Cargando…

Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report

BACKGROUND: The evolution of remote systems and artificial intelligence technology has led to increase in robotic surgeries. One system used in this case report is the Senhance robotic system. The most important premise for using robotic surgery in cancer therapeutics is to ensure oncological safety...

Descripción completa

Detalles Bibliográficos
Autores principales: Kataoka, Atsuko, Hirano, Yasumitsu, Kondo, Hiroka, Shimamura, Satoshi, Kataoka, Masahiro, Asari, Masahiro, Fujii, Takatsugu, Ishikawa, Shintaro, Ishii, Toshimasa, Yamaguchi, Shigeki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7539249/
https://www.ncbi.nlm.nih.gov/pubmed/33026545
http://dx.doi.org/10.1186/s40792-020-01037-y
_version_ 1783591023111307264
author Kataoka, Atsuko
Hirano, Yasumitsu
Kondo, Hiroka
Shimamura, Satoshi
Kataoka, Masahiro
Asari, Masahiro
Fujii, Takatsugu
Ishikawa, Shintaro
Ishii, Toshimasa
Yamaguchi, Shigeki
author_facet Kataoka, Atsuko
Hirano, Yasumitsu
Kondo, Hiroka
Shimamura, Satoshi
Kataoka, Masahiro
Asari, Masahiro
Fujii, Takatsugu
Ishikawa, Shintaro
Ishii, Toshimasa
Yamaguchi, Shigeki
author_sort Kataoka, Atsuko
collection PubMed
description BACKGROUND: The evolution of remote systems and artificial intelligence technology has led to increase in robotic surgeries. One system used in this case report is the Senhance robotic system. The most important premise for using robotic surgery in cancer therapeutics is to ensure oncological safety. Similar to conventional laparoscopic surgery, robotic surgery needs to be a reliable and secure surgical procedure, such as complete mesocolic excisions with central vascular ligations in Western countries or D3 lymph node dissections (dissection of the lymph nodes that locates from the origin to the terminal branch of the main feeding artery of cancer) in Japan. CASE PRESENTATION: A 76-year-old man underwent clinical examination for severe anemia. He was diagnosed with transverse colon cancer of tumor (T)3, node (N)1a, metastasis (M)0 cancer stage IIIA. A right hemicolectomy with D3 lymph node dissection using the Senhance surgical system was performed. The operative time was 313 min and the estimated blood loss was 5 ml. He was discharged from our hospital 12 days after the surgery without any complications. What is the remarkable of this report, not only mobilization of right colon but also D3 lymph node dissection and vascular ligation were performed intraperitoneally by using Senhance robotic system as conventional laparoscopic surgery. We tried using fourth robotic arm to accomplish lymphadenectomies and middle colic artery dissection. A right hemicolectomy with D3 dissection using the Da Vinci surgical system was reported. Another report of a right hemicolectomy performed with the Senhance robotic system was identified; however, in that study, lymph node dissections were not performed intraperitoneally. CONCLUSIONS: Therefore, to our knowledge, this is the first report using the Senhance robotic system for right hemicolectomy with D3 dissection. We hope that our case report will assist in the establishment of this robotic procedure in surgical practice.
format Online
Article
Text
id pubmed-7539249
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-75392492020-10-19 Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report Kataoka, Atsuko Hirano, Yasumitsu Kondo, Hiroka Shimamura, Satoshi Kataoka, Masahiro Asari, Masahiro Fujii, Takatsugu Ishikawa, Shintaro Ishii, Toshimasa Yamaguchi, Shigeki Surg Case Rep Case Report BACKGROUND: The evolution of remote systems and artificial intelligence technology has led to increase in robotic surgeries. One system used in this case report is the Senhance robotic system. The most important premise for using robotic surgery in cancer therapeutics is to ensure oncological safety. Similar to conventional laparoscopic surgery, robotic surgery needs to be a reliable and secure surgical procedure, such as complete mesocolic excisions with central vascular ligations in Western countries or D3 lymph node dissections (dissection of the lymph nodes that locates from the origin to the terminal branch of the main feeding artery of cancer) in Japan. CASE PRESENTATION: A 76-year-old man underwent clinical examination for severe anemia. He was diagnosed with transverse colon cancer of tumor (T)3, node (N)1a, metastasis (M)0 cancer stage IIIA. A right hemicolectomy with D3 lymph node dissection using the Senhance surgical system was performed. The operative time was 313 min and the estimated blood loss was 5 ml. He was discharged from our hospital 12 days after the surgery without any complications. What is the remarkable of this report, not only mobilization of right colon but also D3 lymph node dissection and vascular ligation were performed intraperitoneally by using Senhance robotic system as conventional laparoscopic surgery. We tried using fourth robotic arm to accomplish lymphadenectomies and middle colic artery dissection. A right hemicolectomy with D3 dissection using the Da Vinci surgical system was reported. Another report of a right hemicolectomy performed with the Senhance robotic system was identified; however, in that study, lymph node dissections were not performed intraperitoneally. CONCLUSIONS: Therefore, to our knowledge, this is the first report using the Senhance robotic system for right hemicolectomy with D3 dissection. We hope that our case report will assist in the establishment of this robotic procedure in surgical practice. Springer Berlin Heidelberg 2020-10-07 /pmc/articles/PMC7539249/ /pubmed/33026545 http://dx.doi.org/10.1186/s40792-020-01037-y Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Case Report
Kataoka, Atsuko
Hirano, Yasumitsu
Kondo, Hiroka
Shimamura, Satoshi
Kataoka, Masahiro
Asari, Masahiro
Fujii, Takatsugu
Ishikawa, Shintaro
Ishii, Toshimasa
Yamaguchi, Shigeki
Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title_full Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title_fullStr Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title_full_unstemmed Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title_short Right hemicolectomy with D3 lymph node dissection for right-sided transverse colon cancer using the Senhance robotic system: a case report
title_sort right hemicolectomy with d3 lymph node dissection for right-sided transverse colon cancer using the senhance robotic system: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7539249/
https://www.ncbi.nlm.nih.gov/pubmed/33026545
http://dx.doi.org/10.1186/s40792-020-01037-y
work_keys_str_mv AT kataokaatsuko righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT hiranoyasumitsu righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT kondohiroka righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT shimamurasatoshi righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT kataokamasahiro righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT asarimasahiro righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT fujiitakatsugu righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT ishikawashintaro righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT ishiitoshimasa righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport
AT yamaguchishigeki righthemicolectomywithd3lymphnodedissectionforrightsidedtransversecoloncancerusingthesenhanceroboticsystemacasereport