı, Çetin
collection PubMed
description OBJECTIVE: Many reconstructive surgical procedures have been described for vaginal agenesis. Almost all are surgically challenging, multistage, time-consuming or leave permanent scars on the abdomen or skin removal areas. The aim of this study was to introduce a simple and cheaper approach for laparoscopic vaginal bead-pull through. MATERIALS AND METHODS: In this retrospective study, we report a total of six patients with congenital absence of vagina [Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome] who were treated with a laparoscopic vaginal bead pull-through technique between 2018 till 2019 with a dental prosthesis material. RESULTS: Six patients with MRKH syndrome were treated with a laparoscopic vaginal bead pull-through technique. None of the women had any previous treatment. The mean age at the time of surgery was 18.7±3.1 years and mean body mass index was 25 (range, 19-38) kg/m(2). None of the patients had any additional malformations. In all patients, normal external genitalia and complete vaginal agenesis were observed during examination. The mean duration of surgery was 72 (range, 55-95) minutes. All patients were discharged on the 3(rd) postoperative day. No intraoperative complications were encountered. All patients had their urinary catheters removed within 12 hours after surgery. The mean vaginal length at discharge was 10 (range, 8-13) cm and all patients had adequate vaginal diameter, allowing introduction of three fingers easily. At the 12(th) postoperative month, the mean vaginal length was 9.2±1.6 cm. All patients had complete epithelization. All the women were sexually active one year after surgery. CONCLUSION: The laparoscopic vaginal bead pull-through technique using dental prosthesis material can provide satisfactory results with shorter surgical time and lower cost.
format Online
Article
Text
id pubmed-7538826
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-75388262020-10-15 Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material Kılıççı, Çetin Şanverdi, İlhan Darıcı, Ezgi Özkaya, Enis Turk J Obstet Gynecol Clinical Investigation OBJECTIVE: Many reconstructive surgical procedures have been described for vaginal agenesis. Almost all are surgically challenging, multistage, time-consuming or leave permanent scars on the abdomen or skin removal areas. The aim of this study was to introduce a simple and cheaper approach for laparoscopic vaginal bead-pull through. MATERIALS AND METHODS: In this retrospective study, we report a total of six patients with congenital absence of vagina [Mayer-Rokitansky-Küster-Hauser (MRKH) syndrome] who were treated with a laparoscopic vaginal bead pull-through technique between 2018 till 2019 with a dental prosthesis material. RESULTS: Six patients with MRKH syndrome were treated with a laparoscopic vaginal bead pull-through technique. None of the women had any previous treatment. The mean age at the time of surgery was 18.7±3.1 years and mean body mass index was 25 (range, 19-38) kg/m(2). None of the patients had any additional malformations. In all patients, normal external genitalia and complete vaginal agenesis were observed during examination. The mean duration of surgery was 72 (range, 55-95) minutes. All patients were discharged on the 3(rd) postoperative day. No intraoperative complications were encountered. All patients had their urinary catheters removed within 12 hours after surgery. The mean vaginal length at discharge was 10 (range, 8-13) cm and all patients had adequate vaginal diameter, allowing introduction of three fingers easily. At the 12(th) postoperative month, the mean vaginal length was 9.2±1.6 cm. All patients had complete epithelization. All the women were sexually active one year after surgery. CONCLUSION: The laparoscopic vaginal bead pull-through technique using dental prosthesis material can provide satisfactory results with shorter surgical time and lower cost. Galenos Publishing 2020-09 2020-10-02 /pmc/articles/PMC7538826/ /pubmed/33072422 http://dx.doi.org/10.4274/tjod.galenos.2020.39112 Text en ©Copyright 2020 by Turkish Society of Obstetrics and Gynecology | Turkish Journal of Obstetrics and Gynecology published by Galenos Publishing House. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Investigation
Kılıççı, Çetin
Şanverdi, İlhan
Darıcı, Ezgi
Özkaya, Enis
Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title_full Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title_fullStr Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title_full_unstemmed Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title_short Laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
title_sort laparoscopic vaginal bead pull-through vaginoplasty technique using dental prosthesis material
topic Clinical Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7538826/
https://www.ncbi.nlm.nih.gov/pubmed/33072422
http://dx.doi.org/10.4274/tjod.galenos.2020.39112
work_keys_str_mv AT kılıccıcetin laparoscopicvaginalbeadpullthroughvaginoplastytechniqueusingdentalprosthesismaterial
AT sanverdiilhan laparoscopicvaginalbeadpullthroughvaginoplastytechniqueusingdentalprosthesismaterial
AT darıcıezgi laparoscopicvaginalbeadpullthroughvaginoplastytechniqueusingdentalprosthesismaterial
AT ozkayaenis laparoscopicvaginalbeadpullthroughvaginoplastytechniqueusingdentalprosthesismaterial